Laserfiche WebLink
R�ov�a,e� sHE�F To a,��ow GENERAL NOTES <br /> 12" WATER TO DRAIN THRU. BLDR FOR WINDOWS WI1N OPERABLE OPENINGS MORE � <br /> 70 DETER�IINE METHOD • � o <br /> THAN 72 ABOVE THE FINISHED GRADE OR <br /> 2x6 SILL SURFACE BELOW, THE LOWEST PART OF THE W I <br /> 2x12 BLK�G 1x2 BLK'G BTNM JSTS � �- M <br /> CLEAR OPENING SHALL BE 24 MINI�fUM ABOVE � � � <br /> 2x4 �2HF TRIM CAP THE FLOOR. EXCEPTIONS: FULLY OPEN WINDOWS � <br /> ?'� ; � WHERE A 4" 5PHERE MAY NOT PASS THROUGH d '1 <br /> 2x6 BLK'G 2x8 TRIM BAND OR WNERE FALL PREVENTION DEVICES ARE U � <br /> 24�`�� 2x6 #2HF FRAME PROVIDED PER ASTM F 2090 OR R612.3. � Z � <br /> 16'-10" 7'-2" � PROVIDE SAFETY GLASS PER IRC R308. �� � <br /> ;:, 2x BLK'G ON UNDERSIDE <br /> OF 2x6 FRAME. <br /> 12'-10° 4'-0" j SKYLIGHTS TO BE DOUBLE PANEL, SHATTER �r � <br /> � RESISTANT APPROVED RIGID PLASTiC, LAMINATED o <br /> 4x6 �2HF TRIM/SUPPORT Z cv <br /> . 2'-1" 7'-8" SAFETY GLASS, FULLY TEMPERED GLASS, ,� <br /> 2x4 �2HF CORBELS HEAT-STRENGTHENED GLASS, OR WIRED GLASS. � � � <br /> PROVIDE 4" MINI�fUM CURB (OR SELF FLASHING �� J � <br /> A55EMBLY WITH 3:12 MINIMUM PITCH OR PER <br /> �-��� ,,.�r( �� i-1 , 6x6 SHADOW BOX MANUFACTURER INSTRUCTiONS). � m <br /> 46 12 ABV BR G PLUMB. NON-SIRUCT. TRIM � <br /> 46 36 XO pg WALL�2x6 STUDS � HOSE BIBBS TO BE BACKFLOW PREVEN110N AND � °� � <br /> �`S�""�' .__ .�. 2 2x6 2HF .�. �..��!�;W��.�Q� � 16 O.C. FREEZE RESIS7ANT TYF'E. W w <br /> ri/i�i�iii%i��i!i�i' i�! /'ii ii��ii�i�ii i,�/i �ii� ;�i.r�ii i�/�i'i��iiii!iii�ii��iii��::�ii ii/;ri��//� + � � W <br /> �i i ri ii ri ri�/ii iri� . <br /> ,, `� � NOTE: ALL WOOD TO BE PAINTED ALL HOLDOWNS. FRA�IING ANCHORS & SHEARWA L � � <br /> ' j ' 0O ' ' � A N D/O R W E A T HE R RESISTA NT H A I L I N G M U S T B E IN S P E C T E D B E F O R E C O V E R I N G. S �.; <br /> � �� .� . <br /> o ii ! (V i �i o � (� <br /> � � �� D.W. � � UP 16 RISERS �� i M � <br /> S T A I R W A Y S P E R I R C R 3 1 1.7 o I J.1 <br /> � ' ~ % '� �� � � �B P L A N TE R S H E L F D TL O 36" MIN. STAIRWAY WID1H. LANDINGS SHALL � W O <br /> ', c Z ;i <br /> . ,� ; i „ , „ H A V E A 3 6 M I N I M U M D I M E N 5 1 0 N I N 1}i E � <br /> °B �' N K I TC H E N N � % n % SCALE: � = 1 -0 J o <br /> � � � 2� ' " �� I I B� � R Q U I R E D W I-I E R E T H E R E I 5 AD O O RS A T T H E c ¢ <br /> %' 100 CFM HOOD � '' TUDS � FIASHING CAP aVER �� � � <br /> a' � i � ' V E N T T O E X T. I I � � Q, TOP OF AN INTEF�IOR FLIGH7 OF STAIRS, � � <br /> „ � 22" 2' " , � � INCLUDING STAIR5 IN AN ENCLOSED GARAGE, 3 Q .