Laserfiche WebLink
Review Reply 11/21/2018 <br /> Vladimir Pyatak Residence <br /> Plan Check No: C1808-007—Tony Lee — Bldg Official — Everett <br /> Non Structural: <br /> Construction: <br /> 1. Location of grade added to elevations/clouded on Al and A2 <br /> 2. Further details added to section A/A2 — not clouded <br /> 3. Fixed issue with misplaced beam lines over posts on A3 — clouded <br /> 4. Fnd vents moved away from Holdowns —clouded on A3 <br /> 5. A.B.s revised to 5/8" and clouded on detail 6/A3 <br /> 6. 1 hr fire resistive separation detail added on A4 with callouts clouded on A4 <br /> 7. Roof trusses indicated/clouded for Storage units on Roof plan A6 <br /> 8. Framing for 2nd floor overhanging the garage has been added/clouded on <br /> A4 showing a LVL rim board on the right side of the overhang, Til <br /> continuing out into the overhang with solid blocking at the door wall. <br /> 9. Cont. ridge vents/soffit vents calculated and noted on Al and on the <br /> roofplan A6. <br /> 10.Toilet area width dimensions added/clouded in all locations on A4 and A5. <br /> All are well over the min 2' 6". <br /> 11.Details 6&7/A3 have been corrected/clouded indicating backfill min ILO <br /> slab. <br /> 12.Exterior Raised Deck <br /> a. Code updated to R507.2.3 clouded on A6 <br /> b. The staggered 12" o.c. 1/2x3" galv. Lags were indicated in Detail <br /> 15/A6 (now clouded) as well as the Simpson DTT2Z connections (now <br /> clouded. In both plan and section view. Details added from Stuctural <br /> Engineer. <br /> c. ECC66 call out corrected/clouded in Detal 15/A6 <br /> Egress: <br /> 1. 6" min distance for fnd walls above grade have been indicated/clouded on <br /> elevations and section A, on Al and A2; max rise run indicated / clouded; <br /> and 3 risers indicated/clouded. <br />