My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2828 COLBY AVE 2020-06-16
>
Address Records
>
COLBY AVE
>
2828
>
2828 COLBY AVE 2020-06-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/16/2020 1:56:22 PM
Creation date
6/16/2020 1:53:52 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2828
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
} <br /> • <br /> Skotdal '" T 425 252 5400 <br /> F 425 258 2473 2707 Colby Avenue Suite 1200 <br /> Post Office Box 5267 <br /> www.skotdal.com Everett Washington 98206 <br /> REAL ESTATE <br /> March 22, 2018 <br /> Tony Lee <br /> Building Official <br /> City of Everett Public Works �"' L:;,2" <br /> 3200 Cedar St .., <br /> Everett, WA 98201 MAR 2 6 2618 <br /> Re: Building Permit Revision Letter CITY OF EVpp r _ <br /> Plan Check No: B1801-002 Permit s � <br /> 'r!tl ' <br /> s <br /> Dear Mr. Lee, <br /> In reply to your building permit review letter, I offer the following: <br /> Construction: <br /> 1. The elevator machinery room is for housing the elevator electrical control only. <br /> The elevator-hoisting machine is located in the shaft. Per our discussion, the one- <br /> hour rating of the room is acceptable. The room name has been change on the <br /> drawing to reflect the foregoing. <br /> 2. Door 106, accessing the elevator electrical room, is rated 45 minutes to reflect <br /> compliance with comment 1 above. <br /> 3. Wall type ES-3, has been changed to ES-5 to meet clearance requirements for <br /> elevator control equipment. USG performance selector sheets showing 2 hour <br /> rating are attached for your reference. <br /> 4. Building section notes have been added to callout 5/8" Type 'X' GWB on the <br /> underside of the stair stringers. <br /> 5. The building sections through the east stairwell have been drawn showing the <br /> existing fire barrier materials that were shown on the remodel drawings approved <br /> by your department in 1984. The existing materials at the third floor and fourth <br /> floor ceilings consist of plaster ceiling materials on the existing joists (floor and <br /> roof).The third floor structure is comprised of bar joists and conc/form lock <br /> decking protected with spray-on fireproofing. Notes have been added to the <br /> building sections describing the installation of GWB and intumescent sealant <br /> necessary to meet the one hour requirement per section 707.5.1 <br /> 6. Drawings have been revised to show and note compliance with minimum one <br /> hour per section 1023.2 <br /> 7. Building sections have been revised to show and note fire barriers in stair <br /> enclosure continuous through the floor/ceiling assemblies per section 707.5 <br /> • 8. Architectural drawings have been revised to correct the inconsistency that was <br /> pointed out. <br /> !DOWNTOWN EVERETT I DISCOVER THE URBAN IN YOU <br />
The URL can be used to link to this page
Your browser does not support the video tag.