Laserfiche WebLink
1111 34th Street <br /> Everett,WA 98201 <br /> Project Number:2017-0728 <br /> 5.0 FINDINGS (continued) <br /> Inventory of Suspect Lead-Containing Paint Coatings <br /> Sample Number Material Description Location Lead In mglkg Lead in% <br /> 2017-0728-Pb-1 Blue paint on wood Room 3-Interior,walls&trims 2100.0 0.2100 <br /> 2017-0728-Pb-2 White paint on wood Interior,walls 570.0 0.0570 <br /> 2017-0725-Pb-3 Beige paint on wood Interior,walls&trims 7900.0 0.7900 <br /> 2017-0728-Pb-4 Green paint on wood Exterior,siding 7700.0 0.7700 <br /> 2017-0728-Pb-5 Beige paint on wood Exterior,window/door components and trims 2700.0 0.2700 <br /> Lead content of material analyzed is below the Lower Detection Limit, <br /> Samples in bold contain lead in excess of detectable levels <br /> Highlighted samples were found to be lead-based paint <br /> 6.0 CONCLUSIONS AND RECOMMENDATIONS <br /> There were no asbestos-containing building materials identified during the Good Faith Asbestos <br /> Inspection at 1111 34th Street, Everett,WA 98201. <br /> Contractors should be aware that concealed suspect asbestos-containing building materials may be <br /> uncovered during the course of demolition or renovation work. Contractors should have contingency <br /> plans that include stopping work, evacuation of the immediate area and sampling by a certified AHERA <br /> Building Inspector whenever these materials are found. Concealed suspect materials may include, but <br /> are not limited to: non-fiberglass pipe or roof drain insulation; spray-applied coatings; cement board; <br /> asphalt or paper vapor barriers; floorings and adhesives. <br /> If discovered, all asbestos-containing materials that will be disturbed as a natural part of renovation <br /> /demolition are required to be removed & disposed in accordance with Washington State regulations. <br /> Washington State Department of Labor and Industries and PSCAA requires that the abatement be <br /> performed using Certified Asbestos Workers under the direct on site supervision by a Certified Asbestos <br /> Supervisor. <br /> NVL Labs, Inc. is making the following recommendations regarding asbestos: <br /> 1. A copy of this inspection report should be maintained at the project site during the duration of <br /> renovation/demolition. <br /> 2. A copy of this inspection report should be provided to the General Contractor and any Sub <br /> Contractors working on the renovation/demolition project. <br /> 3. The inspection report is not intended to serve as a design/bidding document, or scope of work <br /> prior to renovation/demolition. <br /> NVL Laboratories,Inc. <br /> 4708 Aurora Ave N <br /> Seattle,WA 98103 <br /> Phone(206)547-01.00•Fax(206)634-1936 9/3 5 <br />