Sales and <br />Service <br />Transfer switch(es), if included in this quotation, require a withstand and closing rating (WCR) capable of meeting the available <br />upstream fault current (kAIC). The WCR may be based on a specific breaker rating or a time -based rating, and it is the responsibility of <br />a qualified facility designer or engineer to verify compatibility. In the event that the proposed transfer switch(es) are not compatible, the <br />transfer switches) will need to be re -quoted to ensure compatibility. A full listing of the WCR can be provided upon request and will be <br />included as part of the submittal package. <br />CUMMINS STANDARD EXCLUSIONS <br />Exhaust System <br />All off -engine piping, hangers, flanges, gaskets, bolts, insulation, other materials and labor to install. <br />Fuel System <br />All fuel piping and materials not limited to; supply, return, venting, valves, coolers, filters, pumps, fittings, primary fuel regulator, storage <br />tank & senders, external to genset package. All fuel for testing and initial fill. Fuel tank vent extensions and flame arrestors unless <br />specifically listed in the Bill of Materials. <br />Cooling System <br />Intake louvers, exhaust louvers, air dampers, sheet metal ducting, flex adapters, sound <br />attenuators/baffles. All off engine piping, flexible connections, labor and coolant for remote cooling systems. <br />Electrical <br />All off -engine wiring, field terminations of wiring, and lugs other than those detailed in our submittal Mounting <br />Mounting bolts and anchors. Vibration isolators (if included) may be shipped loose for installation at the jobsite by others. Seismic <br />engineering calculations. <br />Electrical Testing <br />N ot limited to International Electrical Testing Association (NETA), infrared scanning, harmonic content or other independent agency <br />testing of switchgear, switchboards, protective relays, circuit breaker, electrical coordination studies, arc flash studies and reactive load <br />site testing. <br />Environmental Testing <br />Environmental Protection Agency (EPA), local air quality district or other Authority Having Jurisdiction <br />(AHJ), including acoustical. <br />P rogramming <br />All protective relay settings, breaker settings, PLC programming or other user configurable device programming. <br />Documentation <br />Electronic submittals and operation and maintenance manuals will be provided. Printed copies are available upon request, additional <br />charges may apply. <br />Miscellaneous <br />S ite specific labeling Exhaust backpressure, airflow restriction or vibration analysis <br />Design <br />Cummins is not responsible for system design or engineering and does not guarantee system performance standards. Cummins will <br />supply documentation and reasonable assistance to others responsible for system engineering, design and performance. <br />Taxes and Permit <br />Any applicable sales tax, permits, fees, licenses. <br />Bonds <br />Any bid bond, payment or performance bond or other type of bond. <br />All items listed above are excluded and will only be supplied by Cummins if agreed upon, in writing, by a sales representative <br />for Cummins. <br />P lease feel free to contact me if you require any additional information; or if you have any further questions or concerns that I may be of <br />assistance with. <br />Thank you for choosing Cummins. <br />S ubmitted by: <br />Cummins Sales and Service <br />N ame :Jeff Delauney <br />Email :hm656@cummins.com <br />Cell :(206) 660-5166 <br />Office:Cummins Renton <br />Quotation: 0-129133-Q-07903 <br />Page 7 of 11 <br />Doc Ref: Q-07903-20201026-0951 <br />