- <br /> I % ; ' t o 4x10 7RIM BAND UNDER PROVIDED THE DOOR DOES NOT SWING OVER 3 U �' <br /> � � � OPT. ISLAND W/16 � � �; � � THE STAIRS. RISERS TO BE 73'� MAXIMUM <br /> �� r------ � � ; � � '� � MSTR SUITE WINDOWS ° � � <br /> I '; � RAISED BAR � � ' ' cn , �fl HEIGHT AND TREADS TO BE 10 �11NI�1UM <br /> ___ pc o � � w j INSTALL 2x6 BLK'G 1" BEVEL CUT DEPTN, B01H WITH A MAXI�IUM VARIATION OF <br /> I % �---------� � , �, BEHIND TRIM �. TREADS WIT�I SOLID RISERS TO HAVE � � o <br /> '%� l ) ' � � � / I 2x6 CORBELS MINIMUM TO tY4 MAX. NOSING OR 11 MINIMUM o 0 <br /> _ � �------� DEPTH. 4' SPNERE MAY NOT PASS THROUGH � c•r <br /> � o ;' (1)STUD �r , �1)STUD FIRESTOP OPEN RISERS ON STAIRWAYS RISING MORE o � <br /> N `" � �% 6'-0" 5'-0" 5'-10" 3'-6" 3'-8" 6 MSTR SUITE 2x8 #2HF RFTRS C� TNAN 30". HANDRAIL REQUIRED 1� 4 OR MORE N N <br /> 24"�.C. CU7 TAIL TO 3Y" RISERS TO BE INSTALLED BETWEEN 34"-38` � � � <br /> I ' 17'-6" I 6'-6" O m N � R-21 INSUL 2x6 2HF LEDGER ABOVE N051NG AND HAVE A 1Y"-2"� GRIP � } a <br /> �� 3�� ��� �o Q � '� 12 # F I.I G h I T.0 R E T U R N�E N DI S T OL W A LN O R{N E Y V E LE � m � <br /> �( ,� 1 4 x 11 g 1.9E SA � d- � r� BEAM PER PLAN M11 ROOFING INS7ALL 2x10 BLOCKING BE7WEEN S1UDS TO � w <br /> t ;� MICROLAM LVL � � o » 5UWPOR7 HANDRAIL BRACKETS. FIREBLOCK � <br /> � R-38 INSUL 1 AlR SPACE , „ <br /> .�I ; PKT UP FLUSH � � 3� BETWEEN STUDS AT STRINGER. 6-8 MINIMUM <br /> %% �, � 2x SCREENED VENT BLK VERTICAL HEAD CLEARANCE. PROTECT <br /> �n� � N � v � i Q JSTS PER PLAN ENCLO5E0 ACCESSIBLE UNDER STAIR WALLS <br /> %� ' , , , ,/j� � AND CEIUNG WITIi �Z" GWB. U <br /> ; DINING RM ,, <br /> I %� ' 2+ PWDR %' I � BATHROOM NOTES � <br /> o � � � % > <br /> F `� '% a � �� ��" p x C A / � �REBLOCK TUBS AND SHOWERS PER R302.11. <br /> 30"x30" MINIMUM CLEAR SPACE IN SHOWER. 22" <br /> o M � ;, . =,d. 3 � �50 � � � 0 2 4 LE T - MINI�IUM WIDTH SHOWER DOOR TO OPEN OUTWARD • <br /> 00 ( % �8 3 SIDED GAS � � O � �,'1 `� o�o IF HINGED. 