My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8417 EVERGREEN WAY PANDA EXPRESS 2022-05-23
>
Address Records
>
EVERGREEN WAY
>
8417
>
PANDA EXPRESS
>
8417 EVERGREEN WAY PANDA EXPRESS 2022-05-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2022 7:24:40 AM
Creation date
6/15/2020 2:50:39 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8417
Tenant Name
PANDA EXPRESS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
174
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'Drew Martin <br /> From: Drew Martin <br /> Sent: Wednesday,August 7, 2019 1:54 PM <br /> To: Mark Mcllvain <br /> Cc: 'Lupe Sandoval'; 'tammirdg@aol.com'; Cindy Bergsma <br /> Subject: City of Everett Permit Services: 8417 Evergreen Way(M1908-009) <br /> Mark, <br /> This permit is for additional mechanical units and ductwork in the Panda Express space. The drawings include sheets for <br /> (2)Type II hoods. Type II (and Type I) hoods need must be submitted separately under their own permit <br /> application. The following provides direction and preliminary comments; a full review of the submittal documents will <br /> not be performed until the submittal issues are addressed as listed below. <br /> Please address the following: <br /> 1. Submit two new copies of the mechanical drawings with the hood information removed. The following list of <br /> sheets pertaining to the hoods is based on our review, but shall be verified by the applicant: M-400, M-401, M- <br /> 500. All information associated with the mechanical hoods shall be removed from other sheets. See Note <br /> 22/M-100 and Section 3/M-501. Once again,these are offered as examples and not a comprehensive list. The <br /> applicant shall verify all hood information is removed. <br /> 2. RTU-1, RTU-2, and RTU-3 are already included in Permit No. M1908-008. They shall be removed from the <br /> mechanical drawings. They should be depicted on Sheet M-100 but identified for reference only. The RTU- <br /> schedule on Sheet M-000 should be removed. <br /> 3. The applicant shall verify that the unit weights specified in the mechanical drawings do not exceed the design <br /> values specified in the previously approved building (i.e.,structural) drawings under Permit No. B1805-010). <br /> 4. Provide a revised valuation for the mechanical permit. It is presumed that the current valuation includes the <br /> hoods,which should be removed. <br /> 5. Submit a separate application for the hoods, including separate drawing sets. <br /> 6. Verify that the hoods are Type I. Based on this being a restaurant preparing food, it seems that the hoods <br /> should be Type I unless they meet the Type II definition per IMC Section 202 "Hoods:Type II" and Section <br /> 507.3. Note that Note 22/M-100 identifies grease duct cleanouts and Sections 18/M-500 identifies the <br /> equipment under the hoods as"cooking equipment". <br /> 7. The hood drawings shall show all connection requirements between the hoods and the supporting <br /> structure. The hoods shall be provided with lateral bracing in addition to gravity support. <br /> 8. Detail 5/M-500 indicates the fire wrap to extend 18" above combustible material, but does not show this <br /> consistently, nor is it consistent in Details 18/M-500 and 3/M-501. Other details should similarly be <br /> reviewed. All details shall consistently show the requirement. <br /> 9. Detail 5/M-500 states to provide a hinge and flexible electrical cable. The detail shall also require a restraint per <br /> IMC 506.5.3. <br /> 10. Verify the hoods have the required clearance to combustible construction. Detail 18/M-500 appears to indicate <br /> metal stud framing, but the construction drawings consist of wood stud framing. <br /> _ Drew Martin,P.E.,S.E. <br /> Associate Engineer—Commercial Plans Examiner I Permit Services <br /> LNBi <br /> 425.257.8813 I 3200 Cedar Street, 2nd Floor, Everett,WA 98201 <br /> EVERETT Hours: Monday—Friday 7:30am-12:OOpm and 1:OOpm-4:OOpm <br /> everettwa.gov I Facebook I Twitter <br /> 1 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.