My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8417 EVERGREEN WAY PANDA EXPRESS 2022-05-23
>
Address Records
>
EVERGREEN WAY
>
8417
>
PANDA EXPRESS
>
8417 EVERGREEN WAY PANDA EXPRESS 2022-05-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2022 7:24:40 AM
Creation date
6/15/2020 2:50:39 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8417
Tenant Name
PANDA EXPRESS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
174
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> September 16, 2019 lierracan <br /> CFT NV Developments, LLC <br /> 1683 Walnut Grove Avenue <br /> Rosemead, CA 91770 <br /> Attn: Charlie Shen <br /> P: 626.799.9898 <br /> E: Charlie.shen@pandarg.com <br /> Re: Responses to Plan Check Comments—First Building Review <br /> CFT Retail 8417b Evergreen Way <br /> Everett, Washington <br /> Dear Mr. Shen: <br /> We are supplying this letter to provide responses to City of Everett review comments provided to <br /> MCO Associates for Plan Check Number B1908-57, First Building Review dated September 10, <br /> 2019. Provided below are responses to geotechnical items provided in the plan check review. <br /> Comment: <br /> 1. The submittal documents for Permit No: B1805-010 include a geotechnical report prepared <br /> by Terracon, dated February 1, 2018. Section 4.6 states that"the proposed site <br /> development does not indicate for a retaining wall to be built", but appears to provide <br /> criteria for the design of site retaining walls. The geotechnical engineer shall provide a letter <br /> verifying that the design criteria provide in Section 4.6 is appropriate for the design of the <br /> proposed site retaining walls. Additional recommendations for the design of the walls shall <br /> be provided as needed. See IBC Sections 1803.2 and 1803.6. <br /> Response: <br /> Retaining walls have been added to the project since the time of the noted geotechnical report. <br /> Design criteria provided in Section 4.6 of our report would be applicable to design of these <br /> retaining walls.As noted in Section 4.2.3 of the report light compaction equipment should be used <br /> within a few feet of the back of the retaining wall. <br /> Comment: <br /> 2. Continuing with the previous comment, the retaining walls are located near existing <br /> buildings and parking surfaces that may place lateral surcharge pressures on the walls. <br /> Note that the wall section on page 14 schematically shows a surcharge load but does not <br /> specify values or a influence distance behind the wall. The.geotechnical engineer shall <br /> provide additional recommendations for surcharge loads as needed. See IBC Sections <br /> 1610.1, 1803.2, and 1803.6. <br /> Terracon Consultants, Inc. 21905 64th Avenue West Mountlake Terrace, WA 98043 <br /> P [425] 771 3304 F [425] 771 3549 terracon.com <br /> Geotechnical • Environmental ® Construction Materials ■ Facilities <br />
The URL can be used to link to this page
Your browser does not support the video tag.