Structural Design Associates <br /> Engineering Structures to Last <br /> N G <br /> July 31, 2017 <br /> American Home Planners <br /> Attn: Lauren <br /> Subject: Building Official Comments, Plan Check# B1702-047 <br /> SDA Job # 7945 <br /> To whom this may concern: <br /> At the request of Lauren, with American Home Planners, this office reviewed the subject project to answer the <br /> building official comments. <br /> Following is our response to those comments: <br /> Structural <br /> 1. Foundation details 1/S-4.0, and 1/S-5.0 have been added. <br /> 2. The interior backfill height remains at 7'-O" on 3-sides. The rear wall has an 18-inch backfill height. <br /> 3. A surcharge pressure of 90 pounds was added to the heel side. <br /> 4. The H-1 clip has a lateral capacity of 415 lbs. The diaphragm shear is 54p1f. The roof sheathing is nailed <br /> into the block. The block transfers load to the truss, which transfers load to the H-1 clip. Detail 2/S3.0 is <br /> structurally adequate. <br /> 5. The attached calculations show that a 4x 12 PT HF#1 is adequate for load. <br /> 6. Detail 3/S-3.0 was not used. There are no holdowns on the upper level. <br /> 7. The attached calculation show that(3) 2x6 HF # 2 is adequate for buckeling. <br /> Please contact this office if you have any questions concerning this letter, or for any other. assistance. <br /> Sincerely, <br /> Chris Covington, P.E. <br /> w4.40:„ „7„, <br /> Vt <br /> y �. 4; • <br /> i <br /> a <br /> 34383 <br /> , FClsT oc9 <br /> SS`S f0NALG <br /> 017 <br /> .. _ _ . <br /> 60:), <br />