My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3214 BROADWAY BROADWAY KINECT APARTMENTS 2021-08-11
>
Address Records
>
BROADWAY
>
3214
>
BROADWAY KINECT APARTMENTS
>
3214 BROADWAY BROADWAY KINECT APARTMENTS 2021-08-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2021 2:35:27 PM
Creation date
12/18/2020 2:52:33 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3214
Tenant Name
BROADWAY KINECT APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
551
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 2 of 4 <br /> 6 Comment#5: It appears that the 9-factor for shear wall dowels and diaphragms were 0.75 on pages A59 <br /> and A60. Per ACI 318-14 Sec 21.2.4.1,a 9-factor of 0.6 is required unless the nominal shear <br /> capacity of the walls is greater than the shear corresponding to the development of the <br /> nominal moment capacity of the shear walls. Please indicate which 9-factor was used in the <br /> design of concrete shear walls as it is not clear in the design calculations provided.Also, <br /> please revise the 9-factors accordingly per AC1318-14 Sec 21.2.4.2 for the diaphragm if the <br /> 9-factor for the shear design of the shear walls have been updated. <br /> Response:Addendum 1 sheets A59-A64 have been revised using"-factors equal to 0.6✓ <br /> for the shear design of the diaphragms.See sheets B10-B15 for the revised calculations. <br /> A"-factor of 0.6,used to calculate the nominal shear capacity of the concrete shear <br /> walls,has been used in the shear wall calculations previously submitted.See added <br /> calculation sheet B16 for additional information. <br /> Comment#6: The response to the comment regarding using a perforated shear wall design indicates that a <br /> solid wall has a series of openings punched through solid wall. These walls, being part of the <br /> seismic force resisting system, are intended to be considered special concrete shear walls and <br /> subject to the provisions of ACI 314 18.10. These walls have individual wall piers between <br /> openings and beam-like elements that form above and below the openings. These wall piers <br /> and beam elements in the shear walls are subjected to the strength and detailing provisions <br /> per ACI 318-14 Sec 18.10.7 for coupling beams and Sec 18.10.8 for wall piers where the <br /> required, even if they are viewed as perforated walls. If these perforated walls are not <br /> intended to contain detailing for individual wall piers and/or coupling beams, it is assumed <br /> that the solid wall elements spanningfloor-to-floor are acting as shear walls. Please clarify <br /> and provide calculations and detailing for these wall piers or beam elements or indicate <br /> where full-height shear walls occur. Please update drawings, details, and shear wall <br /> calculations as required. <br /> Response:The RAM Structural System and RAM Concrete struc . analysis model, <br /> afar- <br /> and current typical wall reinforcing detailing shown on sheees into account <br /> ✓ the fact that we are utilizing a continuous concrete wall with the openings designed as <br /> perforations within a continuous wall. Our analysis also takes into account the design 7 <br /> -1)rD you Putt. requirements of ACI 318-14 Section 18.10 for the vertical wall segment design <br /> TWt. wtc a.c. r requirements.See added calculation sheets B17-B23 for information regarding Section <br /> 9wnrt-ivn i 18.10.8.In the cases where the wall segments are long enough to be designed as walls, <br /> wit, G d Tit <br /> j"' , the reinforcing requirements indicated in detail 2/4.03 also complies with Ordinary <br /> Boundary Element requirements per ACI 318-14 as 6 is less than 0.2 Pc. <br /> We have made revisions to detail 1/S4.03 extending the length of the tie spacing to <br /> extend 18"beyond the top and bottom of openings and revised detail 2/S4.03 to comply <br /> with Section 18.10. <br /> 'KR <br /> - l`El�- e . atc-^rtt <br /> Lochsa Engineering www.lochsa.com 1-866-606-9784 <br />