Laserfiche WebLink
Click here for <br /> PAID Subscriptions <br /> • International Building Code <br /> o 12012(First Printing) l <br /> • Chapter 23 - Wood (ICC-ES Reports) <br /> • SECTION 2304 GENERAL CONS''RUCTION REOUIREMENTS (ICC-ES <br /> Reports) <br /> • 2304.9 Connectors and fasteners. (ICC-ES Reports) <br /> 2304.9.1 Fastener requirements. (ICC-ES Reports) <br /> 2304.9.2 Sheathing fasteners. (ICC-ES Reports) <br /> 2304.9.3 Joist hangers and framing anchors. (ICC-ES Reports) <br /> 2304.9.4 Other fasteners. (ICC-ES Reports) <br /> 2304.9.5 Fasteners and connectors in contact with preservative-treated and fire-retardant-treated wood. (ICC- <br /> ES Reports) <br /> 2304.9.6 Load path. (ICC-ES Reports) <br /> 2304.9.7 Framing requirements. (ICC-ES Reports) <br /> Top Previous Section Next Section To view the next subsection please select the Next Section option. <br /> 8 23049.1 Fastener requirements. <br /> Connections for wood members shall be designed in accordance with the appropriate methodology in <br /> Section 2301.2. The number and size of fasteners connecting wood members shall not be less than that <br /> set forth in Table 2304.9.1. <br /> TABLE 2304.9.1 FASTENING SCHEDULE <br /> CONNECTION FASTENING'', LOCATION <br /> 3 -8d common <br /> (21/2" x 0.131") <br /> 1.Joist to sill or 3 - 3" x 0.131" toenail <br /> girder nails <br /> 3 - 3" 14gage <br /> staples <br /> 2 - 8d common <br /> (21/2" x 0.131") <br /> 2.Bridging to joist 2- 3" x 0.131" toenail each <br /> nails end <br /> 2-3" 14gage <br /> staples <br /> 3. 1" x 6" subfloor 2- 8d common <br /> or less to each joist (21/2' x 0.131") face nail <br /> 4. Wider than 1" x 3 - 8d common -- <br /> 6" subfloor to each (21/2" x 0.131") face nail ��� <br />