My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
543 VIEW RIDGE DR 2022-03-14
>
Address Records
>
VIEW RIDGE DR
>
543
>
543 VIEW RIDGE DR 2022-03-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/14/2022 12:35:19 PM
Creation date
9/4/2020 3:13:08 PM
Metadata
Fields
Template:
Address Document
Street Name
VIEW RIDGE DR
Street Number
543
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
e <br />ARCHITECTURAL DESIGN <br />ASSOCIATES, PS <br />5-19-2016 <br />To: Jeff Heilman, Development Technician <br />City of Everett / Engineering Public Services Department <br />3200 Cedar Street, Everett, WA 98201 <br />Re: J & C No. 3 LLC <br />543 View Ridge Drive <br />Everett, WA. 98203 <br />Dear Mr. Heilman <br />Pursuant to your April 26, 2016 letter, We have made the folllp i+Kjcorrections to the plans <br />for the above address. Revisions have been clouded on the plans. We have riesponded to your <br />comments by the comment number and referred the responses to appropriate plan sheet number <br />or document revised. <br />1. SHEETS A -3.3 . A-5.4 Roof Drains, with overflows have been altered to show the <br />directed roof run off. The roofing crickets will be rigid insulation applied to <br />direct roof run off to the roof drains with overflows as shown. <br />Note that the revised roof design now includes cantilevered truss ends and a <br />mechanical enclosure not shown on the previous submittal. <br />A wall section detail and roof drain details have been added RE: sheet A-4.0 & A-5.4 <br />2. SHEETS A -1 0 A-1 1 A-3.2 A-3 3 The high glulam beam #2 is now shown as a <br />wall which is part of a new mechanical enclosure on the revised building elevations. <br />The 38' long high beam# 2 has been redrawn properly to reflect it's adjacency to the <br />cantilevered beam # 3 supporting the porch roof. <br />The mechanical enclosure is shown on the elevations and roof plan. <br />3. SHEET A-3.2 High beam# 2 has been extended beyond its original bearing point to <br />,handle the wall above going from 34' to 38' long. <br />4. SHEET A-2.0 Added a 50 CFM fan in the master bath in the vicinity of the shower <br />and free standing tub <br />5. SHEET A-6.0 Revised/added notations on A-6.0 2012 WSEC Compliance section to <br />include the detailed requirements for the energy credits <br />6. SHEET A-6.0. A-2.0 Revised furnace notations on A-2.0 & updated Whole House <br />Ventilation section on A-6.0 to a system integrated with a forced air heating system. <br />7. SHEET A-3.0 and A-4.0,,Footings modified and notations added on foundation plan <br />referenced to added pilaster detail/sections on sheet A-4.0 <br />Sincerely, <br />James Thomas, Architect <br />Architectural Design Associates, PS <br />2221 Everett Ave # 104, <br />Everett, WA. 98201 <br />425-259-0661 <br />jthomas@arch-design.net <br />D <br />U <br />MAY 31 2016 <br />CFe1T' (�F EVERETT <br />rmi f ServiCes <br />2221 EVERETTAVENUESUITE #201 - EVERETT,WA98201 <br />Phone_ (425) 259-0661 - Fax: (425) 252-6911 - www.arch-design.net <br />
The URL can be used to link to this page
Your browser does not support the video tag.