<br /> GENERAL NOTES
<br /> 1, ALL NEW PARTITIONS TO BE WALL TYPE 1B UON, SEE SHEET A8.1 FOR WALL
<br /> TYPES,
<br /> 2. FINISHES PER ROOM FINISH SCHEDULE SHEET A6.1,TYPICAL UON. N2IC0 ArCI1lteCtUfe� 111C.
<br /> 3. FOR ACCESSIBILITY COMPLIANCE REFER TO SHEET T1.2.
<br /> 4. CONFLICTS BETWEEN SITE CONDITIONS AND DRAWINGS SHALL BE BROUGHT
<br /> TO THE IMMEDIATE ATTENTION OF THE ARCHITECT.
<br /> 5. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL,SQUARE AND
<br /> TRUE AND IN PROPER ALIGNMENT, U.N.O. 1200 Fifth Ave.
<br /> 6. ALL DIMENSION5 ARE TO FACE OF FRAMING, U.N.O. DIMENSIONS NOTED Suite 1300
<br /> "HOLD" MUST BE ACCURATELY MAINTAINED, AND SHALL NOT VARY MORE THAN Seattle, WA 98101
<br /> f 1/8" WITHOUT WRITTEN INSTRUCTION FROM ARCHITECT. "ALIGN" MEANS phone: (206)408-8500
<br /> TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLANE. DIMENSIONS
<br /> NOTED "CLEAR" ARE MINIMUM DIMENSIONS WHICH MUST BE MAINTAINED WWW•NELSONWORLDWIDE.COM
<br /> WITHOUT EXCEPTION. DIMENSIONS MARKED t MEAN A VARIANCE NOT
<br /> GREATER THAN 1 INCH,VERIFY DIMENSIONS EXCEEDING TOLERANCE WITH
<br /> THE ARCHITECT. ALL DIMENSIONS TO THE EXTERIOR WINDOW WALL ARE TO
<br /> THE FINISH FACE OF WALL BELOW SILL, U.N.O.
<br /> 7. WHERE NEW FLOOR FINISHES AND/OR WALL BASE ARE SCHEDULED, PREPARE
<br /> FLOORS AND WALLS TO RECEIVE NEW FINISH. CONCRETE SLAB TO RECEIVE
<br /> NEW SEAL WHERE SAW-CUT AND PATCHED. PATCH AND PAINT ALL OFFICE
<br /> WALLS. TYPICAL THROUGHOUT.
<br /> 8. ALL EXISTING FLOORS, PARTITIONS, DEMISING WALLS, AND CORRIDOR WALLS
<br /> TO REMAIN ARE TO BE PATCHED AND REPAIRED TO MATCH ADJACENT
<br /> SURFACES.
<br /> 9. PATCH AT ALL NEW AND EXISTING PENETRATIONS AT FLOOR AND CEILING
<br /> SLABS, WALLS AND SHAFTS, SEAL ABANDONED PENETRATIONS AT FLOORS,
<br /> WALLS AND SHAFfS TO MAINTAIN FIRE/SMOKE AND ACOUSTICAL RATINGS.
<br /> PATCH FIREPRGOFING AT ALL NEW AND EXISTING LOCATIONS WITH EXPOSED
<br /> STRUCTURAL STEEL.
<br /> 10, ALL INFILL OF DOOR5/WALLS/OPENINGS SHALL MATCH AND BE FLUSH WITH
<br /> EXISTING ADJACENT PARTITION CONSTRUCTION. FINISHED FACES OF NEW
<br /> PARTITIONS PARALLEL TO EXISTING FRAMING SHALL ALIGN.
<br /> 11. WHERE NEW PARTITIONS ABUT EXISTING SURFACES, REMOVE EXISTING
<br /> CORNER BEAD AND PROVIDE SMOOTH FINISH AT INTERSECTION.
