Laserfiche WebLink
1 2 3 4 5 � <br /> GENERAL RACEWAY AND BOXES ONE-LINE DIAGRAM FIRE �►LARM SYSTEM (BIDDER DESIGN) DRAWING IIVDEX � � <br /> � � '.�_ EXISTING ELECTRICAL TO BE REMOVED � JUNCTION BOX EQUIPMENT ENCLOSURE F WP E-001 ELECTRICAL LEGEND AND DRAWING INDEX <br /> .7�� / O +��DEVICE SUBSCRIPTS (TYPICAL ALL SYSTEMS) E-002 ELECTRICAL ABBREVIATIONS AND GENERAL NOTES � . <br /> (WP,WG OR OTHER SUBSCRIPT) <br /> EXISTING ELECTRICAL TO REMAIN OF FURNITURE WALL FEED OUTLET BOX �m BUS �(NON-STANDARD MOUNTING HEIGHT) E-101 ELECTRICAL SITE PLAN <br /> � � <br /> NEW ELECTRICAL WORK PB PULL BOX ------ WIRE FACP FIRE ALARM CONTROL PANEL E-102 PARTIAL �L�CTRICAL SITE PLAN - PORTABLES ' <br /> � �WHERE INDICATED,SUBSCRIPT INDICATES PULL BOX TYPE) E-103 PARTIAL LOW-VOLTAGE SITE PLAN - PORTABLES <br /> � � � , <br /> �� MATCHLINE OR PROPERTY LINE HH HANDHOLE --a— TERMINAL/ LUG F�P FIRE ALARM ANNUNCIATOR PANEL E-301 ENLARGED PORTABLE FLOOR PLANS <br /> � �WHERE INDICATED,SUBSCRIPT INDICATES UTILITY VAULT TYPE) <br /> ENLARGED PLAN BOUNDARY —�— CONNECTION [�Q HORNISTROBE COMBINATION, WALL-MOUNTED E-701 ELECTRICAL DETAILS <br /> VAULT E-702 TELECOM DETAILS & RACK ELEVATIONS • " • • " " " ' " <br /> � �WHERE INDICATED,SUBSCRIPT INDICATES UTIUTY VAULT TYPE) ' ' • • •• ' '� � <br /> ' � xx Q DELTA � HORN/STROBE COMBWATION, CEILING-MOUNTED E-901 �LECTRICAL ONE-LINE DIAGRAM <br /> E1.1 DETAIL/PLAN IDENTIFIER � FLOORBOX �WHERE INDICATED,SUBSCRIPT INDICATES FLOOR E-"I OO� ELECTRICAL PANEL SCHEDULES . <br /> q BOX TYPE) � �/yE � STROBE ONLY, WALL-MOUNTED . <br /> /� POKE-THRU {WHERE INDIGATED,SUBSCRIPT INDICATES � • <br /> E1.1 SECTION IDENTIFIER OA POKE-THRU TYPE) � CURRENT TRANSFORMER � STROBE ONLY, CEILING-MOUNTED , <br /> � POWER POLE, FLOOR TO CEILWG n CIRCUIT BREAKER, FIXED � MANUAL PULL STATION � � � � ' � <br /> A Hargis�ngineers,Inc. <br /> ELEVATION IDENTIFIER <br /> E1.1 � SURFACE METAL RACEWAY �-- DISCONNECT SWITCH �s SMOKE DETECTOR 12Q1 7hird Avenue,Suite 600�Seattle,WA 98101 \. <br /> REVISION DEFINITION AREA, AREA ENCfRCLED t� 2Q6.448.3376 f��fl6.448.4450 w� hargis.biz <br /> CONTAINS CHANGES MADE SUBSEQUENT TO � RACEWAY CONCEALED IN WALL OR W CEILING � FUSED SWITCH ' <br /> (EXPOSED IN UNFINISHED AREAS) <br /> f-+ HEAT DETECTOR <br /> , P R E V I O U S (S S U E EiVGIN�ERS�MECHANICAL�ELECTRICAL•TELECOMMUNICATIONS • <br /> RACEWAY RUN BELOVI(FLOOR OR BELOW GRADE �I FUSE � MAGNETIC DOOR HOLD OPEN DEVICE <br /> � REVISION CALLOUT � . <br /> . , � , <br /> � FLEXIBLE RACEWAY /� MOTOR CONNECTION x SWITCH DEVICE . <br /> � FLAG NOTE TAG (F=FLOW SWITCH) <br /> �� RACEWAY (CIRCLE DENOTES VERTICAL � GENERATOR (T=TAMPERSWITCH) �� ' I <br /> TRANSITION) " �.s (P=PRESSURE SWITCH) <br /> ODEMOLITION NOTE TAG ' C <br /> X METERING DEVICE � RELAY <br /> C —� RACEWAY CONTINUATION (M=METER) <br /> 1O EQUIPMENT TAG (WH=WATT HOUR METER) <br /> ] RACEWAY STUB WITH BUSHING (A=AMMETER) <br /> (V=VOLTMETER) � <br /> aHu-o� MECHANICAL EQUIPMENT TAG (NYERCOM AND CLOGK �YSTEMS � <br /> [] RACEWAY SLEEVE WITH BUSHING �� . <br /> � ST SHUNT TRIP �'�«)�� <br /> N NORTH ARRQW � FIRE STOPPWG SLEEVE INTERCOM AND CLOCK, WALL MOUNTED <br /> � ' • � � • <br /> GF GROUND FAULT PROTECTION ANALOG CLOCK, WALL MOUNTED ' <br /> CABLE 7RAY, 12"W x 4"H OVERHEAD, UNLESB C ��(WHERE APPLICABLE WIRE GUARD) <br /> 0� LOCATION WHERE PICTURE WAS TAKEN AND OTHERWISE NOTED EPM ELECTRONIC