My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3214 BROADWAY BROADWAY KINECT APARTMENTS 2021-08-11
>
Address Records
>
BROADWAY
>
3214
>
BROADWAY KINECT APARTMENTS
>
3214 BROADWAY BROADWAY KINECT APARTMENTS 2021-08-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2021 2:35:27 PM
Creation date
12/18/2020 2:52:33 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3214
Tenant Name
BROADWAY KINECT APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
551
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> •• American Property Development <br /> ES-0599.06 <br /> January 22, 2015 Page 11 <br /> • Updated June 9, 2016 <br /> • <br /> Foundations <br /> • Based on the results of our study, the proposed apartment complex can be supported on <br /> • conventional spread and continuous footings bearing on competent, undisturbed native soil. <br /> • Based on the planned excavations, we anticipate competent native soils suitable for support of <br /> foundations will be exposed at the foundation subgrade elevation. Where loose or unsuitable <br /> • soils are exposed at the subgrade elevation, the soil should be overexcavated and replaced <br /> • with a suitable crushed rock material. Crushed rock placed below foundations should consist of <br /> • one and one half inch to two inch clean crushed rock. <br /> • Assuming the foundations are supported on competent, undisturbed native soils or suitable <br /> • crushed rock material, the following parameters should be used for foundation design: <br /> • <br /> • • Allowable Soil Bearing Capacity 10,000 psf <br /> • • Friction 0.40 <br /> • <br /> • • Passive Resistance 350 pcf(equivalent fluid)* <br /> • "Assumes foundations backfilied with structural fill <br /> • For short term wind and seismic loading, a one-third increase in the allowable soil bearing <br /> • capacity can be assumed. A factor-of-safety of 1.5 has been applied to the friction and passive <br /> resistance values. <br /> • With structural loading as expected, total settlement in the range of one inch is anticipated, with <br /> • differential settlement of about one-half inch or less over the span of a typical column spacing. <br /> • The majority of the settlements should occur during construction, as dead loads are applied. <br /> • Slab-On-Grade Floors <br /> • Slab-on-grade floors for the proposed building structure should be supported on competent <br /> • native soil or a compacted structural fill subgrade, as appropriate. Unstable or yielding areas of <br /> • the subgrade should be recompacted or overexcavated and replaced with suitable structural fill <br /> • prior to construction of the slab. A capillary break consisting of a minimum of four inches of free <br /> • draining crushed rock or gravel should be placed below the slab. The free draining material <br /> should have a fines content of five percent or less (percent passing the #200 sieve, based on <br /> • <br /> the minus three-quarter inch fraction). In areas where slab moisture is undesirable, installation <br /> • of a vapor barrier below the slab should be considered. <br /> • <br /> • <br /> • <br /> • <br /> • <br /> • Earth Solutions NW,LLC <br /> • <br /> • <br />
The URL can be used to link to this page
Your browser does not support the video tag.