6. Storm water shall be managed in accordance with the City's 2010 Storm water Management Manual". <br /> 7. Surface water: The project is in the combined sewer area and redevelops more than 2,000 S.F.of impervious <br /> area;therefore compliance with interim policy 2-11 is required. Storm water shall be controlled according to <br /> the requirements of 2010 storm water manual and minimum requirements 1-5 apply. Provide on-site storm <br /> water management(min requirement#5)to extent feasible. Do not connect roof drain directly to the side <br /> sewer or lateral.Provide information on site plan showing existing and proposed drainage features and where <br /> surface water will discharge from the site. <br /> 8. Approval of construction plans will require demonstration that all pertinent standards and regulations are met. <br /> 9. A fire hydrant is required within 200 driving feet but not closer than 50 feet of every structure. <br /> 10. A fire hydrant is required within 350 driving feet of every structure. The hydrant(s) must meet City <br /> specifications. <br /> 11. City streets are to be kept clear of dirt and debris at all times during construction. Dust suppression and street <br /> cleaning must occur as directed by the Public Works Inspector. <br /> 12. Lack of comment on the plans submitted with the application does not constitute approval of these plans. <br /> 13. As-builts of storm sewer,sanitary sewer, and water systems will be required to be submitted per City Design <br /> and Construction Standards and Specifications for Development. <br /> 14. Walkways must be provided from the building entrance to the public sidewalk. <br /> 15. The construction plans must be designed from a site survey performed by a licensed State of Washington land <br /> surveyor. <br /> Fire Department,Assistant Fire Marshal—Jim Venture—425.257.8124 <br /> 1. Access to the structure on this lot will be excessive.This may be mitigated by the installation of a residential <br /> sprinkler system in compliance with the requirements of NFPA Standard I3D.A minimum 1-inch domestic <br /> water service meter is required. <br /> Plans for such a system shall be submitted to the Engineering&Public Services Department and the Fire <br /> Department for review and approval prior to commencement of construction. <br /> A final"in the bucket"and alarm bell test,witnessed by a fire inspector,will be performed prior to acceptance <br /> of the system. Call(425)257-8124 or(425)257-8120 for more information.For alley side home unit 3. <br /> 2. Fire Hydrants-Locations as planned are acceptable. <br /> 3. Fire flow for this project is 1,000 gpm. <br /> 4. 13D Single-Family Home Sprinkler System—Valves shall be in heated rooms or garages.Minimum <br /> temperature shall be maintained at 40°F (NFPA 13D&13R, 2013 edition,section 9.1). <br /> Planning Department—Kelsey Heyd--425.257.8731 <br /> 1. Covenant and Easement.A covenant acceptable to the City Attorney's office shall be recorded on the title of <br /> the subject property and property to the north(3305 Oakes Avenue,00439079400100)to maintain access for <br /> Sage 3 of 4� <br /> REVI I16-015 <br />