Laserfiche WebLink
October 14, 2015 <br /> Project No.T-6116-2 <br /> oundwater seepage should be anticipated within excavations during the wet winter season. We anticipate that <br /> the volume of water and rate of flow into the excavation will be relatively minor and are not expected to impact <br /> the stability of the excavations when completed, as described. Conventional sump pumping procedures, along <br /> with a system of collection trenches, if necessary should be capable of maintaining a relative dry excavation for <br /> construction purposes. <br /> The above information is provided solely for the benefit of the owner and other design consultants, and should not <br /> be construed to imply that Terra Associates, Inc. assumes responsibility for job site safety. It is understood that <br /> job site safety is the sole responsibility of the project contractor. <br /> Shoring <br /> The detention vault is located within seven feet of the southern property line. Based on the drawings, the <br /> excavation depth to achieve the foundation elevation of 540.5 is between 9 and 19 feet. These depths cannot be <br /> achieved using conventional excavation techniques unless an excavation easement with the adjacent property <br /> owners is obtained. If the excavation easement cannot be obtained, the excavation will need to use temporary <br /> shoring. Based on the limited height, a conventional cantilevered soldier pile shoring with timber lagging would <br /> be the most cost effective shoring system, in our opinion. Recommended soil parameters for design of the <br /> shoring are shown on attached Figure 3. Drilling obstructions, such as boulders, may also be encountered in the <br /> native soils. Caving or collapse of opened drilled shafts may occur. The contractor must be prepared to case the <br /> —illed shafts, as needed,to prevent collapse and maintain a relatively clean,open hole. <br /> 5.4 Foundations <br /> The building may be supported on conventional spread footings bearing on competent native soils or on structural <br /> fill placed above competent native soils. Foundation sub_ :de should be prepared as recommended in Section 5.2 <br /> of this report. Perimeter foundations exposed to the weather should bear at a minimum depth of 18 inches below <br /> final exterior grades. Interior foundations can be constructed at any convenient depth below the floor slab. <br /> Foundations can be dimensioned for a net allowable bearing capacity of 3,000 pounds per square foot(psf). For <br /> short-term loads, such as wind and seismic, a one-third increase in this allowable capacity can be used. With <br /> structural loading as anticipated and this bearing stress applied,estimated total settlements are less than one-inch. <br /> For designing foundations to resist lateral loads, a base friction coefficient of 0.4 can be used. Passive earth <br /> pressure acting on the sides of the footings may also be considered. We recommend calculating this lateral <br /> resistance using an equivalent fluid weight of 350 pounds per cubic foot(pcf). We recommend not including the <br /> upper 12 inches of soil in this computation because they can be affected by weather or disturbed by future grading <br /> activity. This value assumes the foundations will be constructed neat against competent native soil or backfilled <br /> with structural fill, as described in Section 5.2 of this report. The recommended values include a safety factor of <br /> 1.5. <br /> Page No. 8 <br />