Laserfiche WebLink
� _. T .. _ _. _ _ ___. _ <br /> , <br /> GENERAL NOTES <br /> 1, ALL NEW PARTITIONS TO BE WALL TYPE 1B UON, SEE SHEET A8.1 FOR WALL <br /> TYPES, <br /> 2. FINISHES PER ROOM FINISH SCHEDULE SHEET A6.1,TYPICAL UON. N2IC0 ArCI1lteCtUfe� 111C. <br /> 3. FOR ACCESSIBILITY COMPLIANCE REFER TO SHEET T1.2. <br /> 4. CONFLICTS BETWEEN SITE CONDITIONS AND DRAWINGS SHALL BE BROUGHT <br /> TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. <br /> 5. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL,SQUARE AND <br /> TRUE AND IN PROPER ALIGNMENT, U.N.O. 1200 Fifth Ave. <br /> 6. ALL DIMENSION5 ARE TO FACE OF FRAMING, U.N.O. DIMENSIONS NOTED Suite 1300 <br /> "HOLD" MUST BE ACCURATELY MAINTAINED, AND SHALL NOT VARY MORE THAN Seattle, WA 98101 <br /> f 1/8" WITHOUT WRITTEN INSTRUCTION FROM ARCHITECT. "ALIGN" MEANS phone: (206)408-8500 <br /> TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLANE. DIMENSIONS <br /> NOTED "CLEAR" ARE MINIMUM DIMENSIONS WHICH MUST BE MAINTAINED WWW•NELSONWORLDWIDE.COM <br /> WITHOUT EXCEPTION. DIMENSIONS MARKED t MEAN A VARIANCE NOT <br /> GREATER THAN 1 INCH,VERIFY DIMENSIONS EXCEEDING TOLERANCE WITH <br /> THE ARCHITECT. ALL DIMENSIONS TO THE EXTERIOR WINDOW WALL ARE TO <br /> THE FINISH FACE OF WALL BELOW SILL, U.N.O. <br /> 7. WHERE NEW FLOOR FINISHES AND/OR WALL BASE ARE SCHEDULED, PREPARE <br /> FLOORS AND WALLS TO RECEIVE NEW FINISH. CONCRETE SLAB TO RECEIVE <br /> NEW SEAL WHERE SAW-CUT AND PATCHED. PATCH AND PAINT ALL OFFICE <br /> WALLS. TYPICAL THROUGHOUT. <br /> 8. ALL EXISTING FLOORS, PARTITIONS, DEMISING WALLS, AND CORRIDOR WALLS <br /> TO REMAIN ARE TO BE PATCHED AND REPAIRED TO MATCH ADJACENT <br /> SURFACES. <br /> 9. PATCH AT ALL NEW AND EXISTING PENETRATIONS AT FLOOR AND CEILING <br /> SLABS, WALLS AND SHAFTS, SEAL ABANDONED PENETRATIONS AT FLOORS, <br /> WALLS AND SHAFfS TO MAINTAIN FIRE/SMOKE AND ACOUSTICAL RATINGS. <br /> PATCH FIREPRGOFING AT ALL NEW AND EXISTING LOCATIONS WITH EXPOSED <br /> STRUCTURAL STEEL. <br /> 10, ALL INFILL OF DOOR5/WALLS/OPENINGS SHALL MATCH AND BE FLUSH WITH <br /> EXISTING ADJACENT PARTITION CONSTRUCTION. FINISHED FACES OF NEW <br /> PARTITIONS PARALLEL TO EXISTING FRAMING SHALL ALIGN. <br /> 11. WHERE NEW PARTITIONS ABUT EXISTING SURFACES, REMOVE EXISTING <br /> CORNER BEAD AND PROVIDE SMOOTH FINISH AT INTERSECTION. <br /> 12, PROVIDE FURRING AT EXISTING PARTITIONS AS REQUIRED TO INSTALL <br /> ELECTRICAL ITEMS AS INDICATED ON THE DRAWINGS. <br /> 13. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH <br /> NO VISIBLE JOINTS. PROVIDE LEVEL 4 FINISH, U.N.O. - REFER TO MATERIAL <br /> SCHEDULE & FINISH PLAN FOR MATERIALS&LOCATIONS THAT REQUIRE A <br /> LEVEL 5 FINISH, U.N.O. <br /> 14. GYPSUM WALLBOARD AT BOTH SIDES OF ALL PARTITIONS WITH PLUMBING <br /> \ ROUGH-IN (E.G.BATHROOMS, PANTRY,JANITOR'S CLOSET,WET COLUMNS) � <br /> SHALL BE WATER-RESISTANT. <br /> 15. METAL STUDS AT PARTITIONS TO RECEIVE CERAMIC TILE ARE TO BE 20 GAUGE <br /> (MINIMUM) @ 16" O.C. (MAXIMUM). REFER TO THE FINISH PLANS FOR TILE �; ': <br /> LOCATIONS. � �s <br /> a���� <br /> , 1 16. ALL EXPOSED GYPSUM BOARD EDGES TO HAVE VINYL OR METAL EDGE TRIM. <br /> A5-1 1 � �� � �� � �� i � �� 1 � �� 17. THE CONTRACTOR SHALL ESTABLISH A SINGLE FLOOR ELEVATION THAT IS TO P A N A T T O N I� <br /> I \ 12 '6 5 -O H -O 17 'S 13 -7 BE USED TO SET THE TOP OF ALL DOORS SUCH THAT THE TOP OF ALL DOORS <br /> OF THE SAME HEIGHT WILL ALIGN