My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8417 EVERGREEN WAY PANDA EXPRESS 2022-05-23
>
Address Records
>
EVERGREEN WAY
>
8417
>
PANDA EXPRESS
>
8417 EVERGREEN WAY PANDA EXPRESS 2022-05-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2022 7:24:40 AM
Creation date
6/15/2020 2:50:39 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8417
Tenant Name
PANDA EXPRESS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
174
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ms. Lupe Sandoval <br /> CRM Architects&Planners, Inc. <br /> Plan Check Number: B1805014, First Review <br /> January 10, 2019 <br /> Revisions to plans have been clouded with Delta 4. Please see Sheet G-001 revisions box <br /> for description. <br /> General: <br /> 1. No additional comment. <br /> 2. No additional comment. <br /> Fire Protection: <br /> 3. This comment has not been completely addressed. The original comment stated the <br /> stainless steel panel behind the Type 1 hoods shall extend at least 18 inches in all directions <br /> from the hood. See the Exception in IMC Section 507.2.6. The following comments shall be <br /> addressed: <br /> a. Detail 9/A-403 appears to show the steel panel located underneath an additional layer of <br /> 5/8"GWB. The panel shall be located over the GWB. <br /> Response: See revised Detail 9/A-403 with the stainless steel panel shown over the 5/8" <br /> Type X Gyp. Bd. <br /> b. Detail 6/A-404 appears to show the panels extending from the perimeter of the hood. <br /> The panels shall also be located behind the hood. <br /> Response: See revised Detail 6/A-404 with the stainless steel panel shown behind the hood. <br /> References to see Detail 9/A-403 have been added. <br /> c. Detail 9/A-403 specifies the wall framing as wood or metal studs. The wall construction <br /> shall be limited to non-combustible framing. The reference to wood studs shall be <br /> removed. See also Floor Plan 1/A-103 and Wall Types W1 and W5 on Sheet G-005. <br /> Response: See revised Detail 9/A-403 showing metal steel stud construction for wall. <br /> 4. This comment has not been completely addressed. Sheet A-105 states that the grease <br /> ducts have 1-hour wrap. Detail 5/M-500 specifies 2-hour wrap. The following comments <br /> shall be addressed: <br /> a. No additional comment. <br /> b. The wrap in Detail 5/M-500 shall extend at least 18-inches above all combustible <br /> materials (e.g., wood blocking, etc.). The detail specify the wrap to extend 18"above <br /> the roof, not the blocking. The clearance shall be provided above all combustible <br /> materials. See IBC Section 506.3.6. <br /> Response: See revised Sheet M-500 and LMR's response letter attached. <br /> O3200 Cedar Street O442255.225577.88800 goeverettwa. ov <br /> Everett,WA 98201 882 fax /7 everettwa. <br />
The URL can be used to link to this page
Your browser does not support the video tag.