30" WIDE X 24" DEEP CLEAR SPACE �'-' <br /> K, , ;r, m 0 � r, FIRESTOP <br /> i � D.V. FlREPLACE � % � ,� 'n REQUIf�ED OUTSIDE SNOWER DOOR. ENCLOSURES <br /> `D ;' , I L�`CA 2.dy TO BE SAFETY GLASS. NONABSORBENT SURFACE � �' <br /> I , O � ��IQBL UP 6 WITH SHOWER. USE CEMENT BOARD OR ¢ � <br /> ,� ��, %� � �,/ %,%� ,,,,,,� STUDS y��'�� ''�`'��t L STORE DR CEMENT FIBER BOARD FOR TILE BACKING. VAPaR C� � <br /> � ( � ,;� 2 2x6 2HF • BEYOND R-21 INSUL a BARRIER NOT PER�IITTED BEHIND W.P. GWB A7 � W <br /> # � � � � EXT. WALL. 2.5 GPM SHOWER FLOW RESTRICTOR. o <br /> , i o� a, o, TUB OR SHbWER CONTROL VALVES TO BE � � <br /> �� % �� 2 3�2� 12 w�� ' <br /> I <br /> PRESSURE BALANCE OR THERMOSTATIC MIXING <br /> =v' I ,% 11�" TJI 360 (� 16"O.C. ;,� H ABV ��) "�� M w <br /> cn� , ��� TYPE. 1.6 GAL PER FLUSH MAXIMUM TOILETS. 15 � N <br /> ' TYPICAL THROUGHOUT � �� �. Y � � FIRESTOP � <br /> � ,, CLEAR SPACE REQUIRED. EACH SIDE FROM t OF �e <br /> �� 12i ;, � � �� 18" � O� I RX�� LI VI N G R M � TOILET � 21" CLEAR SPACE REQUIRED IN FRONT. � <br /> �� � � I p W Q � O��°- OPT. HINGED LID_/�� INSTALL 2x10 BLOCKING FOR TOWEL BARS UP 48" (Z✓ <br /> � % LI VI N G R M � � N �U I � FOR STORAGE U/ � ABOVE FLOOR OR BELOW SILL HEIGHT IF AT <br /> i / �„ i,3.` � Q ... � 2 2x4 #2HF DGER WINDOW. INSTALL BLOCKING FOR T.P. HOLDEkS. � <br /> � ; � w� � BUILT-IN 1MNDOW 2x8 #2HF �s � GUARDS PER IRC R312 <br /> � � %�� J �W SEAT BEYOND ^ � <br /> � ,m� = c� I o 24 O.C. 1 :12 PITCH O W1-IERE > 30" ABOVE FLOOR OR GRADE LEVEL <br /> � � %; �l� � �j� :�. R BELOW. 36" MINIMUM HEIGHT (AT OPEN SIDE OF � <br /> >� � (2)13'4" x 11�" 1.9E MICROLLAM ';� o II �� � �i STAIRWAY 34" MINIMUM HEIGHT MEASURED <br /> F m�� � LVL PKT UP FLUSH ;,o N � V II� �� `D _� 2x SCREENED FRO�I NOSING). SPACE PICKETS SO THAT 4" <br /> Q X I VENT BLOCK S P H E R E M A Y N O T P A S S T N R U (4�� S P H E R E A T � p � <br /> � �I M r ,� r ,� ' ¢z OPEN SIDE OF STAIR). TOP OF RAIL TO RESIST <br /> '� o o N 3a 6� STORE DR = � 3� 2 0 0 L B. L O A D I N A N Y D I R E C 1 1 0 N. P I C K E T S O R <br /> �I� � ,-: SAFETY GLASS N x � �m J S T S P E R P L A N <br /> I " � d 3� 1� ABOVE � ¢ ° � CO I 2x4 2HF CL'G INFILL TO RESIST 50 LBS. APPLIED TO 1 SQ. <br /> �+ � x � � � I i R-301N5UL # <br /> I � �, � N I � � � � ° co „ J S T S � 2 4'� O.C. �• �EA. GLAZING IN NANDRAILS AND GUARDS <br /> � `� ^ ^"' "' II� � BEAM PER PLAN 12 TO BE DESIGNED WITH A SAFETY FAC?OR OF 4. Q <br /> = L ; � � � � <br /> � � F�RE PRo�cT PER No�s GAS FIREPLACES IRC G2434/G2435 �-��3�j� �o <br /> a' � ; 4x8 #2DF � (4)STUDS 6x10 2DF �44)STUDS � O VENTED GAS FIREPLACES/FlREPLACE HEATERS - �� .