Laserfiche WebLink
i f ENGINEERING <br /> a# PUBLIC SERVICES DEPARTMENT <br /> January 26, 2018 <br /> Land Liaison • - <br /> PO Box 266 , ' 4 4 ' "' s.. ' <br /> Snohomish WA 98291 <br /> �. e ::' RA <br /> RE: Owner: Reykdal <br /> Job Address: 7109 Rainier Drive <br /> Plan Check Number: C1712-004, C1712-005, C1712-006 & C1712-007 <br /> Ms. Albert, <br /> In response to your application for a construction permit, your plans have been examined and you <br /> are advised that the issuance of a permit is being withheld for the reasons listed below. These <br /> comments address building issues only. Additional revisions or additions may be required by other <br /> departments such as Utilities, Planning or Fire. All references refer to the 2015 International <br /> Building Code (IBC), 2015 International Residential Code (IRC), as amended by the State of <br /> Washington and/or Washington State Energy Code (WSEC) 2015 Edition, as adopted by the City of <br /> Everett, unless stated otherwise. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Division with two new complete sets of drawings reflecting the <br /> corrections requested. <br /> Construction documents shall be of sufficient clarity to indicate the location, nature and extent of <br /> the work proposed and show in detail that it will conform to the provisions of the building code <br /> and relevant laws, ordinances, rules and regulations. <br /> ARCHITECTURAL&ENERGY CODE REVIEW <br /> 1. The installation of the water heater and the furnace in the garage would eliminate one of <br /> the required parking spaces in the garage. Provide minimum two spaces not less than 8.5' <br /> x 18.5' in the garage. see Gtut.t.iCPE To Fs.R PI,Att ®N 544T..S.• 3 440 <br /> 2. Detail"F"on sheet 3 shows rigid insulation between the garage and the conditioned space <br /> going down approximately 4 inches and then turning 90'degrees to go under the slab. Rigid <br /> insulationjs required to go down for a minimum depth of 24 inches when installed at the <br /> perimeter•of a slab-on-grade located in a conditioned space. The transition from section H <br /> to section F does not meet the intent of the energy code. 4.1.E GNawvEs T® OTLS 0449 <br /> Os 610 3 4. l&LI.OU1 Amer) 'CO pow• i13L4N ,01v 5 4T5 3 4 Co <br /> 3. Sheet 3 references an"alternate entry for west most dwellings - shown Sht. 7". The details <br /> on both sheets are the same. Please clarify (and correct sheet number). see DeTALLs <br /> GALLCp OUT ON Put•PLANS ok 56.4Tb• 3,6 , 4 7 <br /> 4. Provide detail of the connection of the concrete porch at the entry to the foundation, <br /> capable of resisting differential settling. SEE OT4 a) ADC) DO .‘wi T 8 \V/GAt.4ot, S <br /> „ <br /> AtPt�ED Ta. k)14.1:140) ON =>l4Th. 31#114.7catfge <br /> CITY OF EVERETT• 3200 Cedar Street • Everett, WA 98201 • (425)257-8810 • Fax(425) 2 <br />