My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-41 2020-11-24
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-41
>
3003 W CASINO RD BLDG 40-41 2020-11-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/24/2020 1:20:19 PM
Creation date
11/24/2020 1:19:50 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-41
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
s A 2 A N Submittal Review <br /> GROUP <br /> DATE: 1/4/2019 <br /> SUBMITTAL NAME: Greenberry Submittal <br /> 40-41 Johnson Barrow CT Proposal Rev 3 <br /> Spec Section 23 6514.15 <br /> DATE SUBMITTAL 1/4/2019 <br /> RECEIVED: <br /> PROJECT NAME: 40-04&40-41 Cooling Towers Replacement <br /> SAZAN PROJ. NO. : 543-1898 <br /> REVIEWER: Patrick Du Gard, CPM, Sazan Group <br /> SIGNED: <br /> Review is only for general conformance with the design concept of the project and <br /> general compliance with the information given in the Contract Documents. Any action <br /> shown is subject to the requirements of the plans and specifications. Contractor is <br /> responsible for: Dimensions which shall be confirmed and correlated at the job site; <br /> fabrication processes and techniques of construction; coordination of his work with that <br /> of all other trades and the satisfactory performance of his work. A copy of this review is <br /> attached to and made a part of each copy of the submittal. <br /> to <br /> O <br /> Specification Q. <br /> Reference Description d , Comments <br /> L .c <br /> O O �ai s- <br /> z 0 a <br /> 23 65 14.15 Cooling tower frame X Verify all SS <br /> and fasteners. construction per <br /> specifications except <br /> PVC eliminators <br /> allowed. Verify no <br /> galvanized steel <br /> components. <br /> Proposal page Motor access door X Motor is to be mounted <br /> 1 of 3 external to unit with <br /> weatherproof cover. <br /> Access door is for <br /> 600 Stewart St.,Ste 1400 shaft. Correct wording. <br /> Seattle,Washington 98101 <br /> 2.12 Louvers/eliminators X Verify air inlet access is <br /> Tel 206.267.1700 hinged ss frame or <br /> Fax 206.267.1701 separate door at lower <br /> platform level <br /> sazan,corn <br /> Page 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.