Laserfiche WebLink
11/8?? to lOdd or 8de <br /> 11/4" <br /> 3/4" <br /> Single floor(combination and <br /> subfloor-underlayment less 6de <br /> to framing) 7/ " to <br /> 8de <br /> 1" <br /> 11/8„ to <br /> 11/ „ 10dd or 8de <br /> 4 <br /> 1/2" or 6df <br /> 32.Panel siding(to less <br /> framing) 5/8, 8df <br /> No. 11 gage <br /> 1/2" roofing nailh <br /> 6d common nail <br /> (2" x0.113" ) <br /> No. 16 gage staple' <br /> 33. Fiberboard sheathings 25 No. 11 gage <br /> / ��32 roofing nailh <br /> 8d common nail <br /> (21/2' x 0.131" ) <br /> No. 16 gage staple' <br /> 1/4" 4di <br /> 34. Interior paneling 3/8re 6dk <br /> For SI: 1 inch=25.4 min. <br /> a.Common or box nails are permitted to be used except where otherwise stated. <br /> b. Nails spaced at 6 inches on center at edges, 12 inches at intermediate supports except 6 inches at <br /> supports where spans are 48 inches or more.For nailing of wood structural panel and particleboard <br /> diaphragms and shear walls,refer to Section 2305.Nails for wall sheathing are permitted to be <br /> common,box or casing. <br /> c. Common or deformed shank (6d- 2" x 0.113"; 8d -21/2" x 0.131"; 10d - 3" x 0.148"). <br /> d. Common (6d -2" x 0.113"; 8d -21/2" x 0.131"; 10d -3" x 0.148"). <br /> e.Deformed shank (6d - 2" x 0.113"; 8d -21/2" x 0.13 1"; 10d -3" x 0.148"). <br /> f. Corrosion-resistant siding(6d - 17/8 " x 0.106"; 8d - 23/8 " x 0.128")or casing(6d - 2" x 0.099"; 8d <br /> -21/2" x 0.113")nail. <br /> g.Fasteners spaced 3 inches on center at exterior edges and 6 inches on center at intermediate <br /> supports,when used as structural sheathing. Spacing shall be 6 inches on center on the edges and 12 <br />