My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7505 SEAWAY BLVD 2022-05-13
>
Address Records
>
SEAWAY BLVD
>
7505
>
7505 SEAWAY BLVD 2022-05-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2022 4:20:04 PM
Creation date
6/4/2020 10:42:00 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
7505
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
660
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLANS. SPECIFICATIONS AND ESTIMATE REVIEW <br />Project Title: <br />75th — Seaway Transit Center 90% Review <br />Job Charge: <br />Reviewed By: <br />Office & Mail Stop: <br />Phone: <br />Date: <br />Sheet <br />WO# <br />Euneka Richards, Kirk <br />Traffic Operations <br />425-257-8926 <br />2-8-17 <br />7 <br />Brooks, Corey Hert, <br />Erik Emerson <br /># <br />ShVPg <br />Reviewer's Comment <br />Designer's Response <br />Init. <br />48 <br />Special <br />Everett Special Provisions are in addition to the WSDOT Standard <br />Section 344113 Part 1.06A, referencing <br />BAJ <br />Provisions <br />Specifications, please either confirm where this is clarified in the specs such <br />SUBMITTALS, revised to read as <br />Sec <br />that we know what WSDOT section this is supplementing or add the text: <br />"Submittals will be made in accordance with <br />344113 <br />"WSDOT Section 9-29.6 is supplemented with the following:" preceding the <br />the requirements of Section 013300 — <br />Part 1.0613 <br />text for section 1.06B #2. <br />Submittal procedures, and Section 8- <br />20.2 1 of the Standard Specifications." <br />49 <br />Special <br />Please change section 1.06B #2 to say" Manufacturer's complete <br />Section 344113 Part 1.06B, referencing <br />BAJ <br />Provisions <br />Specifications for all traffic signal system components including but not <br />SUBMITTALS, revised as requested. <br />Sec <br />limited to" and then insert the full text from the attached file "CNH 8-20.2(1) <br />344113 <br />Equipment List and Drawings" part B) (lines 13 to 31). <br />Part 1.06B <br />50 <br />Special <br />Please add the text of the attached file "CNH 8-20.2(9-29.1) Conduit" in its <br />Section 344113 Part 2.04, referencing <br />BAJ <br />Provisions <br />entirety to part 2.04. If there are contradictions with the existing text, the <br />CONDUITS, revised as requested. <br />Sec <br />Everett Special Provision should be followed. <br />344113 <br />Part 2.04 <br />51 <br />Special <br />Please replace the text in part 2.05 with the text of the attached file "CNH 8- <br />Section 344113 Part 2.05, referencing <br />BAJ <br />Provisions <br />20.2(9-29.2) Junction Box" in its entirety. <br />JUNCTION BOXES, revised as requested. <br />Sec <br />344113 <br />Part 2.05 <br />52 <br />Special <br />Please replace the text in part 2.06 and part 2.07 with the text of the <br />Section 344113 Part 2.07, revised to <br />BAJ <br />Provisions <br />attached files "CNH 8-20.2(9-29.3(2)) Detector Cable, CNH 8-20.2(9-29.3(2)) <br />reference LOOP DETECTOR LEAD-IN <br />Sec <br />Loop Wire, and CNH 8-20.3(14)C Induction Loops" as needed but be very <br />CABLE (rather than INDUCTION LOOPS). <br />344113 <br />aware that Everett Loops Installation, specs, and splicing is very different <br />Section 344113 Part 2.06, referencing , <br />Part 2.06 <br />from WSDOT standards. See all attached Everett Special Provisions to find <br />ELECTRICAL SPLICE MATERIALS, <br />and Part <br />appropriate specs for this area. <br />deleted. Incorporated Everett 8-20.2(9- <br />2 07 <br />29.3(2)) Detector Cable and Loop Wire <br />specs. Deferred incorporation of Everett 8- <br />90% Seaway Review Comments.docxx l <br />
The URL can be used to link to this page
Your browser does not support the video tag.