My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3623 HOYT AVE 1-3 2020-06-17
>
Address Records
>
HOYT AVE
>
3623
>
3623 HOYT AVE 1-3 2020-06-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2020 3:02:40 PM
Creation date
6/17/2020 2:58:30 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
3623
Unit
1-3
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
172
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-, <br /> 2. The maximum rise of the entry and exterior stairs should be shown as 7 inches. Section <br /> 1011.5.21- 'C fiAtlL Ori 5nT 6 <br /> 3. The minimum run of all stairs should be shown as 11 inches. Section 1011.5.2 <br /> ;i-i rz DCT-Mi- o IL 1-S• <br /> 4. Handrails should bscifiedch side ofeach stairway. Section 1011.11 <br /> L ` '77 k <br /> 5. Handrail extensions should be shown for all stairs. Section 1014.6 <br /> ft itA , <br /> 6. The building entry is a corridor: <br /> a. Walls separating the corridor should be shown as minimum 30-minute rated <br /> construction. Section 1020.1 <br /> b. Doors opening into the corridor should be shown as minimum 20-minute ratings. <br /> S rk 4 Section 716.5,3 <br /> c. Wall and ceiling materials should be shown as minimum class C finish. Table <br /> 803.11 <br /> 7. All exterior guards should be shown to be a minimum of 42"high. Section 1015.3 <br /> s-isl am " o(- Gtr '' (IP - . ' ' Gi 5er t <br /> Energy(Residential Energy Code) and Air Quality <br /> 1. The location of the water heaters should be shown on the plans. The water heaters <br /> should be specified at a minimum EF of 0.91. Option 5c to Table 406.2 <br /> 1 The method of heating the dwellings should be noted on the plans. IBC Section 1204 <br /> 91-t-t--7, it4, <br /> 3. The plans should show a minimum of 75 percent of lamps in permanently installed <br /> lighting fixtures are high-efficacy lamps Section R404.1 <br /> ,'lam ' ) Cil'l'T ' 2 1 <br /> 4. An exhaust fan should be shown in the Master Bathroom of the lower unit. IMC Section <br /> 403.8 'J m -` - i <br /> 5. The sizing, location, control and sone requirements for the whole house exhaust fans <br /> should be shown on the plans. IMC Section 403.8.5 <br /> , ._(,,‘ tpc,x10 -/--t-tr-7 -27 ,k kt <br /> Structural <br /> L }6 c , <br /> 1. On Sheet 5/9, please designate and show the extents where detail 1/S4 and 5/S3 <br /> applies on all (4) sides of the plan. Please address and revise as required the <br /> discrepancy between the typical wall section on 1/S4 as it appears in conflict with what <br /> is shown on Sheet 8/9. <br /> 2. On Detail 154, please address and revise the reinforcement schedule for heights below <br /> 7'-0". <br /> 3. On Detail 1/S4, please verify that the retaining wall design accounts for the additional <br /> contributions due to earthquake surcharge pressures. <br /> 4. On Detail 2/S3.0, there does not appear to be clips or another means of transfer to <br /> resolve roof diaphragm shears into the shear walls below. Please revise details. <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425)257-8813 Page 245 <br />
The URL can be used to link to this page
Your browser does not support the video tag.