My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3623 HOYT AVE 1-3 2020-06-17
>
Address Records
>
HOYT AVE
>
3623
>
3623 HOYT AVE 1-3 2020-06-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2020 3:02:40 PM
Creation date
6/17/2020 2:58:30 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
3623
Unit
1-3
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
172
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Use,menu item Settings>Printing&Title.. ,k Title • Page: 1 <br /> to set these five lines of information Job# • Dsgnr: Date: 8 AUG 2017 <br /> for your program. Description.... <br /> This Wall in File: C:\Users\Chris\Desktop\retain pro.RPX <br /> RetainPro(c)1987-2015, Build 11.15.12.22 <br /> License:KW-06060593 Cantilevered Retaining Wall Code: IBC 2012,AC1 318-11,AC1 530-11 <br /> License To:STRUCTURAL DESIGN ASSOCIATES <br /> Criteria I Soil Data <br /> Retained Height = 7.50 ft Allow Soil Bearing = 1,500.0 psf <br /> Wall height above soil = 0.50 ft Equivalent Fluid Pressure Method <br /> Active Heel Pressure = 35.0 psf/ft <br /> Slope Behind Wall = 0.00 = <br /> Height of Soil over Toe = 4.00 in Passive Pressure = 250.0 psf/ft <br /> Water height over heel = 0.0 ft Soil Density, Heel = 110.00 pcf <br /> Soil Density,Toe = 0.00 pcf <br /> FootingilSoil Friction = 0.000 <br /> • <br /> Soil height to ignore ,• ••`I <br /> for passive pressure = 0.00 in '' <br /> Surcharge Loads 11 Lateral Load Applied to Stem ` Adjacent Footing Load <br /> Surcharge Over Heel = 90.0 psf Lateral Load = 0.0#/ft Adjacent Footing Load = 0.0 lbs <br /> Used To Resist Sliding&Overturning .-.Height to Top = 0.00 ft Footing Width = 0.00 ft <br /> Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in <br /> Used for Sliding&Overturning Wall to Ftg CL Dist = 0.00 ft <br /> Load Type = Wind(W) <br /> Axial Load Applied to Stem i (Service Level) Footing Type Line Load <br /> Base Above/Below Soil = 0.0 ft <br /> Axial Dead Load = 441.0 lbs Wind on Exposed Stem = 0.0 psf at Back of Wall <br /> Axial Live Load = 595.0 lbs (Service Level) Poisson's Ratio = 0.300 <br /> Axial Load Eccentricity = 0.0 in <br /> Design Summary I Stem Construction I 2nd Bottom <br /> Stem OK Stem OK <br /> Wall Stability Ratios Design Height Above Ftg ft= 0.25 0.00 <br /> Overturning = 1.94 OK Wall Material Above"Ht" = Concrete Concrete <br /> Slab Resists All Sliding I Design Method = LRFD LRFD LRFD <br /> Thickness = 8.00 8.00 <br /> Total Bearing Load = 3,602 lbs Rebar Size = # 5 # 5 <br /> .resultant ecc. = 5.18 in Rebar Spacing = 15.00 15.00 <br /> Soil Pressure @ Toe = 1,484 psf OK Rebar Placed at _ = Edge Edge <br /> D <br /> Soil Pressure @ Heel = 317 psf OK Design Data <br /> 1,500 psffb/FB+fa/Fa = <br /> 0.724 0.794 <br /> Allowable = Total Force @ Section <br /> Soil Pressure Less Than Allowable <br /> ACI Factored @ Toe = 1,879 psf Service Level lbs= <br /> ACI Factored @ Heel = 402 psf Strength Level lbs= 1,803.9 1,918.6 <br /> Footing Shear @ Toe = 29.7 psi OK Moment....Actual <br /> Service Level ft-#= <br /> Footing Shear @ Heel = 8.2 psi OK Strength Level ft-#= 4,760.9 5,226.1 <br /> Allowable = 75.0 psi <br /> Sliding Calcs Moment Allowable ft-#= 6,578.7 6,578.7 <br /> Lateral Sliding Force = 1,453.9 lbs Shear Actual <br /> Service Level psi= <br /> Strength Level psi= 24.3 25.8 <br /> Shear Allowable psi= 75.0 75.0 <br /> Wall Weight psf= 100.0 100.0 <br /> Rebar Depth 'd' in= 6.19 6.19 <br /> Masonry Data <br /> fm psi= <br /> Fs psi= <br /> Solid Grouting = <br /> Vertical component of active lateral soil pressure IS Modular Ratio'n' = <br /> NOT considered in the calculation of soil bearing Short Term Factor = <br /> Load Factors Equiv. Solid Thick. = <br /> Building Code IBC 2012,ACI Masonry Block Type = Medium Weight <br /> Dead Load 1.200 Masonry Design Method = ASD <br /> Live Load 1.600 Concrete Data - <br /> fc psi= 2,500.0 2,500.0 <br /> Earth, H 1.600 <br /> Fy psi= 60,000.0 60,000.0 <br /> Wind,W 1.000 <br /> Seismic, E 1.000 <br /> /21 73 <br />
The URL can be used to link to this page
Your browser does not support the video tag.