� w c.�� <br /> i/ r i; �i .... r--- --i �''����:�. N <br /> G A R A G E SHALL BE TESTED PER ANSI Z21.50/Z21,88, �� <br /> ` � ���3� XO INSUL & SOFFIT ,i BENCH ' �' ,l N 4x6 0 . 2'-p" 2'-p" INSTALLED PER MFGR'S. INSTRUCTIONS (TO BE � o N� <br /> � -L ---�—--`� - % r''------ - .� � COL � ON SITE FOR INSPECTOR). EXCEPT FOR GAS (,� �' ''� <br /> N 6� 12 ABV INE OF CANT � i � N ' , n " c=� <br /> �..� �, , , , ,,/ � 4-11Y2' 4-0 FIREPLACES TESTED PER ANSI Z21.60, THE � N �� <br /> APPLIANCE SHALL U1ILIZE A DIRECT IGNITION <br /> t%° x 11�" 1.9E 13" 7'_¢„ �,� � �2 xfi _ 1�" x 11�" 1.9E � DEVICE, AN IGNITOR, OR A PILOT FLAME TO Q � �w <br /> MICROLLAM LVL 6 46 SH 26 46 SH MICROLLAM LVL LINE OF <br /> PKT UP FLUSH ��~� 7�i 26 12 AB V 26 12 AB r'""� PKT UP FLUSH PORCH BLW C P A R TI A L S E C TI O N TH R U LI VI N G R 0 0 M sH�� EE E UI pE �E MA�IN BURNER, & N o � � <br /> Q P D W I T H F L A M E <br /> LINE OF 6 RAGE BE OW �'j{�-.� „ , „ SAFEGUARD DEVICE THAT AUTOMATICALLY `l' o� <br /> j'7 C S C A L E: 3� = 1 -0 SHUTS OFF THE FUEL SUPPLY WI-IEN THE w o z <br /> 1'-9"G � 2' 1Y2» 2'-6" 3" - MEANS OF IGNITION BECOhAES INOPERATIVE. � � a w <br /> s N O N C O M B U 5 1 1 6 L E Fl R E B L O C K R E Q U I R E D A T � �F z <br /> � �� _._� � S E C 0 N D F L 0 0 R P L A N SCALE: Y" = 1 -0" VENT DUCT OPENING AT FLOOR AND CEIULNG � �-' <br /> 17'-0" ' S 2'-0" ,,y - LEVELS. INSTALL Y GWB FIREBLOCK BETWEEN � <br /> 813 SQ. FT. LINNG CHASE AND ATTIC. L�. �� <br /> r�Et��ns�octf��res,r�s o 0 <br /> 9'-6" 9'-6" a3�i-2�rl E►srrzLc�r s.w. <br /> � <br /> Eo,,�°N°s.WA�B°2� �LECTRICAL LEGEND <br /> 19'-0. 5,_�� �azs)���-?7'�3 <br /> 24'-0" ! ST'RUCTUIZ�L REViEW SMOKE ALARM PER R314 & LISTED PER UL 217. <br /> � �rtiis nxnv:�rP,��ins 3�:r�v�Ev»�vco EOR sA INSTALL PER HOUSEHOLD WARNING PROVISIONS OF <br /> �rRi!c�ruani.xeQuisir�,i�u�rso,��.vYFk�rifF NFPA 72 & PER MFGR. SPECS. 110V NOUSEH01� <br /> CURRENT WI7H BATfERY BACKUP. INTERCONNECT � <br /> n►iACFtr_n Lcrr�r�A�:Urort ca�.cu[.n�i��ovs. EACH BEOROOM AND LEVEL <br /> �Y._ �-�"�` _.___. �_.�.__.�._ 50� 50 CFM (�11N.) EXHAUST FAN - VENT TO EXTERIOR. <br /> �or��r: (� ��41 �fi-rc t� t� �.�3�9 �F <br /> voin tr r;o i��vr:�r S�cNc� ���� ��' � - <br /> - - �-----�- - - <br /> f���1��1��1�� ��� ����1"f. <br />