Laserfiche WebLink
. . _ � � � r • . , <br /> � <br /> � . � . � - . � . .`r ' <br /> ' . <br /> BERC2 CLIP POP RIVET <br /> 2 x 2 SUPPLY 2 x 4 FLUORESCENT <br /> AIR DIFFUSER TROFFER <br /> n <br /> �n CROSS TEE CROSS TEE �' � . <br /> ;� . <br /> #8 x 1/2" ROUND WASHER <br /> HEAD TEK SCREW WALL ANGLE � ' � <br /> (SELF- TAPPING) <br /> NOTE: SCREW IS NOT - - - - � <br /> WALL ANGLE TIGHTENED DOWN AGAINST <br /> BERC2 CLIP � <br /> U N ATTACH ED WALL ATTACH ED WALL � <br /> (TWO ADJACENT WALLS) (TW0 ADJACENT WALLS) � <br /> r <br /> SEISMIC BERC2 CLIP <br /> -FACTORY INSTALLED AT TWO ADJACENT WALLS. � <br /> � -SCREW TIGHTENED FOR SHIPPING IN ROOMS WHERE � \� <br /> CEILING CROSSES MOD LINE, LOOSEN SCREW ON SITE �-� <br /> BY SET UP CREW � ' <br /> SUSPENDED CEILING GRID BERC2 CLIPS M-� <br /> sEisnnic ATTACHnnENT AT wA��s REFLECTED CEILING PLAN � . � <br /> 3„ — �'—o" SYSTEM (E R 1308)] /Rx' SUSPENSION <br /> �/8�, _ �'-p„ <br /> • , <br /> � MECHANICAL NOTES: - <br /> 1. DUCT MATERIAL IS 26 GA. GALV. AND FLEX DUCT. DUCTWORK SHALL BE SUPPORTED PER IMC . � � <br /> CHAPTER 6. SECTION 603 <br /> 2. MATERIAL IN DUCTS SHALL HAVE A FLAME SPREAD INDEX OF LESS THAN 25, SMOKE DEVELOPMENT <br /> OF 50 PER IMC CHAPTER 6. SECTION 602 � , <br /> SUPPLY AIR <br /> 3. LOW PRESSURE DUCT SYSTEMS SHALL HAVE LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND P�ENUM #PWso15 � <br /> CONNECTIONS OF SUPPLY AND RETURN DUCTS AND PLENUMS SECURELY FASTENED AND SEALED WITH �2�'0,�0 <br /> WELDS, GASKETS, MASTICS (ADHESIVES), MASTIC-PLUS EMBEDDED-FABRIC SYSTEMS OR APPROVED TAPES � 12 <br /> INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS 10 10 12 <br /> , 4. WHEN ISOLATION SLEEVES ARE USED AT LINE CONNECTIONS TO PLENUMS, THEN THEY SHALL COMPLY __ _ _ 12 1�/ - � - -- <br /> - - -- - ------ <br /> 3 TON 10 kw <br /> WITH IMC CHAPTER 6 <br /> HEAT PUMP <br /> 5. 10" DIFFUSERS WITH NO MANUAL DAMPERS. USE FLOW CONTROLS AT WYES, TYPICAL AS NOTED ON PLAN w/ ECONOMIZER , . <br /> 1100 cfm MAX <br /> 6. MINIMUM 390 CFM OUTSIDE AIR REQUIRED PER IMC CHAPTER 4 <br /> 7. OUTSIDE AIR DAMPERS SHALL COMPLY WITH WSEC • , <br /> 8. SINGLE PACKAGE UNITARY FAN COOLING UNITS HAVING A TOTA� COOLING CAPACITY OF GREATER THAN <br /> 20,000 Btu/h REQUIRE ECONOMIZERS PER WSEC <br /> 9. THE BUILT-IN ECONOMIZER SYSTEM IS INTERNALLY MOUNTED BEHIND THE SERVICE DOOR AND ALLOWS <br /> UP TO 100� OUTSIDE AIR THRU THE AIR INLET OPENINGS. IT INCLUDES A BUILT-IN EXHAUST AIR <br /> , DAMPER. THE ECONOMIZER IS DESIGNED TO PROVIDE "FREE COOLING" WHEN THE o�TS�oE A�R M E C HAN I CAL P LAN <br /> TEMPERATURE IS COOL ENOUGH TO PROVIDE NEEDED COOLING WITHOUT USING THE COMPRESSOR. <br /> THIS IN TURN PROVIDES LOWER OPERATING COSTS, WHILE EXTENDING THE LIFE OF THE COMPRESSOR <br /> 1�8" = 1'-0" • <br /> QTY. SIZE DESCRIPTION � • <br /> H.V.A.C. 1 3 TON 10 kW BARD WALL HUNG HEAT PUMP w/ ECONOMIZER <br /> �NDOOR THERMOSTAT HONEYWELL w/ MICROPROCESSOR— 7 DAY PROGRAMMABLE <br /> � VISIONPRO #TH8320U AUTOMATIC SETBACK— DEADBAND CONTROL <br /> - OUTDOOR THERMOSTAT � CMH-14A <br /> COPYRIGHT 2016, BLAZER INDUSTRIES, wc. � MODULAR Classroom for.� Approved for Const: Job No. 18567 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY <br /> � OF BLAZER INDUSTRIES, INC.AND SHALL �� 28 X 32 KC DA - Eve rett S■D■ File Copy: <br /> NOT BE REPRODUCED, USED, OR DISCLOSED .: INDUSTRIES,iNc. • <br /> . TO OTHERS EXCEPT AS AUTHORIZED BY THE Drawn By: JwR � <br /> �� www.blazerind.com �/A. GOLD Pacific Mobile 14 BLMP-11 A3 Everett WA <br /> DATE REVISION BY WRITI'EN PERMISSION OF BLAZER INDUSTRIES. �� P.O.BOX 489 ■ Aumsvi�le,OR 97325-0489 � Issue Date: 02/01/16 <br />