My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3214 BROADWAY BROADWAY KINECT APARTMENTS 2021-08-11
>
Address Records
>
BROADWAY
>
3214
>
BROADWAY KINECT APARTMENTS
>
3214 BROADWAY BROADWAY KINECT APARTMENTS 2021-08-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2021 2:35:27 PM
Creation date
12/18/2020 2:52:33 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3214
Tenant Name
BROADWAY KINECT APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
551
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,;�, RFI #190 <br /> i&ssis <br /> American Home Builders Inc. WAY APARTMENTS @ 3214 <br /> 110—110th Avenue NE,Suite 550 32ND&BROADWAY <br /> Bellevue,Washington 98004 EVERE Washington 98201 <br /> Phone: 1-800-635-0315 <br /> tt i 7 1 0 <br /> Nailing verification <br /> TO: David Sinnott(American P OPert 'OeVetopmsnt)"^ r Kasper Hechlacz(AMERICAN HOME <br /> BUILDERS,INC.) <br /> 110-110th Ave NE Suite 550 <br /> Bellevue, <br /> DATE INITIATED: 06/28/2019 STATUS: Open <br /> LOCATION: 3214 Broadway Everett Wa.98201 DUE DATE: 07/01/2019 <br /> PROJECT STAGE: Course of Construction COST CODE: 06-1063-ROUGH FRAMING <br /> SUB JOB: 19-CARPENTRY AND LUMBER SCHEDULE IMPACT: No <br /> COST IMPACT: No SPEC SECTION: 061000-Rough Carpentry <br /> DRAWING NUMBER: REFERENCE: Submittal 061 <br /> UNKED DRAWINGS: <br /> RECEIVED FROM: Wade Brown(WB Construction,Inc) <br /> COPIES TO: ..__ <br /> Wade Brown(WB Construction,Inc),DJ Homer(AMERICAN HOME BUILDERS INC.) <br /> Question from Kacper Hechlacz (AMERICAN HOME BUILDERS, INC.) at 11:57 AM on 06/28/2019 <br /> The current general notes section is stating that plywood nailing should be 10d-3"x.148.Our framer would like to get a confirmation that it is ok for <br /> him to use 10d 2 1/4"or 2 1/2"x.148 nailing on all 15/32 plywood and 23/32 plywood.This has already been approved per the submittal#61 but <br /> please verity and give us an approval in the RFI response so we can transmit it to Wade Brown.The proposed nailing is a common practice according <br /> to WB Construction. <br /> Awaiting an Official Response <br /> All Replies:. <br /> PER STRUCTURAL(PATRIC BIRD- EOR) REVIEW, PROPOSED NAIL SIZE IS APPROVED. <br /> CHP 7/2/2019 <br /> BY DATE COPIES TO <br /> American Home Builders Inc. Page 1 of 1 07/1 <br /> Printed On:07/01/2019 08:39 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.