• <br /> July 3,2017 <br /> Single-Family Residence <br /> LezA Job No. 17-079 <br /> Page 16 <br /> pressure, a passive lateral soil pressure of 300 pef EFD (ultimate value) may be used. <br /> This passive pressure value is applicable only to walls with a level or ascending <br /> backsiope away from the walls for a horizontal distance of at least 1_5 times the wall <br /> height To resist against sliding, the friction force between footings and subgrade soils <br /> may be calculated based on a coefficient of friction of 0.55 (ultimate value). The above <br /> soil parameters are ultimate values based on a frilly drained condition of the walls, ancl <br /> proper factors of safety should be applied in the design of the building basement walls <br /> and retaining walls against sliding and overturning failures. <br /> A vertical drainage blanket, at least 12-inch-thick horizontally, consisting of clean, free- <br /> draining,pea gravel or washed gravel should be placed against the back of foundation and <br /> retaining walls to within 18 inches of the finish grade to prevent accumulation of <br /> groundwater behind and buildup of hydrostatic pressure against the walls. This drainage <br /> blanket fill should be compacted to a non-yielding state with a vibratory compactor, <br /> Structural fill should be used for the remaining wall backfill. The top 18 inches of the <br /> backfill may consist of compacted, clean, sandy soils. Heavy compaction equipment <br /> should not be allowed within the walls of a horizontal distance equal to that of the wall <br /> heights. A 4-inch perforated PVC footing drain pipe, as recommended in the <br /> DRAINAGE CONTROL section of this report, should be provided fo•r the foundation <br /> and retaining walls. The drain line should be hydraulically connected to the drainage <br /> blanket behind the walls and tightlined to the spreader pipe dispersion system. <br /> Retaining walls may be supported on footing foundations constructed on undisturbed <br /> advance outwash soil. Preparation of footing bearing soils, allowable soil bearing <br /> LIU & ASSOCIATES,INC. <br />
The URL can be used to link to this page
Your browser does not support the video tag.