My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7109 RAINIER DR E F 2020-07-15
>
Address Records
>
RAINIER DR
>
7109
>
7109 RAINIER DR E F 2020-07-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2020 8:36:43 AM
Creation date
7/15/2020 8:35:24 AM
Metadata
Fields
Template:
Address Document
Street Name
RAINIER DR
Street Number
7109
Unit
E F
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IM <br /> 8. Please provide a schedule of Special Inspections that include, but is not limited to wood <br /> shear walls and their nailing for spacing closer than 4"o.c., use of post-installed anchors <br /> into concrete, welding,and steel fabrication. See IBC Chapter 17. .5Ee. HG Li <br /> APPMP P -to ,Nasi S <br /> 9. The current shear wall schedule with the values provided do not appear to be consistent <br /> with the capacities listed in Table 4.3A of SDPWS 2015 even when using reduction factors. <br /> Please provide additional information as to how these shear values were obtained. For <br /> instance, a 7/16"wood-structural panel w/ 8d nails at 6"oc edge nailing yields a design <br /> capacity of 240 plf for seismic and 335 plf for wind using ASD. Please clarify as the value <br /> 0 97if on thedesign calculations dos not Correspond to these v lues. <br /> NTf'AGHt� G4641( ®N $tie Nutt• L P 'l't�S .5,NO +iNfa Go Met,IAhlcA <br /> 10. Please provide foundation checks for the steel cantilever columns. Please include checks <br /> for global overturning, bearing, and stability. Also, please check the foundation for flexure <br /> and shear using the most current concrete design standard of ACI 318-14. <br /> E A V• ITER*3 • <br /> 11.It appears lateral design calculations were provided for 1/z of the structure. Please revise <br /> the analysis to include the entire structure in both directions. For example, the walls <br /> between units would be experiencing twice the load, but the calculations and design does <br /> not appear to reflect this. Please clarify and revise as required. Vo 41,6,4‘siat3 D <br /> 461147 I .peve Mai2i;r Lu.`f• $Ci: PIN J At3D .PTt. . GAL-.644'i CCU PLAt4.4 <br /> 12. Please provide reference as well as the adjusted stress values for the wood framed <br /> members being designed in the permit calculations. Please identify which NDS 2015 <br /> factors were used in the design of these members. tty, FtfrVt5tog hleaPep <br /> $eE earAG 4 41$1044,5 4S VAi.U6s 6P WttoP '5144YtV!14(? G ruoAt�4El. As <br /> oliivi a3AU.Y ..$41 04`4 I'W . <br /> If you have any questions on the architectural &energy code review, please email or call me at <br /> (425) 257-8976. <br /> If you have any questions on the Structural review, please email James Brander at <br /> jbronder( everettwa.gov or Call James at(425) 257-7287. <br /> Upon submittal of the drawings, your application will be given priority and plan reviews will <br /> recommence. All required submittals shall be sufficient detail and contain sufficient information to <br /> ensure that the proposed structure will be constructed in compliance with all adopted codes. <br /> Please prepare a response letter showing where each item in this correction <br /> letter is addressed on the plan set. <br /> Sincerely, <br /> )eff Heilman <br /> Development Technician <br /> City of Everett Public Works Department <br /> 3200 Cedar St, Everett, WA 98201 <br /> Office: 425-257-8810 ( Direct: 425-257-8976 <br /> Email: JHeiimanCaeverettwa.gov �----- <br /> Page 3 of. " <br /> fr- <br /> CITY OF EVERETT • 3200 Cedar Street• Everett, WA 98201 • (425) 257-8810 • Fax(425)257-8: <br />
The URL can be used to link to this page
Your browser does not support the video tag.