Laserfiche WebLink
. •� . <br /> � ' ' <br /> , •:� . <br /> � #3 VIA PC3 �,3,5.7 O ' . � . <br /> #5 VIA PC5 GENERAL NOTES: � <br /> � � <br /> 1. WHEN STRANDED WIRE IS USED, ALL TERMINATIONS ARE MADE BY <br /> A PRESSURE TERMINAL, BY TAILING OFF WITH SOLID CONDUCTORS • <br /> (2) 8' x 4' WHITE BOARDS w/ 3 5 � ,.N,� OR OTHER APPROVED MEANS OF TERMINATION. <br /> MARKER TRAY (SHIP LOOSE) PCPCPC ELECTRIC <br /> INSTALLED ON SITE BY OTHERS PANEL 2. ALL CONDUCTORS ARE COPPER;TYPE THHN/THWN <br /> •; <br /> T O b t O b � O b 3. RATING OF STANDARD PANEL IS 22,000 A.I.C. . <br /> � _ � � - - - - - - - - - - - �— - - - - - - - - - - ---- #1 . � <br /> ( 4. WIRING METHOD IN METALLIC CONDUIT OR M.C. CABLE. `=` <br /> I � <br /> GFCI <br /> � #2�4 5. HVAC DISCONNECTS SHALL BE LABELED WITH AN IDENTIFICATION '�•.'' . . <br /> I PLATE SHOWING CIRCUIT NUMBER AND EQUIPMENT SERVED. <br /> � WAC 296-46B-1 10 022 ` <br /> � ONE-LINE-DIAGRAM <br /> I b. EXTERIOR WEATHER PROOF GFCI SHALL HAVE A"HEAVY DUTY" 100 AMP FEEDER PANEL . <br /> � _ _ _ _ _ _ _ _ _ _ � � _ � � WEATHER PROOF"IN USE"COVER. 2014 NEC 4069(B)(1) MAIN BREAKER <br /> C - - -. ,- - - - - - - - - - - --1-- <br /> 1 ( 120/240 1� <br /> I I 7. CONTROLLED RECEPTACLES SHALL BE LABELED PER 2014 NEC <br /> j O b O b 1 O b I I p P 406.3{E) WITH THE TEXT°CONTROLLED"AND THIS SYMBOL U 100 AMP �' <br /> O8. THIS PLAN IS NOT AN"AS-BUILT"CIRCUITS MAY BE RUN DIFFERENT <br /> nPP16 POWER THAN SHOWN BASED ON OBSTACLES ENCOUNTERED. 1/2" PVC 1-1/2" PVC STUB THRU � <br /> � PACK TO SIGNAL STUB FOR BY BLAZER <br /> I THERMOSTAT FUTURE (2) #2 Cu THHN <br /> I OCCUPIED PERIOD ' , . <br /> GROUNDING (1) #4 Cu THHN <br /> AND (1) �6 Cu ? <br /> I � 51-11C WAC 2015 WSEC CHAPTER 4 NOTES: � BON°iN� — (WIRE oN SITE BY OTHERS) <br /> � - - - - - - - - - - - ---� .-- - - - - - - - - - - - � �- - _ <br /> J � a _ <br /> a 1. ALL LIGHTING SHALL CONFORM TO SECTION C405 <br /> } O jO 1O S . • <br /> a a a � 2. BASE CLASSROOM uGHTING POWER DENSITY (C405.4.2.1) PANEL SCHEDULE <br /> " I 833 SQ. FT,x 1 WATT PER SQUARE FOOT= 833 WATTS ALLOWED �� <br /> I NOTE: ALL CONDUCTORS COPPER. 