Laserfiche WebLink
� <br /> GENERAL NOTES <br /> FOR WINDOWS WITH OPERABLE OPENINGS MORE M <br /> THAN 72" ABOVE THE FINISHED GRADE OR � o <br /> SURFACE BELOW, TNE LOWEST PART OF THE W I <br /> CLEAR OPENING SHALL BE 24" MINIMUM ABOVE � I— ,� <br /> THE FLOOR. EXCEPTIONS: FULLY OPEN WINDOWS Z � <br /> NMERE A 4" SPHERE MAY NOT PASS THROUGH � W .-� <br /> OR WHERE FALL PREVEN110N DEVICES ARE U N <br /> PROVIDED PER ASTM F 2090 OR R612,3. � z � <br /> 24'-0" <br /> PROVIDE SAFETY GLASS PER IRC R308. �0 J <br /> a. <br /> ���-4� 5�-6� ��-2� SKYLIGH75 TO BE DOUBLE PANEL, SHATTER � � <br /> RESISTANT APPROVED RIGID PLASIIC, LA�IINAlED <br /> ��-$� SAFETY GLASS, FULLY TEMPERED GLASS, � z � <br /> 16» t6" PROVIDE�ENMINIMUM CURB (ORRSELFEFLASHING � � Q <br /> A S S E M B L Y W I T H 3;1 2 M I N I M U M P I T C H O R P E R p C� � � <br /> 6x6 SHADOW BOX <br /> MANUFACTURER INSTRUC110NS). nn m <br /> o NON-STRUCT. TRIM IJfJ <br /> 50 4o XO Sv�J-�1 -' f H05E BIBBS TO BE BACKFLOW PREVEN110N AND �S w <br /> .�. � � __._ — ..��.� 5�4o PIC �( <br /> ;�;�;,,; ;,;„ ;,,,, ; , FREEZE RESISTANT TYPE. 4 <br /> ;> ,�%„�„%,�%��%,%�;,;;�%,%�%;;��5%%„%;��;,;� �����. <br /> ,, ,,,��� �%��;� W > <br /> � � ;; (2)2x6 �2HF � � � � (2)2x6 #2HF % � � � P�LL NOLDONMS. FRA�IING ANGHORS & SHEARWAL� � � � w <br /> o ; 2 % 5' TUB/SHWR % ,% � � = NAL ING MUST BE INSPEGTED BEFORF��OVFRING � <br /> �. ( ; ; SEE NOTEs %% DN 16 RISERS ; � � 2 ►-= <br /> " q � "' STAIRWAYS PER IRC R311.7 � W z <br /> i; , �i ;� �r <br /> � � ' � " � O 36' MIN. STAIRWAY WIDTH. LANDINGS SHALL v', <br /> W � <br /> �' 3 n I � HAVE A 36" MINIMUM DIMENSION IN THE � <br /> �, � ; � J o <br /> D�L'' B E D R M �3 ` �' �50 � � „ DBL � DIREC110N OF TRAVEL. A IANDING IS NOT 'c Q <br /> i� STU S'; `� ; � ,� <br /> � %% -o� % � I � % TUDS � REQUIRED WHERE THERE IS A DOOR AT THE Q' �' � <br /> � � . � %; � � % �� � � � � % � °' � � � �� � � TOP OF AN INTERIOFt FUGHT OF STAIRS, � � � <br /> � --� '% ' BATH `� I � '% ` INCLUDING STAIRS IN AN ENCLOSED GARAGE, �° O � <br /> � I ;' � ' � ;; � � � � ;� � � � � � � � � � � � � � PROVIDED THE DOOR DOES NOT SNqNG�OVER � � � 3 �U �'� <br /> i� ;, �; �� ,; <br /> ;7� � ' 3 � � ;' THE STAIRS. RISERS TO BE 7�" MAXII�UM <br /> .> �� �-9� 3'-7" ' z � ;� � �'% "' 3 <br /> ; � ,� I ;; <br /> HEIGHT AND TREADS TO BE 10" MINIMU�I <br /> �� � DEPTH, BOT}i WITH A MAXIMUM VARIA�ION OF <br /> � " ' 4 � �/ I '/ I �". TREADS Wllli SOLID RISERS TO HAVE �" � <br /> . . + I i � SA . ., 2 � �; . I I i% �. . <br /> I �� 26 ' � �� —__—-1 � � MI►JI�tUM TO lY MAX. NUSING OR 11" MINIMUM o 0 <br /> , <br /> j � A ,�'�� y.zi i; i,�,/� _J i . . <br /> ;% 6� B P ' � }� WALL UP %% OPEN RISEFtS ON S A RWAYS R S NG�MIpRE GH � � <br /> ;,'' "; " 36" A.F.F. 3'-6" 3'-8 ;; THAN 30". HANDRAIL REQUIRED IF 4 OR MORE <br /> �n � � WARD ; 5'-7" 3'-6" 7'-2. ;, <br /> .i %% � %% RISERS TO BE INSTALLED BETWEEN 34"-38" � � � <br /> � � . N � � ��� S CJL P��_� I M I M . // R . . . . . M X O � O <br /> , 2-10 2-9 , � <br /> ; I i ABOVE NOSING AND HAVE A 1Y -2 � GRIP <br /> ;,,, , „ , ,, „ , 6°BF %% `� <br /> , , , ,, , , „ ,;,, , , , .; CONTINUOUS FOR 1HE FULL LENGTH OF THE <br /> � o <br /> „ <br /> FLIGHT. RETURN ENDS TO WALL OR NEWEL � <br /> �% � � � � � i,,, %% � � � � <br /> . ^ ii a ii ( . . . . <br /> I , ,� ; ��5 WH �; INSTALL 2x10 BLOCKING BETWEEN STUDS TO o W <br /> ; ,�, sa 26 M DRY �% <br /> N / ,, ��o � SUPPORT HANDRAIL BRACKETS. FlREBLOCK � <br /> ,� <br /> BE1WEEN STUDS AT STRINGER. 6'-8" MINIMUM <br /> � ;� 2 � � ; `" ' V.T.O.S. WASH % � VERTICAL HEAD CLEARANCE. PR07ECT <br /> � ' � '� ' '% ENCLOSED ACCESSIBLE UNDER STAIR WALLS • <br /> � � � ; LINEN ;: ��`r, ' ;�' , 1 o AND CEILJNG WITH N�" GWB. U <br /> � . I j /�� T ��%/�'%�i// /%-/,//'%/%/i// %%'% // //j% � � � . . � . . <br /> O / //'%.// //�' //. � . . . <br /> M EGRESS WINDOWS PER R310 <br /> � Q X N � -, ; 28 ; ---5&p_ �; +�I'' o <br /> � � � �'' � ' � �� � � O FINISHED SILL TO BE 44" MAXIMUM ABOVE FLOOR. <br /> i� o d' t� � a ; N ' � ii i� � � � � � � � � <br /> M •- o x I ; � ; � ;; � i� NET OPENING TO BE 5.7 S.F. MINIMUM (5.0 S,F. <br /> � � B E D R M �Z - - � � ' `� � WALK—I N � % � M MINIMUM AT GRADE FLOOR), 20" MINIMUM WIDTH, � <br /> � & 24" MINIMUM HEIGHT. � <br /> `� � o � N ;�'-�o �'-s 4 WARD � ' <br /> ;; <br /> � `� o° Q � ;; 2 i � % BATHROOM NOTES `� <br /> ,.- <br /> '% "' � ;j� 9 I � ;s , � 3 FlREBLOCK TUBS AND SHOWERS PER R302.11. O a <br /> � � � � � � �;%' � �� � � ; � � � � � � � � 30"x30" MINIMUM CLEAR SPACE IN SHOWER. 22" w <br /> "" MINII�UM WIDTH SHOWER DOOR TO OPEN OUTWARD U <br /> , ,,;,% ,� _ ,, <br /> ( :, �;%� "� ��%'� � SHELVES � ;% <br /> �%,,�;,,, ,,,,��„,,,,,,,,,,,,,,,;,,,;� ,,;,,,� ,,,,,�;'� FLAT ,�% % ; i IF HINGED. 30" WIDE X 24" DEEP CLEAR SPACE o <br /> �� � � � %'��''�''�""'' '�"'"' '""'" "" " "'% I REQUIRED OUTSIDE SHOWER DOOR. ENCLOSURES a <br /> I � VAULTED �� <br /> ' 10'-7" � 2�_9� sa � 3x3 �50 � . UP 6E WITHE HOWER SUSE CEMENTB BOARD OFR CE � o <br /> / CEMENT FIBER BOARD FOR TILE BACKING. VAPOR � � <br /> // / / BARRIER NOT PERI�ITTED BEHIND W.P. GWB AT <br /> , , EE „ <br /> ;, I ; � ;; <br /> 4 % I ; �NOTES� ;;' i EXT. WALL. 2.5 GPM SHOWER FLOW RESTRICTOR. � <br /> �( � ' 24 PKT ;; TUB OR SHOWER CONTROL VALVES TO BE <br /> / I ////// // // / /, // PRESSURE BALANCE OR THERMOSTATIC MIXING w <br /> ' <br /> J �; � ' LJNEN ;% I <br /> `�I ; �,I ' ? ,';' i TYPE. 1.6 GAL PER FLUSH MAXIMUM TOILETS. 