Asbestos Sample Summary 2of3
<br /> Lehigh Hanson Job Number: 16467
<br /> Cl PaeRi m 6300 Glenwood Avenue Print Date: November 2,2018
<br /> Everett,WA
<br /> 'roiect: South Everett CADMAN Plant
<br /> 6300 Glenwood Avenue
<br /> Everett,WA
<br /> Sample# Sample Date Sample Location AHERA Category Sample Description Asbestos Type/% Approximate Quant.
<br /> 20 10/20/2018 Exterior, Batch tower,2nd floor,west wall Miscellaneous Expansion Joint None Detected. N/A
<br /> 21 10/20/2018 Exterior, Batch tower, 2nd floor, west wall Miscellaneous Cement Asbestos Board Chrysotlle 25-30% 100 S.F.
<br /> 22 10/20/2018 Exterior, Batch tower,2nd floor,east Miscellaneous Carpet Mastic None Detected. N/A
<br /> stairway landing
<br /> 23 10/20/2018 Exterior,Batch tower,2nd floor,east wall Miscellaneous Expansion Joint None Detected(Both Layers) N/A
<br /> 24 10/20/2018 Batch tower,roof Miscellaneous Roofing penetration mastic None Detected. N/A
<br /> 25 10/20/2018 Batch tower,roof Miscellaneous Chrysotile 1-3% 20 S.F.
<br /> 26 10/20/2018 Batch tower,roof Miscellaneous rolled roofing None Detected. N/A
<br /> 27 10/20/2018 Batch tower, .t st floor,break area Surfacing Popcorn Ceiling l exture chrysotile i-'I in 600 S.F.
<br /> 28 10/20/2018 Batch tower, 1st floor,office Surfacing Popcorn Ceiling Texture rhrvsotile 10-15 See Sample#27
<br /> 29 10/20/2018 Batch tower,bathroom, north wall Miscellaneous Sheetrock(GWB) None Detected. N/A
<br /> 30 10/20/2018 Batch tower,southeast corner inside of TSI Pipe Insulation None Detected N/A
<br /> piping
<br /> 31 10/20/2018 „a it tower,break area,east wall Surfacing Layer 1 (Texture):Chrysotile 3-5% 700 S.F.
<br /> Layer 2(Drywall): None Detected.
<br /> 32 10/20/2018 Batch tower,break area,west wall Surfacing Texture on GWB None Detected(Both Layers) N/A
<br /> 33 10/20/2018 Batch tower,break area,west wall Surfacing Texture on GWB None Detected(Both Layers) N/A
<br /> 34 10/20/2018 Pre-stress building roof Miscellaneous rolled roofing None Detected N/A
<br /> 35 10/20/2018 Pre-stress building roof Miscellaneous -nf cenlent Layer 1 (Mastic):Chrysotile 7-10% 20 L.F.
<br /> Layer 2(Mastic):None Detected.
<br /> 36 10/20/2018 QC lab, interior wall Miscellaneous Sheetrock(GWB) None Detected (Both Layers) N/A
<br /> 37 10/20/2018 QC lab Surfacing Ceiling coating None Detected N/A
<br /> 38 10/20/2018 QC lab Surfacing Wall texture None Detected (Both Layers) N/A
<br /> 39 10/20/2018 Pre-stress building,exterior wall Surfacing Coatings None Detected. N/A
<br /> 40 10/20/2018 Pre-stress building,on ceiling TSI Insulation None Detected N/A
<br /> 41 10/20/2018 Batch mixing plant,boiler room Miscellaneous Chrysotile 40-45%, 2 Each !
<br /> 42 10/20/2018 Batch mixing plant, boiler room TSI Boiler Tank Insulation None Detected. N/A
<br /> 43 10/20/2018 Redi-Mix building,room#1 Surfacing Texture on GWB None Detected(Both Layers) N/A
<br /> 44 10/20/2018 Redi-Mix building,west hallway Surfacing Texture on GWB None Detected (Both Layers) N/A
<br /> 45 10/20/2018 Redi-Mix building,south wall Surfacing Texture on GWB None Detected(All Layers) N/A
<br /> 46 10/20/2018 Redi-Mix building,center area Miscellaneous Sheet Vinyl Flooring None Detected (Both Layers) N/A
<br /> Pacific Rim Environmental.Inc. 8510 Soufl'center Old core 40 T,-,',-....,,,'= WA QR1g9
<br /> This report shall not be reproduced,except in full.without written permission of Pacific Rim Environmental.Inc.
<br />
|