1110 <br /> • <br /> 4. Fire Suppression (Sprinkler)System-An approved automatic suppression system shall be <br /> provided as required by City Ordinance No. 3021-07, EMC, Chapter 16.76. <br /> Plans for any such system shall be submitted to the City of Everett Permit Services at <br /> 3200 Cedar Street 2nd Floor, Everett,WA for examination and approval.Such plans shall <br /> include plans for the underground mains that will supply the sprinkler system. <br /> The type of sprinkler to be installed will be determined by the Fire Marshall and Building <br /> Official. It may be an NFPA 13, NFPA 13R, or NFPA 13D system depending upon several <br /> factors. Sprinkler installation shall not begin without an approved and stamped set of <br /> plans from the City of Everett Permit Services.The Fire Department will also review the <br /> plans and shall field inspect the installation based only on approved plans that must be <br /> on site. Changes to plans must be approved by both Permit Services and the Fire <br /> Departments. <br /> Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA <br /> Standard 13. Underground piping shall be hydrostatically tested and flushed as <br /> • established in NFPA Standard 24 for private fire mains. (Below-ground piping must be <br /> installed by Washington State Licensed Underground Sprinkler line certified "U" <br /> installers. For further information, contact the State Fire Marshal's Office at(360)596- <br /> 3900 or contact the Everett Fire Department at(425)257-8120.)All such tests shall be <br /> witnessed by a Fire Department inspector. Call (425) 257-8120 to make an appointment <br /> for inspection. <br /> A weatherproof horn strobe and electric bell shall be added to sprinkler system. <br /> Contractors' materials and test certificates shall be submitted to the Everett Fire <br /> Department prior to issuance of any Certificates of Occupancy. 2015 IFC,WA State <br /> Amendment 903.3.5.3, Page 111. <br /> Call (425)257-8120 for more information. <br /> Need detailed notes on FDC and if Riser Room will change with expansion <br /> 5. The Snohomish County Emergency Radio System is employed by the City of Everett Fire <br /> Department emergency crews and operates at 800 MHz. Large metal-framed or metal <br /> and concrete buildings can weaken the signal so that communication and,therefore, <br /> firefighter safety is compromised.This structure must meet the requirements of EMC <br /> 16.03,Section 510,which specifically addresses required radio system performance <br /> standards in this structure.Your attention to this feature early in the planning stages <br /> will help avoid a costly,last-minute retroactive installation of radio signal <br /> amplification antennae and other equipment. For details,call the Everett Fire <br /> Department Plan Reviewer at(425) 257-8104. <br /> Revl 18-037 6 of 7� <br />