My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3214 BROADWAY BROADWAY KINECT APARTMENTS 2021-08-11
>
Address Records
>
BROADWAY
>
3214
>
BROADWAY KINECT APARTMENTS
>
3214 BROADWAY BROADWAY KINECT APARTMENTS 2021-08-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2021 2:35:27 PM
Creation date
12/18/2020 2:52:33 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3214
Tenant Name
BROADWAY KINECT APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
551
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(7l9 <br /> Nevada: (702)365-9312 <br /> Idaho: (208)342-7168 Lochsa <br /> Colorado: (720)644-9246 engineering <br /> Alberta: (587)774-9040 <br /> 28 March 2018 <br /> City of Everett <br /> 3200 Cedar Street <br /> Everett, Washington 98201 <br /> ATTN: James Bronder, PE <br /> Subject: Broadway Ave. &32nd Street Apartments (Plan Check Number B 1710-41) <br /> Lochsa Number: 154191.00 <br /> Dear Mr.Bronder, <br /> Plan reviews are an important part of the building process and we look forward to resolving the <br /> issues brought forth by the plan reviewer. Please see summary of our responses to the structural <br /> comments indicated below: <br /> Note: All revised drawings should be marked with clouds and delta symbol 1 for `Addenda #1", <br /> dated 03/28/2018. <br /> Comment#2: It appears that the permit calculations are missing drift checks for the lateral <br /> design of the structure. Please provide these computations as well as checks <br /> for horizontal irregularities of the structure. <br /> Response: See the added drift calculations on sheets A3-A19 for the third <br /> and second floors of the concrete podium structure which are the <br /> conditions above grade. Based on our review of the drifts,we have <br /> concluded that we have an extreme horizontal torsional irregularity type <br /> lb.per Table 12.3.1 of ASCE/SEI 7-10. <br /> For the wood portion,please see added drift calculations on sheets A145- <br /> A147. Calculations are based upon worst case walls located on grids 1.5, <br /> 12,A,and F. Analysis is based upon flexible diaphragm force <br /> distribution. Upon review of Table 12.3-1,the only horizontal <br /> irregularity is Type 2,Reentrant Corner Irregularity. Diaphragm forces <br /> and connections were originally designed to take the additional 25% per <br /> 12.3.3.4. <br /> Comment#3: It appears that the ELF procedure ofASCE 7-10 Sec 12.8 is being used for the <br /> design of the lateral force resisting system. Please address how accidental <br /> torsion and the accidental torsional amplification factors are being accounted <br /> for in the design of the structure. Please provide support calculations are <br /> Lochsa Engineering www.lochsa.com 1-866-606-9784 <br />
The URL can be used to link to this page
Your browser does not support the video tag.