My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2602 CLEVELAND AVE 2020-06-16
>
Address Records
>
CLEVELAND AVE
>
2602
>
2602 CLEVELAND AVE 2020-06-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/16/2020 12:09:50 PM
Creation date
6/16/2020 11:54:03 AM
Metadata
Fields
Template:
Address Document
Street Name
CLEVELAND AVE
Street Number
2602
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
"rovide one-hour fire-resistance rated construction on the underside of projections located in <br /> the side yard setback. No ventilation openings allowed. Provide detail showing compliance <br /> cross reference to plans. <br /> Provide Smoke Alarms per section R314 IRC. Show location of all smoke alarms on floor plans. <br /> Provide Carbon Monoxide (CO) alarms per section R315 IRC. Show location of all CO alarms <br /> on the floor plans. <br /> 20 Provide source specific ventilation per table M1507.4. Show size and location of all loc <br /> exhaust fans on the floor plans. <br /> ?Show location of water heater on plans. Indicate the location of the temperature and pressure <br /> relief line from the water heater to the exterior of the building. <br /> ?hower area floors shall be not less than 30 inches in minimum dimension and shall have at <br /> least 900 square inches of interior cross-sectional area. <br /> 23. Provide heating and cooling equipment sizing documentation per Section M1401.3 IRC Show <br /> how dwelling is heated. Show location of all heat sources on plans. <br /> Winding stairs shall not be less than 6 inches wide at any point within the clear width of the <br /> �i l,i„ stair per section R311.7.5.2.1 IRC Revise stairs to provide the minimum width of the tread at <br /> Gh� all locations. <br /> rovide stair section and details. Specify riser height, tread depth, size and quantity of stair <br /> stringers, stringer attachment, handrail height and size, fireblocking, headroom, landing and <br /> stair width, guardrail height and intermediate rail spacing. Provide 1/2 inch gypsum board <br /> separation within usable enclosed space under stairs (IRC R302.7) Show requirement on plans. <br /> -6. oilet, Bath and Shower spaces shall be spaced in accordance with Figure R307.1 and in <br /> accordance with the requirements of State plumbing code Section 402.5. Show all dimensions <br /> for bathrooms. <br /> 27 Provide separation between garage areas and the residence with a minimum 1/2" inch gypsum <br /> board on the garage side to the underside of the roof sheathing; garages beneath habitable <br /> rooms shall be separated from all habitable rooms above by not less than 5/8 inch Type"X" <br /> gypsum board or equivalent per (IRC A:Openings between the garage or carport and the residence shall be equipped with solid wood <br /> doors not less than 1 3/8"thick, or 20-minute fire-rated doors, equipped with a self-closing <br /> device per (IRC R302.5.1). <br /> X. Note and specify that the shower area walls shall be finished with a nonabsorbent surface, to a <br /> height of 6 feet above the floor (IRC R307.2). <br /> 30. Show compliance with section R806.2 IRC Provide attic ventilation calculations show the <br /> t625 required and the provided net free ventilation area (see #17 above). Detail and note on the <br /> plans the location of roof ventilation. <br /> how the required insulation for all walls floors and Ceiling. Show U-Values for all windows and <br /> doors. <br /> C9Show how you are meeting the requirements for"Energy Credits"per table 406.2 WA State <br /> Energy Code (WSEC). <br /> e <br /> Rage 3 of3 <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8810 • Fax(425) 257-8: <br />
The URL can be used to link to this page
Your browser does not support the video tag.