My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3315 SEAWAY BLVD 2020-06-05
>
Address Records
>
SEAWAY BLVD
>
3315
>
3315 SEAWAY BLVD 2020-06-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2020 3:23:08 PM
Creation date
6/5/2020 3:18:13 PM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
3315
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
195
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ms. Nadia Azarova <br /> Craft Architects <br /> Plan Check Number: B1808-012, First Review <br /> October 1, 2018 <br /> Structural <br /> General: <br /> 1. It is understood per discussions with the project architect that the design for the area between <br /> Grids E.3-F.6/2.9-4.6 may be revised. The architect has indicated the area will-be revised to <br /> provide an independent structure with a 125 psf storage area above the office/laboratory <br /> space. Structural drawings showing the revised construction of this area should be submitted <br /> for review. Criteria for the design of the structure, including but not limited to the proposed <br /> lateral system, shall be stated in the Structural General Notes on Sheet S1.0. Based on the <br /> proposed storage loading, it is presumed that the 6-inch slab may not be sufficient for the <br /> revised design and should be provided with new foundations as needed. At least two columns <br /> for the existing building are located within the footprint for the proposed independent <br /> structure; the columns should be seismic isolated from the structure. Calculations <br /> substantiating the design of the structure should be submitted for review. Additional <br /> comments may be provided pending the review for this portion of the project. See IBC <br /> Sections 1603.1, 1603.1.5, 1604.1, 1604.1, and 1613.1,and ASCE 7-10 Sections 12.12.3. <br /> Gravity System: <br /> 2. Sheet A2.4 indicates that the Second Floor will include blackout curtains. The structural plans <br /> do not appear to include framing to support the curtain. The support requirements for the <br /> curtains should be clarified. Drawings and calculations for supplemental framing should be <br /> submitted for review as needed. The calculations should evaluate the existing roof structure to <br /> support the additional loads as needed. See IBC Sections 1603.1 and 1604.1. <br /> Lateral System: <br /> 3. The lateral forces for the mezzanine are calculated on page 2. See IBC Section 1613.1 and <br /> ASCE 7-10 Section 12.7.2. The following comments should be addressed: <br /> a. The exterior tilt-up concrete walls include an architectural stud framed wall. The wall <br /> weight should be increased. <br /> b. The mezzanine area appears to include interior partition walls. The floor seismic weight <br /> should be increased to 32 psf to include the 10 psf partition weight. <br /> 4. Note 3/S2.1 specifies that the sheathing nailing is 0.131" nails (i.e.,8d). Calculations page 5 <br /> considers 0.148"nails (i.e., 10d). Note 3 should be revised. In addition, verify that the grade <br /> of the truss top chords is equal or greater to DF-L. See IBC Section 2306.1 and AWC SDPWS- <br /> 15 Table 4.2C including Footnote 2. <br /> 5. The diaphragm has been designed to span in the east-west direction between shear walls on <br /> Grids F.6 and G.9 per calculation page 5. The diaphragms provide out-of-plane support to the <br /> concrete wall panels and include one half of the wall height in the effective seismic weight for <br /> the diaphragm. Based on the relatively shorter height of the mezzanine level and shorter span <br /> of the mezzanine diaphragm, in comparison with the roof diaphragm, it appears that the <br /> mezzanine level may result in a substantially-stiffer lateral load path that attracts additional <br /> seismic weight from both the panels and potentially the roof diaphragm. A stiffness analysis of <br /> (Page 3 ofiTh <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8810 • Fax(425) 257857 <br />
The URL can be used to link to this page
Your browser does not support the video tag.