My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5818 GLENWOOD AVE A T AND T MOBILITY ANTENNA 2018-01-02 MF Import
>
Address Records
>
GLENWOOD AVE
>
5818
>
A T AND T MOBILITY ANTENNA
>
5818 GLENWOOD AVE A T AND T MOBILITY ANTENNA 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2020 8:56:57 AM
Creation date
12/29/2020 7:54:38 AM
Metadata
Fields
Template:
Address Document
Street Name
GLENWOOD AVE
Street Number
5818
Tenant Name
A T AND T MOBILITY ANTENNA
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
( : <br /> Tosver Aralysis F'eport July 20. 2012 <br /> 4 <br /> Carrier Site Num rer WA348 <br /> 4 Disclaimers <br /> Installation procedures and related loadirg are not within the scope of this analysis.A contractor experienced in <br /> similar work should perform all inslallation work.The engineering sarvices provided by Nickerson Engineering <br /> (NE) are limited to the calculations of the structure with the propos=d and existing/reserved loads indicated in this <br /> report.This analysis is considered void if the loadiny mentioned in this report is changed or is diHerent as <br /> installed. <br /> It is assumed that the existing structure is properly maintained and is in good condition free of any defects. Scope <br /> of this analysis does not include existing connections, except as noled in this report. NE does not make any <br /> warranties, expressed or implied in connection with this engineering analysis report anJ disclaims any liability <br /> arising from deficiencies or any existing conditions of the original structure. NE will not be responsible tor <br /> consequential or incidental damages sustained by any parties as a result of any data or conclusions included in <br /> this RepoR. <br /> It is the responsibility of the Client to ensure thal the information provided to NE and used in the performance of <br /> our engineering services is correct and complete. In the absence of information to the contrary, we assume that <br /> all structures were constructed in accordance with the dr�wings and specifications and are in an un-damaged <br /> condition and have not deteriorated: and we therefore assume that their capacity has not significantly changed <br /> from lhe"as new"condition. <br /> All services will be performed to the codes and standards specified by the client, and we do not imply to meet any <br /> olher code and standard requirements unless explicitly agreed to in writing. If wind and ice loads or other relevant <br /> parameters are to be different irom the minimum values recommended by the codes and standards, the Client <br /> shall specify the exact requirements. In the absence of information to the contrary, all work will be performed in <br /> accordance with the standards as specified in this report. <br /> All services are performed, results obtained, and recommendations made in accordance with generally accepted <br /> engineering practices and principles. NE is not responsible for the conclusions, opinions and recommendations <br /> made by olhers based on lhe information we supply. <br /> Antenna mounts; frames and other erroneous components have not been analyzed and are outside the scope of <br /> work of this analysis. <br /> - � i:,�..;r fr; <br /> .-;:�.�K�S..'.��r±��;,,w,�' . _ <br /> Nickerson Enginecring • 19�10 G�� LN NE, Kenmore. �VA 93028 • 206.679.4164 /C�/ _ � <br /> ( �j! <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.