15" � <br /> R �; �I MSTR. BATH > � ;, TOILET dc 21E CLEARRSPACECREQUIRED NMFRONT. --J <br /> � <br /> I / �I x // I INS7ALL 2x10 BLOCKING FOR TOVYEt BARS UP 48" <br /> ;:, I ;% M S TR S U I TE �� 24 � � I �i ABOVE FLOOR OR BELOW SILL HE G � <br /> I HT IF AT <br /> DBL ; �� 3 % DBL WINDOW. INSTALL BLOCKING FOR T.P. HOLDERS. � � � <br /> STUD� ! ZI ; � STUDS <br /> � ;; �FULL HT."sTu�s,:w��=i s�oPEo � ; 50 ;; ATTIC ACCESS PER R807.1 <br /> '%% DBL.r=TOP�.PL.:';� BOT.;`:CHORD AF � � � � %% O 22"x30" �11NI�IUM ROUGH FRAMED OPENING. <br /> ;; �SCISSOR DO NOT BREAK;STUDS. ;: I % 36" VAN. 5 CORNER � <br /> o � �; . . � , SOAKING TUB �- � �, E LE C TR I C A L L E G E N D INSULATION �AM. 30" M N MUMDC EAR1 HEADROOM. <br /> � � y; I ; � SEE NOTES � ( � <br /> "' " ' SMOKE ALARM PER R314 & LISTED PER UL 217. FIREBLOCKING PER R302.11 � �z <br /> % I % . % INSTALL PER HOUSEHOLD WARNWG PROVISIONS OF �, �� <br /> j '�%%/���'`""" '"'"''` � NFPA 72 dc PER MFGR. SPECS. 110V HOUSEHOLD O �NSTAt1 FIREBLOCKING TO CUT OFF CONCEALED �,U; N c� <br /> „ O (2)2x4��2HF 0/ O /,,,,,, � , � , ;, „ �z <br /> ,r. . . � x r /r�,,: . . . . SA <br /> EA. NDOW a � <br /> � '%i%;;,,i;i%,%;i;,,,i;,,,,i,i,;;,. , ,„i;,�,;, „ ,� i1»'7�',%;\LI`��S p 6 17 u <br /> CURRENT WITH BATTERY BACKUP. INTERCONNECT DRAFT OPENINGS (VERT. dc HORIZ.) IN THE �_ <br /> , ,�,� ,��,�%,� ��%�%,�� 3 3 XO FOLLOWING LOCA110NS: IN CONCEALED SPACES OF I o c,>N <br /> SAF. GL EACH BEDROOM AND LEVEL ¢ <br /> �iltV--I �16 5� 3�5 n S 1 6 5� c �il,!--1. � �,�,:-i � W A L L S V E R�1 C A L L Y A T C E I L J N G & F L O O R L E V E L S, � X =3 <br /> SH 30 2oABV SH INE OF LIV R BLW ��3 75 COMBINATION SPOT & WHOLE-HOUSE EXHAUST. SEE HORIZONTALLY AT 10 �IAXIMUM INTERVALS, AT � N �� <br /> 1 6 1� 1� 1� .� � � � VENTILATION NOTES ON SEPARATE SHEEL I N T E R C O N N E C T 1 0 N S O F C O N C E A L E D V E R T 1 C A L A N D w <br /> � ABV qB -� HORIZONTAL SPACES (SOFFlTS, DROPPED CEILINGS, O >- a <br /> � 50� 50 CFM (MIN.) EXHAUST FAN - VENT TO EXTERIOR. AND COVE CEILINGS). AT OPENINGS AROUND N o � � <br /> 3� L I N E O F G A R G E L W V E N T S, P I P E S, D U C T S, C A B L E S, & W I R E S A T ►— <br /> CEIUNG & FLOOR LEVEL WITH AN APPROVED �' o� <br /> 5'-3" 18" 3'-0" 3" , 2'-0" MATERIAL TO RESIST THE PASSAGE OF RA�tE & � a Z <br /> ��-��� GAS. FIREBLOCKING TO 8E 2x LUMBER O R D O U B L E N <br /> 15'-2" 8'-10" T H I R D F L O O R P L A N S C A L E: Y" = 1'-0" -w.�.....�..... ONE KTI-IICKNESS OF z 3 Sz�W0 D STRUCTU AL �R � � �Z <br /> J � <br /> PANELS OR �" PARTICLEBOARD EITHER WI1H �3 <br /> 17'-0" 7'-0� 813 SQ. FT. THIRD FLOOR a��-��ns,oc t��rEs,t�s JOINTS BACKED BY SAME), OR N�� GWB OR Y" <br /> s3>> 2iz�r�{��a�;c�rs.w. , �— �� <br /> � 24'-0" E�,��1oNns,wA�ao2� CEMENT MILLBOARD, OR BATTS OF MINERAL WOOL o 0 <br /> (zzs��7s-2��3 OR FIRBERGLASS OR OTHER APPROVED MATERIALS <br /> SECURELY RETAINED IN PLACE. <br /> i 5TRUCTUFZAL I�EVIEW <br /> # Tf►IS DRA�ti'1*;G FIr15 Y3�E�1 C�L}/IEIVLD f�OR <br /> �S7'RC�CTURAL KLQUIfLI:IfL'N7S ONLY PEk'PlIE <br /> A'I"fAC1 iLD LE'i'I'LR A�;U/OK CALCL�LA7'[ONS <br /> -----__..�.___ <br /> �Y:..._��..��------------- 4 <br /> JOD!1:_���� DATi?_�L�'� `�dt� �I 1 i !J� �'�!L�� ! � O� <br /> VOfD 11 \O'f�b'CT SlG:V(d � <br /> - ,.�._.. r��il1�'�����;� ����� ���l��`� 8 <br />