My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3315 SEAWAY BLVD 2020-06-05
>
Address Records
>
SEAWAY BLVD
>
3315
>
3315 SEAWAY BLVD 2020-06-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2020 3:23:08 PM
Creation date
6/5/2020 3:18:13 PM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
3315
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
195
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Drew Martin <br /> From: Drew Martin <br /> Sent: Thursday, November 8, 2018 3:06 PM <br /> To: 'Nadia Azarova' <br /> Subject: RE: City of Everett Public Works: 3315 Seaway Blvd (B1808-012) <br /> Nadia, <br /> Here are my final comments for my review of the resubmittal documents. Regarding loading of the TAT area, in addition <br /> to comments for the future use of this area,we will require the drawings to identify this area as not usable for occupied <br /> or storage space under this permit. We can redline or let you revise the drawings. If the latter, I will specify the <br /> locations where this note needs to occur. <br /> Please have the structural engineer address the following comments regarding the TAT design (reference original <br /> Structural Comment 1). Based on the number of issues discussed below, please have the EOR provide an itemized <br /> response to each part clearly indicating how the comment has been addressed. This should also be done for comments <br /> forward in the previous emails (attached below). <br /> 1. The following comments should be addressed: <br /> a. Documentation substantiating the 18 psf dead load should be submitted for review. Note that this <br /> value is less than used for the other mezzanines(i.e., 18 psf per page 1 of the calculations dated <br /> 07/18/18) supporting equal or lesser live loads. <br /> b. Continuing with the previous comment,the dead load should include a 4 psf HVAC load per ASCE 7-10 <br /> Table C3-1. Note that this comment is presuming the HEPA filter system is separate from the HVAC <br /> system. <br /> c. The seismic mass includes only 25%of the mechanical system weight. The full weight of the mechanical <br /> systems shall be included. See ASCE 7-10 Section 12.7.2 Item 3. Note that it is not clear if the weight is <br /> equipment or storage, or both. If both, separate weight components shall be specified. A drawing <br /> depicting the weight equipment, including component weights, sizes, and locations, shall be submitted <br /> for review. <br /> d. Continuing with the previous comment,the design loads on Sheet S1.0 shall clearly distinguish the <br /> design loads for storage and permanent equipment. <br /> e. The tributary wall mass to the structural lid only include the longitudinal walls. The mass should be <br /> increased to include the transverse walls. Note that a weight estimate of wall Types 2 and 12 per Sheet <br /> A8 appears to exceed 10 psf. Architect to verify that Wall Type 12 should include GWB on both sides <br /> similar to other wall types. <br /> f. It is not clear if the 125 psf load represents both permanent equipment and storage loads. Where either <br /> load is not equally distributed across the structural lid,the weights shall be effectively loaded to the wall <br /> lines support the associated lateral seismic load. Non-uniformly distributed loads shall not be uniformly <br /> distributed to all wall lines. <br /> g. The limited wall length on Grid 4.4 is only 7 feet long, not 9'-10" per page T-6. <br /> h. Page T-6 includes a 4' tributary roof width resisting overturning for the walls on Grids 4.4 and 3. Based <br /> on the joist spacing of 16" per Sheet 52.1,the tributary width is only 8". The resisting weight shall be <br /> reduced. <br /> i. The shear wall holdown design shall be revised. The earthquake component shall be increased per the <br /> provisions of ACI 318-14 Section 17.2.3.4.3. The design load shall be calculated per ASCE 7-10 Section <br /> 12.4.3.2 Equation 7: a)the overstrenght factor shall apply to the earthquake component, not the net <br /> uplift force after reduction by gravity loads; and b)the vertical seismic load effect per Section 12.4.2.2 <br /> shall be included in the design load. Note tha_Ltke uplift forces have been calculated using ASD load <br /> 09, <br />
The URL can be used to link to this page
Your browser does not support the video tag.