Laserfiche WebLink
Sales and <br />Service <br />NOTES AND EXCEPTIONS: <br />This proposal is based on Spec sections 26 24 13 26 27 16 & 26 32 13 provided by City of Everett and drawings SWBD GSB2 <br />Rev2 WBD SSB-1 Rev1 SWBD SSB-2A Rev 1 SWBD SSB-2B Rev 1 provided by SAZAN. We know of no addenda, drawings, or <br />relevant spec sections. <br />#26 32 13 <br />2.8 E - Calcium Silicate Exhaust Insulation By Installing Contractor. Not Provided By Cummins <br />2.10 Oil Heaters Not Provided Not Factory Option <br />2 12 RTDs not provided on 1000 KW unit or 500 KW trailer. Not Factory Option- <br />#26 24 13 <br />1.5.A.1.b.6&7 — These drawings not available at submittal time. <br />1.5.A.1.c — Not available at submittal time. <br />3.1 — Installation by others <br />3.4 — By others <br />3.5 — By others <br />® Approval from the local utility MUST be obtained before this equipment may be connected, and/or operated with the facility bus. <br />• The price contained in this quotation is based on the sequence of operation either referenced to, and/or described in this document as <br />it pertains to the equipment indicated on the previous pages. Any variations to this sequence, and/or any additional circuit breakers, <br />switches, fuses, etc., to supply, monitor and/or control will require re -pricing. <br />• The supply <br />ting distributor. <br />® Engine/Generator control and monitoring, voltage regulation, paralleling, synchronizing, and some protective circuits will be <br />accomplished via PowerCommand TM Control and/or PowerCommand TM Paralleling. <br />1. The digital display on the PowerCommand genset paralleling control includes a synchroscope function for monitoring the <br />phase difference (in degrees, faster or slower than bus) between the generator set and the system bus. An indicator is provided to <br />advise the operator when the generator set is within specified paralleling parameters. <br />2. Paralleling control functions (synchronizing, load sharing, etc.) and paralleling protective functions (O/U bus voltage/frequency, <br />overload, and phase protection) are provided by the PowerCommand generator set controls that are resident on the gensets. <br />COVID 19 SUPPLEMENTAL STATEMENT <br />AS A RESULT OF THE OUTBREAK OF THE DISEASE COVID-19 ARISING FROM THE NOVEL CORONAVIRUS, TEMPORARY <br />DELAYS IN DELIVERY, LABOUR OR SERVICES FROM CUMMINS AND ITS SUB -SUPPLIERS OR SUBCONTRACTORS MAY <br />OCCUR. AMONG OTHER FACTORS, CUMMINS' DELIVERY OBLIGATIONS ARE SUBJECT TO CORRECT AND PUNCTUAL <br />S UPPLY FROM OUR SUB -SUPPLIERS OR SUBCONTRACTORS, AND CUMMINS RESERVES THE RIGHT TO MAKE PARTIAL <br />DELIVERIES OR MODIFY ITS LABOUR OR SERVICE WHILE CUMMINS SHALL MAKE EVERY COMMERCIALLY REASONABLE <br />EFFORT TO MEET THE DELIVERY, SERVICE OR COMPLETION OBLIGATIONS SET FORTH HEREIN, SUCH DATES ARE <br />S UBJECT TO CHANGE <br />INTERNATIONAL BUILDING CODE (IBC) CERTIFICATION <br />The products in this quotation identified as meeting the requirements of the 2009 IBC have been certified by their respective <br />manufactures via a combination of analytical testing and shaker table testing. Not all products have been shaker table tested. <br />OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENT (OSHPD) <br />OSHPD seismic requirements are continuing to evolve. Please contact Cummins for the most current requirements for meeting <br />OSHPD applications. <br />S ELECTIVE COORDINATION FOR NATIONAL ELECTRIC CODE (NEC) ARTICLE 700 AND 701 LOADS <br />Cummins generators are equipped with the manufacturer's recommended circuit breaker. Information regarding this device can be <br />supplied upon request. This quotation is not valid if any changes to this circuit breaker(s) is required to coordinate with other devices in <br />the electrical distribution system. If changes are required, the customer must provide a copy of the coordination study listing the <br />manufacturers part number of the disconnect device to be supplied with the generator and a revised quotation will be issued. <br />TRANSFER SWITCH WITHSTAND AND CLOSE RATINGS <br />Quotation: 0-129133-Q-07903 <br />Page 6 of 11 <br />Doc Ref: Q-07903-20201026-0951 <br />