My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7109 RAINIER DR E F 2020-07-15
>
Address Records
>
RAINIER DR
>
7109
>
7109 RAINIER DR E F 2020-07-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2020 8:36:43 AM
Creation date
7/15/2020 8:35:24 AM
Metadata
Fields
Template:
Address Document
Street Name
RAINIER DR
Street Number
7109
Unit
E F
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. <br /> 5. Provide section drawing at cantilevered exterior deck over living space specific to this <br /> structure. Show all components and flashing. SEE t)OtE 041641l4AL.L:t f'ROVIP P <br /> 1 N P[L ® 514T.4 E 5e>` h1E.o DTI.. tooPeD sHee t' 8. <br /> 6. Specify Handrail requirements per section R311.7.8 IR how requirements on the plans, <br /> do not simply reference the code section. see t7TL. APPEP Of) st T" <br /> 7. Provide Smoke Alarms per section R314 IRC on the lower floor and middle floor. Show on <br /> plans. SEE ALATzt41 APP To FLA FLAPS 00 S t$ 23, 4& <br /> 8. Provide Carbon Monoxide Alarms per section R315 IRC on the lower floor and middle floor. <br /> Show on plans, SEE C.aMMBO ALARM APPWP let I=LR PLAOS 614 £HTS 213144 <br /> STRUCTURAL REVIEW <br /> 1. Please list the design criteria for the proposed structure per IBC 2015 Sec 1603 include <br /> items such as, but not limited to design loading, base shears (seismic and wind, which ever <br /> governs the design), bearing pressures, and wind criteria. set 1TEMs ApPep 1 <br /> 51T, <br /> 2. Please identify which elements have been designed per the IRC 2015, please include any <br /> supporting documentation to how the beams,joists, bearing walls, columns, and etc. were <br /> determined using the design loads, span tables, and deflections indicated in the design <br /> criteria. If supporting documentation cannot be provided,from the provisions of the IRC <br /> 2015, please identify these elements and provide design calculations stamped by a <br /> Washington State professional engineer. Calculations and designs are based using <br /> references to current design standards listed in the IBC 2015. AU. ELEME)31t ARE f R <br /> 2015 IBC I ASGe 7-0 20111 E SproV5 20K SEE ORt&MAL. ST e.T. CAL.C$. 7-32-17 <br /> 3. It appears that a steel cantilever column lateral system is being provided at the first floor <br /> level of the structure. Per ASCE 7-10, Sec 12.14 and Table 12.14-1, cantilever column <br /> systems are not covered by this section. The lateral system being proposed is found under <br /> Table 12.2-1 of ASCE 7-10 however, a structural analysis would need to be provided using <br /> the provisions utilizing Table 12.2-1 and currently is not a permitted lateral force resisting <br /> system i Seismic Category D. Please provide a revised lateral system and analysis. <br /> se.a. NEIN - stiaT FAME a` 444.4 S. PROM STRu41. ENGR.• roan ZAw t ocK <br /> 4. It appearrs ha "` proposed cartitever8cblumn system utilizes the slab-on-grade as a <br /> means of restraint for the cantilever column. Please provide additional details and a <br /> narrative describing how full restraint is achieved by the slab-on-grade. <br /> seta 1YEM 43 <br /> 5. It appears that detail T, cut at the foundatio level near the steel columns, was not <br /> provided, Please provi this detail. 1744.0 SHO"vN sHT. 1 1S Pow VitilzEb. <br /> SECS <br /> WE / PVL (cs.) ON Nev.; per..1 <br /> 6. Please specify the type of hot rolled steel to be used for the lateral system in the general <br /> notes. Please reference the applicable ASTM specifications for steel components, such as <br /> shapes and plates. SEE tie AJ,ED art SNt. e <br /> 7. Please specify the weld material in the general notes. Please refer to AISC 360-10 Chapter <br /> for the weld material specifications. SEe NOTE Atawet) 450 SHT. fa <br /> Page 2 of • <br /> CITY OF EVERETT• 3200 Cedar Street• Everett,WA 98201 • (425) 257-8810 • Fax(425)25 - <br />
The URL can be used to link to this page
Your browser does not support the video tag.