100 AMP 1� 22,000 AIC <br /> ADDITIONAL REDUCTION IN LIGHTWG POWER DENSITY (C406.3.1) <br /> � 833 WATTS ALLOWED (BASE) x .75= 625 WATTS ALLOWED CKT DESCRIPTION TRIP WIRE VOLT 'IOO VOLT WIRE TRIP DESCRIPTION CKT � <br /> NO. AMPS SIZE AMPS A B AMPS SIZE AMPS N0. - <br /> � TOTAL WATTS ALLOWED = 625 1 LIGHTS 20 �2 552 �� �� 7052 4 8o HVAC 2 <br /> I� TOTAL WATTS INSTALLED =477 WATTS 3 RECEPTACLES 20 12 1260 � � 7052 / / / 4 � • . <br /> 0 0 5 RECEPTACLES 20 12 1080 - - - - - SPACE 6 r • <br /> %OF ALLOWED 1NSTALLED = 76� <br /> 7 RECEPTACLES 20 12 900 �� �� - - - SPACE 8 <br /> O3. 100%OF LIGHTING FIXTURES HAVE EMBEDDED OCCUPANCY AND 9 SPACF — — — �� �� SPRCE �o <br /> DAYLIGHT SENSORS FOR INCREASED ENERGY SAVINGS, AND ARE 11 SPACE - - - �-� �� - - - s�ac� �2 . <br /> INDIVIDUALLY ADDRESSABLE. (C406.4) �3 SPACE — — — �� �~ — — — SPACE �q <br /> 15 SPACE - �� �� - - - SPACE 16 <br /> - 4. 100%OF LIGHTING IS SET FOR CONTINUOUS DIMMING AND IS �� SPArE - - - �� �\ — — — SPACE 18 ' <br /> ADJUSTABLE BY OCCUPANTS, FOR OCCUPANT COMFORT, VIA �9 SPACE - - - �� �� - - - SPACE 20 <br /> E L E C T R I CA L P LA N WALL PODS. (C406.4) - - <br /> 5. 50%OF RECEPTACLES ARE CONTROLLED BY LOCAL OCCUPANCY E L E C T R 1 C A L S Y M B O L S <br /> 1/4" = 1'-0" ARS 9/25/2017 SENSORS (C405.10) AFF ' <br /> SYMBOL DESCRIPTION TO TOP REMARKS r �+ ' • <br /> 6. THERMOSTAT OCCUPIED PERIOD WILL BE DETERMINED BY THE <br /> xx nLIGHT DIMMWG CONTROL DIMMING CONTROL. LOWER CASE ' <br /> nLIGHT OCCUPANCY SENSORS INTEGRAL TO THE LIGHTING '�'� SWITCH CAT5E CONNECTED 48 LETTERS DESIGNATE ZONING <br /> FIXTURES. <br /> H.V.A.C. (MOTOR, COMPRESSOR, HEATER SIZES) PC PLIUG LOAD2CONTROL RELAY CEIL�ING FIXTUR�LOCCU ANCY SENSORSED . <br /> OPERATION VOLTAGE 197 MIN. 253 MAX. <br /> COMPRESSOR 11.8 RLA 83 �RA ELECTRICAL PLAN REVIEW PP CONTROLPRELAYHERMOSTAT CBL�ING FI�TURELOCCBPANCIYHENSORSED <br /> �'s <br /> � OUTDOOR FAN 2.5 FLA 1�5 H.P. L�AD CALCULATIONS TR DUPLEX RECEPTACLE 180 VA EACH � <br /> INDOOR BLOWER FAN 2.8 FLA 1�3 H.P. � HALF CONTROLLED HALF HOT 20 TAMPER RESISTANT <br /> HEAT STRIP 10 KVA • <br /> VOLTAGE: 120/240 PHASE: 1� �TR QUADPLEX RECEPTACLE 20„ 180 VA EACH <br /> MINIMUM CIRCUIT AMPS 79 AMPS HALF CONTROLLED HALF HOT TAMPER RESISTANT <br /> MAXIMUM OVERCURRENT PROTECTION 80 AMPS NOTE: ALL DEVICES & FACE coNNECTE� �oA� CALC. LOAD a SINGLE RECESSED CLOCK 84�> 180 VA EACH < '.