POWER METER G C�sc�de H S 201 � <br /> DIRECTION -�c DIGITAL CLOCK, WALL MOUNTED <br /> CABLE TRAY, OVERHEAD LADDER TYPE SPD SURGE PROTECTIVE DEVICE <br /> � SPEAKER, CEILING MOUNTED Po rta b l e� <br /> HOMERUN TO PANEL �, `�iP�—(WHERE APPLICABLE IP SPEAKER W/TELECOM DEVICE) <br /> INDICATES PANEL DESIGNATION AND CIRCUIT NUMBER) _ GROUND SPEAKER, WALL MOUNTED <br /> POWER HA-3 � FO R ' <br /> � (WHERE APPLICABLE IP SPEAKER W/TELECOM DEVICE) <br /> 12 241 AVAILABLE FAULT CURRENT SYMMETRICAL TAG �"`� <br /> ' SWITCHBOARD/SWITCHGEAR #10 �_�GAUGE OF WIRE OTHER THAN AWG#12) � � � � SPEAKER EXTERIOR RATED, WALL MOUNTED � <br /> ,j �NUMBER OF CONDUCTORS 225 FEEDER TAG �P��"(WHERE APPLICABLE IP SPEAKER W!TELECOM DEVICE) �ve rett �'u b I i c <br /> (GROUND CONDUCTOR) <br /> � � PANELBOARD, FLUSH-MOUNTED (PHASE CONDUCTORS) —�B� EXTERIOR BELL, WALL MOUNTED �CI 1 C�O�� " <br /> (NEUTRAL CONDUCTOR) p <br /> ---- -- PANELBOARD, SURFACE-MOUNTED PAD MOUNT TRANSFORMER $�S CALL OR PANIC SWITCH, WALL MOUNTED <br /> � <br /> AT <br /> T (FRONT) GROUNDING $� VOLUME CONTROL, WALL MOUNTED <br /> TRANSFORMER o asov �01 E Casino Rd , <br /> � MOTOR CONNECTION TRANSFORMER �g DOORBELL, WALL MOUNTED Everett WA 98203 <br /> —G� GROUNDING CONDUCTOR zosv <br /> � 720V <br /> � DISCONNECTSWITCH, NON-FUSED �RouNORoo PERMIT RESU�MITTAL � <br /> - � TELECOMMUNICATIONS SYSTEM <br /> B �, DISCONNECT SWITCH, FUSED = 12/18/2019 g <br /> �---� GROUNDING BUSBAR PANELBOARD - MAIN LUGS ONLY . <br /> Q+ ENCLOSED CIRCUIT BREAKER TELECOMMUNICATIONS DEVICE This drawing is: � <br /> � EQUIPMENT GROUNDING CONNECTION (X=REPRESENTS THE#OF TELECOMMUNICATIONS MODULES) 1. COpyClght 2019 Dyk@I71ai1, IC1C. <br /> (W=TELECOMMUNICATIONS WALL PHONE MTD AT+4g��AFF) 2. The Architect's Instrument of Professional Service. , . <br /> vF� VARIABLE FREQUENCY DRIVE � GROUNDING STRAP (B=BLANK COVER PLATE) 3. For use on this project only. Obtain Architect's <br /> � written permission for any other use ar reproduction. <br /> MANUAL MOTOR STARTER WITH THERMAL <br /> (F=MODULAR FURNITURE DEVICE) <br /> $M ' PANELBOARD - MAIN CIRCUIT BREAKER Y (AC=ABOVE COUNTER DEVICE) _ _ s � <br /> OVERLOADS <br /> (S=SURFACE MOUNT) <br /> (WAP=WALL MOUNTED WIRELESS ACCESS POWT DATA DEVICE) <br /> �+ COMBINATION STARTER/DISCONNECT <br /> ABOVE CEILING TELECOMMUNICATIONS DEVICE ZO�) 9-02$ • <br /> , � MAGNETIC STARTER � (X=REPRESENTS THE#OF TELECOMMUNICATIONS MODULES) <br /> EQUIPMENT CONNECTION - CONFIRM CONNECTION WAP� I(WAP=WIRELESS ACCESS DEVICE) <br /> � �"`�(SV=SECURITY VIDEO CAMERA) � � <br /> WITH EQUIPMENT MANUFACTURER ��( MARK DATE DESCRIPTfON � <br /> FIRE RESISTANT 3/4" PLYWOOD BACKBOARD <br /> �Fis FIRE/SMOKE DAMPER TWO-POST EQUIPMENT RACK � <br /> � PUSHBUTTON CONTROLLER � . <br /> � (SINGLE OR MULTIPLE BUTTONS) 3.65" DOUBLE-SIDED VERTICAL MANAGEMENT <br /> EMERGENCY POWER OFF PUSHBUTTON � 6" DOUBLE-SIDED VERTICAL MANAGEMENT 1 , <br /> - � 12" DOUBLE-SIDED VERTICAL MANAGEMENT <br /> . . � , <br /> WALL MOUNTED ENCLOSURE . <br /> PRINCIPAL IN CHARGE: ( - � <br /> �� k!� FLOOR MOUNTED SERVER ENCLOSURE PROJECT MANAGER: � - � <br /> PROJECT ARCHITECT: � - <br /> � 110 BLOCK WITH LEGS JOB CAPTAIN: � - <br /> A � 66 BLOCK � - ' A . <br /> EL�CTRICAL LEC��I� D � � <br /> � AN � DRAWIN� IIV �EX <br /> m . � <br /> , <br /> NOT ALL SYMBOLS IVIAY APPEAR �N TWE DRAWINGS <br /> 1 2 3 4 5 � <br /> � . <br />