<br /> 12, PROVIDE FURRING AT EXISTING PARTITIONS AS REQUIRED TO INSTALL
<br /> ELECTRICAL ITEMS AS INDICATED ON THE DRAWINGS.
<br /> 13. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH
<br /> NO VISIBLE JOINTS. PROVIDE LEVEL 4 FINISH, U.N.O. - REFER TO MATERIAL
<br /> SCHEDULE & FINISH PLAN FOR MATERIALS&LOCATIONS THAT REQUIRE A
<br /> LEVEL 5 FINISH, U.N.O.
<br /> 14. GYPSUM WALLBOARD AT BOTH SIDES OF ALL PARTITIONS WITH PLUMBING
<br /> \ ROUGH-IN (E.G.BATHROOMS, PANTRY,JANITOR'S CLOSET,WET COLUMNS) �
<br /> SHALL BE WATER-RESISTANT.
<br /> 15. METAL STUDS AT PARTITIONS TO RECEIVE CERAMIC TILE ARE TO BE 20 GAUGE
<br /> (MINIMUM) @ 16" O.C. (MAXIMUM). REFER TO THE FINISH PLANS FOR TILE �; ':
<br /> LOCATIONS. � �s
<br /> a����
<br /> , 1 16. ALL EXPOSED GYPSUM BOARD EDGES TO HAVE VINYL OR METAL EDGE TRIM.
<br /> A5-1 1 � �� � �� � �� i � �� 1 � �� 17. THE CONTRACTOR SHALL ESTABLISH A SINGLE FLOOR ELEVATION THAT IS TO P A N A T T O N I�
<br /> I \ 12 '6 5 -O H -O 17 'S 13 -7 BE USED TO SET THE TOP OF ALL DOORS SUCH THAT THE TOP OF ALL DOORS
<br /> OF THE SAME HEIGHT WILL ALIGN REGARDLESS OF VARIATIONS IN THE FLOOR pANATTONI
<br /> SLAB OR FINISHED FLOOR THICKNESS. THERE SHALL BE NO EXPOSED PIPE,
<br /> CONDUIT, DUCTS,VENTS, ETC. ALL SUCH LINES SHALL BE CONCEALED OR
<br /> ; � - - � � � � � i FURRED AND FINISHED, UNLESS OTHERWISE NOTED AS EXPOSED DEVELOPMENT
<br /> I' � 1p2 -\'j ( 102B 110 CGNSTRUCTION ON THE DRAWING.
<br /> 18. DOOR AND CASED OPENINGS WITHOUT LOCATION DIMENSIONS OR DEfAILS CO M PANY, LLC
<br /> � — I � I ARE TO BE (4) INCHES FROM ADJACENT WALL AT HINGE SIDE OF DOOR OR g00 SW 16TH STREET SUITE 330
<br /> o O � � , I I 4 CENTERED BETWEEN WALLS. �
<br /> I I � I � 19, CENTER LOCATION OF NEW WALL CONSTRUCTION ON EXISTING COLUMNS, RENTON, WA, 98057
<br /> I � � � ,; PIER,JOISTS OR WINDOW MULLION, AS SHOWN.
