Laserfiche WebLink
HEC-22 Energy Grade Line Computation Sheet-Table A <br /> Downstream Upstream upstream <br /> Struct ID D(ft) Q(cfs) L(ft) BOCi BOC, S(ft/ft) d(ft) d.(ft) v2/2g EGLo(ft) HGLo(ft) Step 8 St(ft/ft) Total Pipe EGL;(ft) HGL;(ft) E.(table EGLa(ft) U/S TOC <br /> Upstream invert invert (ft) Loss(table B) B)(ft) (ft) <br /> Upstream down- (ft) <br /> stream <br /> (1) (2) (3) (4) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) (17) <br /> Outlet Pipe 420.9 421.9 <br /> - <br /> CB 2 1 1.26 70 421.00 420.90 0.0014 0.72 0.47 0.07 421.69 421.62 subcritical 0.00140 0.098 421.79 421.72 0.802 421.80 422 <br /> CB 3 1 1.12 64 421.19 421.00 0.0029 0.52 0.45 0.11 421.86 421.75 subcritical 0.00290 0.186 422.05 421.94 0.878 422.07 422.19 <br /> CB 4 1 0.90 268 421.96 421.19 0.0029 0.46 0.4 0.1 422.13 422.03 subcritical 0.00290 0.777 422.91 422.81 0.967 422.93 422.96 <br /> CB 10 1.25 0.77 28 421.82 421.71 0.004 0.35 0.34 0.11 423.02 422.91 subcritical 0.00400 0.112 423.13 423.02 1.334 423.15 423.07 <br /> CB 11 1.25 0.73 30 421.93 421.82 0.0037 0.35 0.33 0.19 423.23 423.04 na 0.00011 0.003 423.23 423.04 1.341 423.27 423.18 <br /> CB 12 1.25 0.72 85 422.32 421.93 0.0046 0.33 0.33 0.23 423.36 423.13 na 0.00011 0.009 423.37 423.14 1.098 423.42 423.57 <br /> CB 5 1 0.69 27 422.65 422.57 0.0034 0.38 0.35 0.1 423.49 423.39 subcritical 0.00340 0.092 423.58 423.48 0.952 423.60 423.65 <br /> CB 13 1.25 0.54 131 424.04 422.40 0.0125 0.22 0.29 0.21 423.9 423.69 supercritical NA 0.000 424.47 424.26 0.430 424.47 425.29 <br /> CB 70 1.25 0.50 44 424.65 424.04 0.0139 0.21 0.28 0.21 424.67 424.46 supercritical NA 0.000 425.07 424.86 0.420 425.07 425.9 <br /> CB 14 1 0.38 73 425.95 424.90 0.0144 0.19 0.25 0.2 425.29 425.09 supercritical NA 0.000 426.34 426.14 0.390 426.34 426.95 <br /> CB 6 0.67 0.37 104 427.57 426.28 0.0124 0.23 0.28 0.19 426.7 426.51 supercritical NA 0.000 427.99 427.80 0.420 427.99 428.24 <br /> MCOB, Phase II <br /> Calculation C-2 <br /> WEIR WALL HEIGHT Page 7 <br />