� ' <br /> OVERCURRENT PROTECTION- 6UAL ELEMENT TIME DELAY FUSE PLATES TO BE IVORY � LIGHTING HANGER RECEPTACLE <br /> OR HACR CIRCUIT BREAKER � <br /> EXTERIOR 75 VA x 125 % = 94 VA �c ci WEATHER RESISTANT GFCI <br /> RECEPTACLE 20" 180 VA EACH <br /> 1NTERIOR 477 VA x 125 % = 596 VA 4" SQ BOX SINGLE GANG MR WITH <br /> QTY. SIZE DESCRIPTION , PHONE / DATA BOX 20" 3/4" CONDUIT UP AND DOWN ' � <br /> ELECTRICAL PANEL � 100 120/240V - SINGLE PHASE - STUB THRU - METALLIC RACEWAY SYSTEM RECEPTACLES � FIRE ALARM PU�L STATION 48" .; <br /> THRU 10,000 3240 VA x 100 % = 3240 VA 4" SQUARE BOX w/ SINGLE GANG MUD <br /> 9 2 x 4 LED VO�UMETRIC TROFFER- nLIGHT ENABLED- 6000 LUMEN- 53 WATTS- 4000K FIRE ALARM INTERIOR RING - 3/4" RACEWAY STUB UP ONLY <br /> WITH EMBEQDED OCCUPANCY AND DAYLIGHT SENSORS COMMUNICATING ON CAT5E � HORN / STROBE 84 PAINT BOX, MUDRING AND RACEWAY <br /> UGHTING LOCAL NETWORK LITHONIA - BLT460LADPEZ1LP840N100NES7ADCX OVER �O,000 0 vA x 50 % = 0 VA , <br /> MOTORS, COMPR. � FIRE ALARM EXTERIOR "RED" IN COLOR <br /> HORN / STROBE 84 <br /> 1 72 WATT LED WALL PACK w/ INTEGRAL PHOTOCELL ECONOLIGHT E-WP11L07CZ / E-ACP1 TOTAL 4104 VA x 100 % = 4104 VA <br /> T THERMOSTAT 48» 4" SQ BOX SINGLE GANG MR WITH r•� � <br /> HVAC � 3 TON 10 KW BARD WALL HUNG HEAT PUMP w/ INTEGRAL ERV- 11 EER RATED �RGEST (2832) VA x 25 % = 708 VA O 1/2" CONDUIT STUB UP <br /> w/ MICROPROCESSOR— 7 DAY PROGRAMMABLE AUTOMATIC sErBacK— HEATING 10000 VA x 100 % = 10000 VA � LED WALL PACK 84" 75 VA EACH <br /> THERMOSTAT � BARD 8403-06� DEADBAND CONTROL — OCCUPANCY WTEGRATED INTO nLIGHT SYSTEM � <br /> 1 BARD CMC-29 FREEZE STAT O nLIGHT ENABLED LED TROFFER CEILING 53 VA EACH � � <br /> TOTAL KVA 17.90 TOTAL KVA 18.74 � w/ INTEGRAL SENSORS • . <br /> CO2 SENSOR 1 BARD 8403-067 - DEMAND CQNTROL VENTILATION CONNECTE� CALCu�ATED <br /> , LOAD AMPS 74.57 LOAD AMPS 78.�g B ELECTRICAL PANE� 72" •+ , <br /> 7-17-17 ELECTRICAL ENGiNEERING ARS COPYRIGHT 2017, BLAZER INDUSTRIES, WC: � MODULAR Classroom for.� Approved for Const: Job No: 19031 <br /> 9-25-17 REDUCED PANEL SIZE TO 100 AMP i ARS THIS MATERIAL IS THE EXCLUSIVE PROPERTY <br /> OF BLAZER INDUSTRIES, INC.AND SHALL ■■ File Copy: <br /> NOT BE REPRODUCED, USED, OR DISCLOSED • 28 X 32 KC DA - Eve rett S�D■ < �4 ' � <br /> �� INDUSTRIES,INC. <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE Drawn By: LDG � <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. �� `N`rvw.blazerind.com WA. GOLD Pacific Mobile 17 BLMP-04 A9 WA � <br /> �� P.O.BOX489 ■ Aumsvilie,OR97325-0489 Issue Date: 9-25-17 <br /> ' <br /> . .{ <br /> < ' ' <br /> � <br /> . i. <br />