I <br /> Drew Martin <br /> From: Drew Martin <br /> Sent: Thursday, February 4, 2021 2:28 PM <br /> To: 'rusty.cutner@rockpmservices.com' <br /> Subject: City of Everett Permit Services: 1130 West Marine View Drive (B2101-057) - First <br /> Building Intake Review <br /> Hello Mr. Cutner, <br /> Your application has been received and a permit set up. However, the submitted documents are not sufficient <br /> for us to perform a review at this time. Revised construction-level documents need to be submitted for <br /> review. Information is attached to provide guidance. Preliminary comments are provided below to assist in <br /> revising the drawings, but these are not intended to provide a comprehensive review. <br /> 1. The project involves work on an existing building and should comply with the requirements of the 2015 <br /> IEBC. The code should be listed on Sheet A-000. The documents should indicate the compliance <br /> method. The comments herein are based on the Work Area Method per Chapter 5. <br /> 2. The drawings appear to potentially be developed using recycled drawings from a previous project. If <br /> this is correct, new drawings should be produced that are specific to this project. <br /> 3. The drawing do not appear to be printed to the drafted scale. The printed drawings should be sized for <br /> the stated scales. <br /> 4. The drawings should include a key plan indicating the location of the work area in the building. <br /> 5. The drawings generally appear to shoW the final condition of the building. Drawings showing the <br /> existing conditions and the proposed demolition should be provided. <br /> 6. The drawings have not been prepared using standard drafting practices to delineate between new and <br /> existing construction and should be revised. <br /> 7. The plans appear to include the construction of new walls. Details for the wall construction including <br /> top and bottom connections to the supporting structure should be provided. The walls and <br /> connections should be designed for a minimum out-of-plane loading of 5 psf. <br /> 8. The partial plans provided on the 200-series sheets are oversized and do not provide useful <br /> information. It is recommended that these be removed, or reduced and revised to show information <br /> that is not provided in the plans. <br /> 9. Exit signage is required to provide a back-up power system with a minimum 90-minute duration. <br /> 10. The plans on Sheets A-001 and A-100 have inconsistencies, such as but not limited to the position of <br /> the bathroom door in the existing warehouse. The plans should be reviewed and revised as needed. <br /> 11. The proposed work requires compliance with the accessibility requirements of ICC A117.1-09. The <br /> drawings do not provide sufficient information to satisfy the requirements. Apparent inaccessible areas <br /> include but are not limited to:the existing bathrooms,the existing break room,the room adjacent to <br /> the existing break room, and the parking. <br /> 12. The building involves at least a Level 2 modification per IEBC Chapter 8. Accessibility improvements <br /> per Section 705.2 are required. Documentation substantiating_compliance with this section are <br /> required. <br /> 13. Exhaust fans are required in all restrooms. <br /> 14. The plan on Sheet A-100 appears to show a new canopy above the east exterior door for the <br /> warehouse. Details and calculations for the canopy are required. Note that the canopy is not shown in <br /> available aerial photography of the building. <br /> i <br />