My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2215 PINE ST 2020 Plans 2022-11-07
>
Address Records
>
PINE ST
>
2215
>
Plans
>
2215 PINE ST 2020 Plans 2022-11-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2022 4:04:45 PM
Creation date
10/30/2020 9:00:30 AM
Metadata
Fields
Template:
Address Document
Street Name
PINE ST
Street Number
2215
Permit
B2004-013
Year
2020
Notes
RELOCATION OF 28X32 PROTABLE CLASSROOM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
..iL,� . � . <br /> — -------�----- <br /> � <br /> � , <br /> H V A C (MOTOR COMPRESSOR, HEATER SIZES) '. <br /> OPERATION VOLTAGE 197 MIN. 253 MAX. <br /> COMPRESSOR 14.7 RLA 112 LRA � <br /> ' INDOOR BLOWER FAN 2.2 FLA 1�3 HP <br /> OUTDOOR BLOWER FAN 1.5 FLA 1�5 HP <br /> �' � HEAT STRIP 10 KVA 240 VOLT ' • � <br /> MINIMUM CIRCUIT AMPS S') AMPS <br /> MAXIMUM OVERCURRENT PROTECTION JO AMPS <br /> (2) 8' x 4' WHITE BOARDS w/ � , <br /> MARKER TRAY SHIP LOOSE OVERCURRENT PROTECTION SHALL BE DUAL ELEMENT , <br /> � � ELECTRIC TIME DELAY FUSE OR HACR CIRCUIT BREAKER <br /> INSTALLED ON SITE BY OTHERS PANEL � <br /> � . <br /> B B B PANEL SCHEDULE : <br /> #� NOTE:ALL CONDUCTORS COPPER. 200 AMP 1� 22,000 AIC <br /> WP <br /> ' GFCI C� TRIP WIRE VOLT 20O VOLT WIRE TRIP CKT � <br /> DESCRIPTION DESCRIPTION <br /> NO. AMPS SIZE AMPS ��/.� B�� AMPS SIZE AMPS N0. <br /> � LIGHTS 20 12 792 — — 7208 4 90 HVAC 2 , <br /> Q� 3 RECEPTACLES 20 12 1260 �� �� 72a8 / � / 4 <br /> z z 5 RECEPTACLES 20 12 1080 �� �� •- — 20 SPARE 6 , <br /> p J 7 RECEPTACLES 20 12 972 �� �� — — 20 SPARE 8 <br /> �o- �2�4 g S=','.CE — — — �� �� — — 20 SPARE 10 <br /> C r�j� 11 ;?.,;�,�E — _. _ /"\ �1 — — 20 SPARE 12 � . <br /> C�Q 13 `.>i','.CE — — _ �\ �\ — — 20 SPARE 14 . <br /> B z� 15 =;:��GE �� �� — 20 SPARE 16 <br /> B B — — � �� �-� — — <br /> 17 �::,;�;E — — 20 SPARE 18 ' . <br /> - - - - - - - - T - — �1 �'1 : <br /> — - - - - - - - �g ;;���� - - _ - - -- - 20 SPARE 20 <br /> \ / • <br /> \ / , <br /> ELECTRICAL PLAN REVIEW <br /> � . . <br /> �� LOAD CALCULATIONS <br /> \, \ \ , <br /> VOLTAGE: 120/240 PHASE: 1� <br /> DAYLIGHTWG � � . <br /> ` CONNECTEDLOAD CALC. LOAD <br /> _ _' A P A Pg, � <br /> ; � � LIGHTWG <br /> \ <br /> i � � EXTERIOR 72 VA x 125 % = 90 VA � <br /> INTERIOR 792 VA x 125 % - 990 VA <br /> - SECONDARY — <br /> �� RECEPTACLES <br /> � B�A j THRU 10,000 3240 VA x 100 % = 3240 VA ' • <br /> _____...._..._._..__.__ ' _._...._......._..____....._.... 