My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7000 HARDESON RD Geotech Report 2022-10-25
>
Address Records
>
HARDESON RD
>
7000
>
Geotech Report
>
7000 HARDESON RD Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 1:31:51 PM
Creation date
6/5/2020 2:03:52 PM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
7000
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Geotechnical Engineering Report <br /> Community Transit Merrill Creek Operating Base <br /> 7100 Hardeson Road <br /> Everett, Washington <br /> February 28, 2018 <br /> RN File No, 3224-002A <br /> Page 7 <br /> For planning purposes, we recommend that temporary cuts in the near-surface fill soils be no <br /> steeper than 1.5 Horizontal to 1 Vertical (1.5H:1V), If groundwater seepage is encountered, we <br /> expect that flatter inclinations would be necessary. <br /> We recommend that cut slopes be protected from erosion. Measures taken may include <br /> covering cut slopes with plastic sheeting and diverting surface runoff away from the top of cut <br /> slopes. We do not recommend vertical slopes for cuts deeper than 4 feet, if worker access is <br /> necessary. We recommend that cut slope heights and inclinations conform to local and <br /> WISHAIOSHA standards, <br /> Drainage <br /> We recommend that runoff from the pavement be collected and routed to an appropriate storm <br /> water discharge system. The finished ground surface should be sloped at a gradient of 5 <br /> percent minimum for a distance of at least 10 feet away from the buildings, or to an approved <br /> method of diverting water from the foundation, per iBC Section 1804.4. Surface water should <br /> be collected by permanent catch basins and drain lines, and be discharged into a storm drain <br /> system. We have reviewed the Storm Drainage Plan and Details on plan sheets SD11 and <br /> SDD04. In our opinion, the 4-inch diameter perforated PVC pipe is spaced at appropriate <br /> intervals to be sufficient to prevent water from ponding on the surface of the pavement. <br /> Infiltration and Dispersion <br /> We understand that the City of Everett has adopted the 2014 Department of Ecology <br /> Stormwater Management Manual for Western Washington (DOE). The manual presents Best <br /> Management Practices(BMPs) that can be implemented to meet the project Minimum <br /> Requirements. The manual also refers to the 2012 Low Impact Development Technical <br /> Guidance Manual for Puget Sound (LID) for further design criteria of these BMPs. We <br /> understand the project is subject to Minimum Requirements #1 through #5. <br /> Minimum Requirement#5 requires BMPs be considered in the order listed in List#1 in Volume <br /> 1 of the DOE. List#1 presents BMPs to consider for Lawn and Landscaped Areas, Roofs and <br /> Other Hard Surfaces. Since this is a pavement rehabilitation project, we are addressing only the <br /> `Other Hard Surfaces' section. These BMPs include Full Dispersion, Permeable Pavement, Rain <br /> Gardens, Bioretention and Sheet Flow Dispersion. We address the infeasibility criteria for each <br /> BMP below. <br /> Full Dispersion BMP T5.30: According to DOE Section 5.3 of Volume V, "Full dispersion <br /> applies to sites (or sub-areas of sites) with a maximum of 10% effective impervious area that is <br /> dispersed through 65% of the site maintained in natural vegetation." With the exception of a <br /> few landscaped islands, the site is covered with impervious surface and does not meet the <br /> required percentage of native vegetated surface. In addition, the minimum design requirements <br /> for residential projects section on page 5-34 of Volume V states "Runoff must be dispersed into <br /> the native area in accordance with one or more of the dispersion devices, and in accordance <br /> with the design criteria and limits for those devices, cited in this BMP. A native vegetation <br /> flowpath of at least 100 feet in length (25 for sheet flow from a non-native pervious surface) <br /> Robinson Noble, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.