<br /> I I � -- — � 7 ? 20. GC SHALL BE RESPONSIBLE FOR PROVIDING ALL BLOCKING FOR ALL WALL AND
<br /> I I I I OFFICE ��� � CEILING MOUNTED ITEMS, INCLUDING HARDWARE, LIGHT FIXTURES, GRAB G L A C I E R P E A K -
<br /> N � - - � BARS, CASEWORK, AND ALL OWNER PROVIDED ITEMS. PROVIDE SHEET METAL
<br /> _, /_ _ _ � � - - - -� 110 REINFORCING (8"HORIZONTALLY MOUNTED STRIP OF 20 GA. GALVANI2ED GREAT LITTLE BOX
<br /> � I OMEN'S/TOILET \ I � BREAK ROOM SHEET METAL) CONCEALED IN PARTITIONS WHERE WALL OR CEILING
<br /> I � 105 � I I I 106 MOUNTED ITEM IS INDICATED ON DRAWINGS, ALL CONCEALED LUMBER AND
<br /> BLOCKING TO BE FIRE TREATED. WHERE BLOCKING OR ADDITIONAL STUDS
<br /> \\ � �0 I ARE REQUIRED AT EXISTING PARTITIONS,THEY ARE TO BE PATCHED AND 607 RIVERSIDE ROAD
<br /> I � // I� -� 21. REUSE EXDISTING DOORS, DOOR FRAMES AND DOOR HARDWARE IN NEW EVERETT, WA 98201
<br /> � �\ CONFIGURATION WHENEVER POSSIBLE. NEW DOORS AND DOOR FRAMES TO Description: No: Date:
<br /> / I� 109 MATCH EXISTING. PERMIT SET 02/14/2020
<br /> � / �� � 104 � � �
<br /> I ME�i�s Toi�� � � � � ,� �3 5 LEGEND
<br /> - ( — — — 104 � � � 4
<br /> 0
<br /> �
<br /> _ _ _ _ \ � I I A5.1 OPEN OFFICE FFICE
<br /> N �I �� - - - -I� 102 � 109 EXISTING PARTITION TO REMAIN
<br /> I � — � �
<br /> � I
<br /> I I NEW PARTITION
<br /> I I � I �
<br /> I 3 I �
<br /> I � I — � I I N EW DOOR;
<br /> � l 106 � � � � x DOOR TYPE, SEE SHEET A9-1
<br /> — — — � — — — — —
<br /> O Q
<br /> `� d- � oFF�os � � KEY NOTES �
<br /> U
<br /> � 1. EXISTING STOREFRONT SYSTEM AND ACCESSIBLE ENTRY DOOR
<br /> ��_4��
<br /> � 2. NEW PLASTIC LAMINATE COUNTERTOP, BASE &UPPER CABINETS WITH SINGLE
<br /> AH-1 COMPARTMENT, TOP MOUNT SINK.
<br /> o RECEPTION ios nP
<br /> C� 3. PROVIDE WATER SUPPLY LINE FOR NEW (FOIO) PLUMBED FiOT/COLD WATER
<br /> 4 � 101 _
<br /> DISPENSER, 1/4" COPPER TUBES BELOW COUNTER.
<br /> �
<br /> CONFERENCE 2�_1�� 107 4. PROVIDE WATER SUPPLY LINE TO(FOIO) REFRIGERATORS, 1/4" COPPERTUBES
<br /> ' 103 '
<br /> BELOW COUNTER.
<br /> ' OFFICE 1°��
<br /> 107 5. PROVIDE WATER SUPPLY LINE TO (FOIO)COFFEE MAKER, 1/4" COPPER TUBES AE�C-�H,�RED
<br /> BELOW COUNTER.
<br /> 6. SURFACE MOUNTED TELEVISION AND MOUNTING HARDWARE, (FOIO). GC pM �G L
<br /> _ PROVIDE BACKING IN WALL: 8'-0" W X 4'-0" H, BOTTOM @ 4'-0"AFF. STATE OF WASfjill��TON
<br /> � � ,
<br /> ^ 7. CHANGE IN FLOOR FINISH FLUSH
<br /> � � .
<br /> � 103
<br /> � i
<br /> . � '
<br /> - � �� l �s r��.��,�, ;: ��
<br /> _ .� _ � .�,s .sl�n,�
<br /> (
<br /> ��
<br /> FLOOR PLAN
<br /> Proj. No: 19.0005640.000 Reviewed By: PA/PM
<br /> i�� FIRST FLOOR PLAN �
<br /> ` A2.1 ' 1/4"=1'-0° � 2 4 8
<br /> ��
<br /> SCALE: 1/4" = 1'-0" A ■ 1
<br /> - �