My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8417 EVERGREEN WAY PANDA EXPRESS 2022-05-23
>
Address Records
>
EVERGREEN WAY
>
8417
>
PANDA EXPRESS
>
8417 EVERGREEN WAY PANDA EXPRESS 2022-05-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2022 7:24:40 AM
Creation date
6/15/2020 2:50:39 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8417
Tenant Name
PANDA EXPRESS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
174
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J <br /> LMR <br /> Consulting Mechanical Engineers Tel: 1-510-733-2330 <br /> 1165 A Street, Hayward, CA 94541 Fax: 1-510-733-0332 <br /> August 15, 2019 Ref. No. 1891-3.Itr <br /> e'-1 <br /> City of Everett <br /> Attn: MR. Drew Martin <br /> Project: Panda Express <br /> 3200 Cedar Street, 2nd Floor <br /> Everett, WA 98201 <br /> Mr. Martin, <br /> The following are the City of Everett plan check comments for the review,with the associated responses. <br /> 1. Submit two new copies of the mechanical drawings with the hood information removed. The following list of <br /> sheets pertaining to the hoods is based on our review, but shall be verified by the applicant: M-400, M-401, <br /> M-500. All information associated with the mechanical hoods shall be removed from other sheets. See Note <br /> 22/M-100 and Section 3/M-501. Once again,these are offered as examples and not a comprehensive list. <br /> The applicant shall verify all hood information is removed. <br /> Response: The hood information removed or noted as reference only in mechanical set of <br /> drawings.Please refer to sheet M-000, M-100,M-401& M-501. The sheets <br /> M-400&M-500 removed from the mechanical set. <br /> 2. RTU-1, RTU-2,and RTU-3 are already included in Permit No. M1908-008. They shall be removed from the <br /> mechanical drawings. They should be depicted on Sheet M-100 but identified for reference only. The RTU- <br /> schedule on Sheet M-000 should be removed. <br /> Response: RTU-1,RTU-2 and RTU-3 removed or noted as reference only in mechanical set of <br /> drawings. Need to include for air balancing purpose.Please refer to sheet M-000 <br /> &M-100. <br /> 5. Submit a separate application for the hoods, including separate drawing sets. <br /> Response: The hood information has been removed from the mechanical set. The hood <br /> information shown in a separate drawing set, marked as HOOD SET in the title <br /> block. <br /> 6. Verify that the hoods are Type I. Based on this being a restaurant preparing food, it seems that the hoods <br /> should be Type I unless they meet the Type II definition per IMC Section 202"Hoods:Type II"and Section <br /> 507.3. Note that Note 22/M-100 identifies grease duct cleanouts and Sections 18/M-500 identifies the <br /> equipment under the hoods as"cooking equipment". <br /> Response: The hoods noted as TYPE 1 GREASE HOOD. Please refer to Hood Set, <br /> Mechanical Specifications 1/M-000;Mechanical Key Notes 1/M-100&Detail 18/M- <br /> 500. <br /> 7. The hood drawings shall show all connection requirements between the hoods and the supporting structure. <br /> The hoods shall be provided with lateral bracing in addition to gravity support. <br /> Response: Lateral bracing in addition to gravity support provided to the hoods. Please refer <br /> to Hood Set, details 137M-500, 14/M-500, 18/M-500&3/M-501. <br />
The URL can be used to link to this page
Your browser does not support the video tag.