My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3214 BROADWAY BROADWAY KINECT APARTMENTS 2021-08-11
>
Address Records
>
BROADWAY
>
3214
>
BROADWAY KINECT APARTMENTS
>
3214 BROADWAY BROADWAY KINECT APARTMENTS 2021-08-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2021 2:35:27 PM
Creation date
12/18/2020 2:52:33 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3214
Tenant Name
BROADWAY KINECT APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
551
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> 6. Two-way communication should be shown at the landing serving the elevator on each <br /> floor that is one or more stories above or below the level of exit discharge. Section <br /> 1009.8 <br /> a. System requirements as specified by Section 1009.8.1 should be specified. <br /> b. Directions on the use of the system should be specified per Section 1009.8.2 <br /> 7. Raised character and braille exit signs should be shown at the exit stairways and exit <br /> discharge locations per Section 1013.4 <br /> Accessibility <br /> 1. A minimum of two van accessible parking stalls should be shown on the plans. Section <br /> 1106.5 <br /> 2. It should be verified that there is a minimum vertical clearance provided in the parking <br /> garage to and from the accessible van stalls. ANSI Section 502.6 <br /> 3. The accessible shower in Unit 643 should be shown with a shower seat. ANSI Section <br /> 608.2.2.3 <br /> 4. The accessible showers in the Type A units should be shown with thresholds in <br /> accordance with ANSI Section 608.6. <br /> 5. It appears that the toilet and bathing areas in the Type B units (all units other than Type <br /> A) follow Option B (one toilet and bathing area to comply with Section 1004.11.3.2). <br /> 6. The clear floor space should be shown at the bathing fixtures in the Type B units. <br /> Section 1004.11.3.2.3 <br /> Energy <br /> 1. Testing requirements of the envelope air leakage should be shown on the plans. WSEC <br /> Section R402.4.1.2 <br /> In order for the processing of your application to continue, it will be necessary to provide the <br /> Building Division with two new sets of revised construction documents reflecting the corrections <br /> requested. Please include a response letter which indicates how the corrections were resolved. <br /> All codes cited refer to the 2015 International Building Code (IBC), 2015 International Existing <br /> Building Code (IEBC), the 2015 International Fire Code (IFC), the 2015 International Mechanical <br /> Code (IMC), and the 2015 Washington State Energy Code (WSEC); as amended by the State of <br /> Washington and adopted by the City of Everett. The current IBC referenced standard for <br /> accessible design is the 2009 "Accessible and Usable Buildings and Facilities" (ICC/ANSI <br /> A117.1). Federal ADA regulations and standards may be more restrictive. <br /> These comments address building issues only. Additional revisions or additions may be required <br /> by other departments (such as Utilities, Traffic, Planning or Fire). All required submittals must <br /> be of sufficient detail and information to ensure that the proposed structure will be constructed <br /> in compliance with all adopted codes. <br /> Sincerely, <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425)257-8813 Page 3/d <br />
The URL can be used to link to this page
Your browser does not support the video tag.