0 VA <br /> OVER 10,000 0 VA x 50 % _ • <br /> ; MOTORS, COMPR. <br /> PRIMARY TOTAL 4416 VA x 100 % = 4416 VA ' , <br /> LARGEST (3528) VA x 25 % = 882 VA <br /> HEATING 1000o vA x 100 / _ �o00o va � <br /> NOTEs: L P LA N <br /> ELECTRICA <br /> ' 1. WHEN STRANDED WIRE IS USED,ALL TERMINATIONS ARE MADE - TOTAL KVA 18.52 TOTAL KVA 1 9.62 <br /> BY A PRESSURE TERMINAL, BY TAILING OFF WITH SOLID 1 4" = 1'-0" ARS 2/1/16 CONNECTED CALCULATED : <br /> � LOAD AMPS 77.17 <br /> LOAD AMPS 81 .74 <br /> CONDUCTORS OR OTHER APPROVED MEANS OF TERMINATION. • <br /> 2. ALL CONDUCTORS ARE COPPER;TYPE THHN. <br /> E L E C T R I C A L S Y M B O L S <br /> 3. RATING OF STANDARD PANEL IS 22,000 A.I.C. . <br /> HEIGHT <br /> SYMBOL DESCRIPTION TO TOP REMARKS ' <br /> 4. WIRING METHOD IN METALLIC CONDUIT OR M.C. CABLE. � <br /> -Ffl� SINGLE POLE MOMENTARY SWITCH 48" LOW VOLT OCC SENSOR CONTROL <br /> 5. LIGHTING CONFORMS TO WASHINGTON STATE ENERGY CODE � DUPLEX RECEPT. 20" 180 VA EACH <br /> 51-11 C, CHAPTER 4 SECTION C405. <br /> �Fci WEATHER PROOF/GRD. FAULT 16" 180 VA EACH <br /> , 6. THIS PLAN IS NOT AN"AS-BUILT'DRAWING � QUAD PLEX RECEPT. 20" 360 VA EACH <br /> OS OCCUPANCY SENSOR CEILING LOW VOLT w/ POWER PACK <br /> QTY. SIZE DESCRIPTION Q LIGHT SENSOR CEILING 0-10V DIMMING CONTROL ' ' <br /> ONE-LINE-DIAGRAM � PHONE/DATA BOX 20°� STUB UP & DOWN w/ 3/4" <br /> ELECTRICAL PANEL 1 200 AMP 120/240V — SINGLE PHASE — STUB THRU — METALLIC RACEWAY SYSTEM 200 AMP FEEDER PANEL F�EX CONDUIT <br /> MAIN BREAKER � PULL STATION 48" <br /> 120/240 1 FIRE ALARM HORN/STROBE (INT) g4" 1/2° RACEWAY ONLY ' <br /> LIGHTING 3 2 x 4 TROFFER (3) T-8 32 WATT TUBES — 0-10V PROG DIMMING BALLAST � � PAINT SUBSTANTIALLY RED � <br /> 6 2 x 4 TROFFER (3) T-8 32 WATT TUBES — ELECTRONIC BALLAST 200 AMP � FIRE ALARM HORN/STROBE (EXT) 84" <br /> O THERMOSTAT 48" TO TOP OF J—BOX <br /> 1 72W LED FIXTURE w� PHOTO CELL 1/2" PVC 2" PVC STUB � PORCH LIGHT 84" 72 VA EACH <br /> STUB FOR BY BLAZER <br /> H.V.A.C. 1 3 TON 10 kW BARD WALL HUNG HEAT PUMP w/ ECONOMIZER FUTURE (2) 3/0 Cu THHN P� O PROGRESSIVE DFMMING BALLAS 88 A EACHEFIXTURELLAST � <br /> . GROUNDING (1) 1/0 Cu THHN CEILING <br /> THERMOSTAT 1 HONEYWEL� w/ MICROPROCESSOR— 7 DAY PROGRAMMABLE AND _ (1) #4 Cu 3 T-8 TUBE ELECT. BALLAST ' <br /> BONDING WIRE ON SITE BY OTHERS) � 24" x 48" TROFFER CEILING gg VA EACH FIXTURE <br /> VISIONPRO TH8320U AUTOMATIC SETBACK- DEADBAND CONTROL � <br /> g POWER PANEL 72" <br /> 2-1-16 ELECTRICAL ENGINEERING REVIEW ARS COPYRIGHT 2016, BLAZER INDUSTRIES, INC. � MODULAR Classroom for.� Approved for Const: Job No. 18567 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY <br /> OF BLAZER INDUSTRIES, INC.AND SHALL �� 28 X 32 KC DA - Eve rett S�D■ File Copy: <br /> NOT BE REPRODUCED, USED, OR DISCLOSED �� INDUSTRIES,INc. Drawn By: JwR � <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE WA. GOLD Pacific Mobile 14 BLMP-11 A3 Everett, �//� Issue Date: 02/01/16 <br /> DATE REVISION BY <br /> WRITTEN PERMISSION OF BLAZER INDUSTRIES. ■� P.O.BOX489 ■ Aumsville OR97325-0489 <br />
The URL can be used to link to this page
Your browser does not support the video tag.