My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3623 HOYT AVE 1-3 2020-06-17
>
Address Records
>
HOYT AVE
>
3623
>
3623 HOYT AVE 1-3 2020-06-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2020 3:02:40 PM
Creation date
6/17/2020 2:58:30 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
3623
Unit
1-3
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
172
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Use menu item Settings>Printing&Titlk Title SIDHU Page: 2 <br /> to set these five lines of information Job# 7945A Dsgnr: CHRIS Date: 8 AUG 2017 <br /> for your program. Description.... <br /> This Wall in File:d:\sda archive\retainpro\7945.RPX <br /> RetainPro(c)1987-2015, Build 11.15.12.22 <br /> License:KW-06060593 Cantilevered Retaining Wall Code: IBC 2012,ACI 318-11,AC1 530-11 <br /> License To:STRUCTURAL DESIGN ASSOCIATES <br /> Footing Dimensions&Strengths 10FootingDesign Results <br /> Toe Width = 1.50 ft Toe Heel <br /> Heel Width = 1.25 Factored Pressure = 1,906 525 psf <br /> Total Footing Width = 2.75 Mu':Upward = 1,862 106 ft-# <br /> Footing Thickness = 10.00 in Mu':Downward = 218 174 ft-# <br /> Mu: Design = 1,644 68 ft-# <br /> Key Width = 0.00 in Actual 1-Way Shear = 17.90 2.26 psi <br /> Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi <br /> Key Distance from Toe = 0.00 ft Toe Reinforcing = #4 @ 11.11 in <br /> ' fc = 2,500 psi Fy = 40,000 psi Heel Reinforcing = #4 @ 18.00 in <br /> Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd <br /> Min.As% = 0.0018 <br /> Cover To 2.00Other Acceptable Sizes&Spacings <br /> @ p@ Btm.= 3.00 in Toe: #4@ 11.11 in,#5@ 17.22 in,#6@ 24.44 in,#7@ 33.33 in,#8@ 43.89 in,#9@ 5 <br /> Heel:Not req'd:Mu<phi*5*lambda*sgrt(fc)*Sm <br /> Key: No key defined <br /> Summary of Overturning & Resisting Forces & Momentsill <br /> OVERTURNING RESISTING <br /> Force Distance Moment Force Distance Moment <br /> Item lbs ft ft-# lbs ft ft-# <br /> Heel Active Pressure = 701.9 2.11 1,481.9 Soil Over Heel = 352.9 2.46 867.6 <br /> Surcharge over Heel = 181.4 3.17 574.3 Sloped Soil Over Heel = <br /> Surcharge Over Toe = Surcharge Over Heel = 52.5 2.46 129.1 <br /> Adjacent Footing Load = Adjacent Footing Load = <br /> Added Lateral Load = Axial Dead Load on Stem= 441.0 1.83 808.5 <br /> Load @ Stem Above Soil= *Axial Live Load on Stem = 595.0 1.83 1,090.8 <br /> = Soil Over Toe = 0.75 <br /> Surcharge Over Toe = <br /> Total 883.3 O.T.M. 2,056.2 Stem Weight(s) = 600.0 1.83 1,100.0 <br /> Earth @ Stem Transitions= 201.7 2.33 470.6 <br /> = = Footing Weighl = 343.8 1.38 472.7 <br /> Resisting/Overturning Ratio = 1.87 Key Weight = <br /> Vertical Loads used for Soil Pressure= 2,586.8 lbs Vert.Component = <br /> Total= 1,991.8 lbs R.M.= 3,848.4 <br /> *Axial live load NOT included in total displayed or used for overturning <br /> resistance,but is included for soil pressure calculation. <br /> Vertical component of active lateral soil pressure IS NOT considered in <br /> the calculation of Sliding Resistance. <br /> Vertical component of active lateral soil pressure IS NOT considered in <br /> the calculation of Overturning Resistance. <br /> TiltI <br /> Horizontal Deflection at Top of Wall due to settlement of soil <br /> (Deflection due to wall bending not considered) <br /> Soil Spring Reaction Modulus 250.0 pci <br /> Horizontal Defl @ Top of Wall(approximate only) 0.089 in <br /> The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, <br /> because the wall would then tend to rotate into the.retained,_soil., <br />
The URL can be used to link to this page
Your browser does not support the video tag.