Laserfiche WebLink
Phase 5, Task 15: GraniteNet Integration & existing CCTV data migration <br /> Utilizing the methodology outlined above Timmons Group will design and develop the integration between <br /> GraniteNet and Cityworks. A second task within this integration is to migrate all historic CCTV inspection <br /> data so that an asset's past inspection history, condition scores, and video data are accessible <br /> within Cityworks making this information easier to find and available to more employees. <br /> Phase 5,Task 15.1: City Responsibility: <br /> • City will schedule and provide attendance at discovery workshop for integration functional requirements& <br /> design. (8-16 hours) <br /> • Review of design documents once designed (2-4 FTE hours) <br /> Phase 5,Task 15.1: Timmons Group Responsibilities and Deliverables: <br /> • Develop integration per functional requirements <br /> • Participate in project kick-off,planning, and configuration workshops hosted by CUES <br /> • Perform Cityworks configuration and XML modifications necessary to support integration <br /> • Support testing of integration <br /> • Develop Cityworks SOPs for integration workflows <br /> Phase 5,Task 15.1:Assumptions: <br /> ▪ CUES is responsible for installing, configuration, and training of their software. <br /> • The City uses or will deploy the GraniteNet Esri Interface and Import Module so that Granite is using the <br /> GIS as its asset repository the same as Cityworks. <br /> • City will provide review comments within 10 business days or a mutually agreed upon timeframe <br /> Phase 5,Task 15.1:Estimated Timeframe: <br /> • The development of the integration will require approximately 3-5 weeks <br /> Phase 5,Task 15.2: City Responsibility: <br /> • Review of design documents once designed (2-4 FTE hours) <br /> Phase 5,Task 15.2: Timmons Group Responsibilities and Deliverables: <br /> • Migrate CCTV inspection history for pipes from Granite to Cityworks. <br /> • Migrated inspection data shall include <br /> o Asset inspected(link to GIS asset if available) <br /> o Date inspected <br /> o Inspector name <br /> o Pipe condition scores <br /> Phase 5,Task 15.2:Assumptions: <br /> • City will provide review comments within 10 business days or a mutually agreed upon timeframe <br /> Phase 5,Task 15.2: Estimated Timeframe: <br /> • The migration of legacy CCTV data will require approximately 4-8 weeks <br /> Phase 5, Task 16: Cayenta Integration <br /> Utilizing the methodology outlined above Timmons Group will design and develop the integration between <br /> Cayenta and Cityworks. <br /> Phase 5,Task 16: City Responsibility: <br /> • City will schedule and provide attendance at discovery workshop for integration functional requirements& <br /> design. (8-16 hours) <br /> • Review of design documents once designed (2-4 FTE hours) <br /> Phase 5,Task 16: Timmons Group Responsibilities and Deliverables: <br /> • Develop integration per functional requirements <br /> • Sync GL Codes from Cayenta to Cityworks so the same code set is available for Cityworks users to pick <br /> from. <br /> • Sync Employee pay rates from Cayenta to Cityworks to keep pay rates up to date in Cityworks. <br /> Phase 5,Task 16:Assumptions: <br /> • City will provide review comments within 10 business days or a mutually agreed upon timeframe <br /> Phase 5,Task 16:Estimated Timeframe: <br /> • The development of the integration will require approximately 8-12 weeks <br /> 261P g <br />