REGARDLESS OF VARIATIONS IN THE FLOOR pANATTONI <br /> SLAB OR FINISHED FLOOR THICKNESS. THERE SHALL BE NO EXPOSED PIPE, <br /> CONDUIT, DUCTS,VENTS, ETC. ALL SUCH LINES SHALL BE CONCEALED OR <br /> ; � - - � � � � � i FURRED AND FINISHED, UNLESS OTHERWISE NOTED AS EXPOSED DEVELOPMENT <br /> I' � 1p2 -\'j ( 102B 110 CGNSTRUCTION ON THE DRAWING. <br /> 18. DOOR AND CASED OPENINGS WITHOUT LOCATION DIMENSIONS OR DEfAILS CO M PANY, LLC <br /> � — I � I ARE TO BE (4) INCHES FROM ADJACENT WALL AT HINGE SIDE OF DOOR OR g00 SW 16TH STREET SUITE 330 <br /> o O � � , I I 4 CENTERED BETWEEN WALLS. � <br /> I I � I � 19, CENTER LOCATION OF NEW WALL CONSTRUCTION ON EXISTING COLUMNS, RENTON, WA, 98057 <br /> I � � � ,; PIER,JOISTS OR WINDOW MULLION, AS SHOWN. <br /> I I � -- — � 7 ? 20. GC SHALL BE RESPONSIBLE FOR PROVIDING ALL BLOCKING FOR ALL WALL AND <br /> I I I I OFFICE ��� � CEILING MOUNTED ITEMS, INCLUDING HARDWARE, LIGHT FIXTURES, GRAB G L A C I E R P E A K - <br /> N � - - � BARS, CASEWORK, AND ALL OWNER PROVIDED ITEMS. PROVIDE SHEET METAL <br /> _, /_ _ _ � � - - - -� 110 REINFORCING (8"HORIZONTALLY MOUNTED STRIP OF 20 GA. GALVANI2ED GREAT LITTLE BOX <br /> � I OMEN'S/TOILET \ I � BREAK ROOM SHEET METAL) CONCEALED IN PARTITIONS WHERE WALL OR CEILING <br /> I � 105 � I I I 106 MOUNTED ITEM IS INDICATED ON DRAWINGS, ALL CONCEALED LUMBER AND <br /> BLOCKING TO BE FIRE TREATED. WHERE BLOCKING OR ADDITIONAL STUDS <br /> \\ � �0 I ARE REQUIRED AT EXISTING PARTITIONS,THEY ARE TO BE PATCHED AND 607 RIVERSIDE ROAD <br /> I � // I� -� 21. REUSE EXDISTING DOORS, DOOR FRAMES AND DOOR HARDWARE IN NEW EVERETT, WA 98201 <br /> � �\ CONFIGURATION WHENEVER POSSIBLE. NEW DOORS AND DOOR FRAMES TO Description: No: Date: <br /> / I� 109 MATCH EXISTING. PERMIT SET 02/14/2020 <br /> � / �� � 104 � � � <br /> I ME�i�s Toi�� � � � � ,� �3 5 LEGEND <br /> - ( — — — 104 � � � 4 <br /> 0 <br /> � <br /> _ _ _ _ \ � I I A5.1 OPEN OFFICE FFICE <br /> N �I �� - - - -I� 102 � 109 EXISTING PARTITION TO REMAIN <br /> I � — � � <br /> � I <br /> I I NEW PARTITION <br /> I I � I � <br /> I 3 I � <br /> I � I — � I I N EW DOOR; <br /> � l 106 � � � � x DOOR TYPE, SEE SHEET A9-1 <br /> — — — � — — — — — <br /> O Q <br /> `� d- � oFF�os � � KEY NOTES � <br /> U <br /> � 1. EXISTING STOREFRONT SYSTEM AND ACCESSIBLE ENTRY DOOR <br /> ��_4�� <br /> � 2. NEW PLASTIC LAMINATE COUNTERTOP, BASE &UPPER CABINETS WITH SINGLE <br /> AH-1 COMPARTMENT, TOP MOUNT SINK. <br /> o RECEPTION ios nP <br /> C� 3. PROVIDE WATER SUPPLY LINE FOR NEW (FOIO) PLUMBED FiOT/COLD WATER <br /> 4 � 101 _ <br /> DISPENSER, 1/4" COPPER TUBES BELOW COUNTER. <br /> � <br /> CONFERENCE 2�_1�� 107 4. PROVIDE WATER SUPPLY LINE TO(FOIO) REFRIGERATORS, 1/4" COPPERTUBES <br /> ' 103 ' <br /> BELOW COUNTER. <br /> ' OFFICE 1°�� <br /> 107 5. PROVIDE WATER SUPPLY LINE TO (FOIO)COFFEE MAKER, 1/4" COPPER TUBES AE�C-�H,�RED <br /> BELOW COUNTER. <br /> 6. SURFACE MOUNTED TELEVISION AND MOUNTING HARDWARE, (FOIO). GC pM �G L <br /> _ PROVIDE BACKING IN WALL: 8'-0" W X 4'-0" H, BOTTOM @ 4'-0"AFF. STATE OF WASfjill��TON <br /> � � , <br /> ^ 7. CHANGE IN FLOOR FINISH FLUSH <br /> � � . <br /> � 103 <br /> � i <br /> . � ' <br /> - � �� l �s r��.��,�, ;: �� <br /> _ .� _ � .�,s .sl�n,� <br /> ( <br /> �� <br /> FLOOR PLAN <br /> Proj. No: 19.0005640.000 Reviewed By: PA/PM <br /> i�� FIRST FLOOR PLAN � <br /> ` A2.1 ' 1/4"=1'-0° � 2 4 8 <br /> �� <br /> SCALE: 1/4" = 1'-0" A ■ 1 <br /> - � <br />