Laserfiche WebLink
PLANS, SPECIFICATIONS AND ESTIMATE REVIEW <br />Project Title: <br />75th — Seaway Transit Center 90% Review <br />Job Charge: <br />Reviewed By: <br />Office & Mail Stop: <br />Phone: <br />Date: <br />Sheet <br />WO# <br />Corey Hart <br />Public Works <br />425-257-8887 <br />2-16-17 <br />1 <br /># <br />Sht/Pg <br />Reviewer's Comment <br />Designer's Response <br />Init. <br />74 <br />PV1 <br />Add dotted extension lines — see markup <br />Added <br />VWW <br />75 <br />PV1 <br />On the northbound right -side left -turn lane on Seaway Blvd, move stop bar <br />Edit does not match existing channelization <br />VWW <br />back to match left -side left -turn lane. — see markup <br />on Seaway Blvd. Adjusted per City <br />recommendation. <br />76 <br />PV1 <br />All pavement marking on 75th St SW is to be Type D MMA — see markup <br />Added General Note 7 <br />VWW <br />77 <br />PV1, PV2, <br />Const. Note 17, change "Painted" to "Profiled Plastic". — see markup <br />Changed <br />VWW <br />PV3 <br />78 <br />PV1, PV2, <br />Const. Note 18,19 and 26, change "Painted" to "Plastid'— see markup <br />Changed <br />VWW <br />PV3 <br />79 <br />PV2 <br />On concrete, especially green concrete, strongly recommend MMA — see <br />Added General Note 7 <br />VWW <br />markup <br />80 <br />PV4 <br />All pavement markings on Seaway are Type D MMA. 2W and 2YY RPM's <br />Added General Note 7. Added verbiage to <br />VWW <br />are also required on skip line and yellow CL. <br />Const. Note 18 and new Const. Note 35. <br />81 <br />PV4 <br />Add Const. Note 25. — see markup <br />Added "ONLY" lettering w/ Const. Note 25 <br />VWW <br />82 <br />PV4 <br />Drop wide line — see markup <br />Replaced line with Wide Dotted Lane Line <br />VWW <br />w/ new Const. Note 35. <br />83 <br />PV4 <br />Add Lane widths — see markup <br />Added <br />VWW <br />84 <br />PV4 <br />On the northbound right -side left -turn lane on Seaway Blvd, move stop bar <br />Edit does not match existing channelization <br />VWW <br />back to match left -side left -turn lane. — see markup <br />on Seaway Blvd. Adjusted per City <br />recommendation. <br />85 <br />PV4 <br />Add plastic dotted extension lines — see markup <br />Added <br />VWW <br />86 <br />PV4 <br />Const. Note 6, change "thermal plastic" to "Type D Plastic" <br />Changed <br />VWW <br />87 <br />PV4 <br />Const. Note 17 and 18, change "Painted" to "Profiled Plastic". — see markup <br />Changed <br />VWW <br />88 <br />PV4 <br />Const. Note 19 and 26, change "Painted" to "Plastic" — see markup <br />Changed <br />VWW <br />89 <br />SG1 <br />Is there a reason why storm is not being adjusted? — see markup <br />The intent is to have water drain away from <br />DCS <br />the curb line to a valley so transitusers do <br />i. <br />not get wet. <br />90% Seaway Review Comments.docxx <br />