REINFORCING PLAN NOTES �4j�'� <br /> PD <br /> Reinforcing and Post Tension Plan Notes: Ame�'�a�Pr°pe�y oe�e'°Pme��,'n�. <br /> 110110th Avenue NE suite 550 <br /> Bellevue,WA 98004 <br /> 1. For structural design notes, see sheet S0.02 thru S0.06. <br /> 1 2 3 4 5 6 7 <br /> 2. Architectural backgrounds are shown for reference only. ccoNsu�raNT'SLOGOANDADDRESS) <br /> 15�-�° I so�-o° 19�-s° Zs� -s° � �s�-s° Zs�-7° The dimensions shown apply to structural elements only. � � � <br /> For dimensions not shown, see architect of record submittal. <br /> v, n c7 - ,. � � i � c� <br /> � � 3. Contractor shall field verify existing structural conditions. If any 201 N. Maple Grove Ste. 100 <br /> � � � � � � <br /> discre ancies are found, contractor shall contact the Architect BOISE IDAHO 83704 <br /> �I p Phone(208) 342-7168 <br /> I , , I , , i , and Structural Engineer before performing alteration work. �E�oB# �5a�s�.00 <br /> ALL STRUCTURAL DETAII,$USED ON THIS <br /> PLAN ARE COPYRIGHT U OF LOCHSA <br /> I 4. F�r C��ur.1..�n SL•he,Ju�e See Sheet S'4.Q2. ENGINEERINGOFIDAHO.THERE-USEOF <br /> u ANY DETAILS AND CONCEPTS IS NOT <br /> I I � I ACCEPTABLE WITHOUT WRITTEN CONSENT <br /> - - - OF LOCHSA ENGINEERING Of IDAHO. <br /> A - - - �- - < a. -. - G _ - _ a -�°, _ � - " - - - - ° � 5. ast - West reinforci g shall be bottom most <br /> a a; _ . ; a. ,- _. _ 4. a a a , e : <.. e. a , a a . a. .Q For bottom reinforcing, E �n _ <br /> . o e <br /> 4 1/2" i 4 1/2° i 4 1/2" 4 1/2" 4 1/2"i 4 1!2° 4 1/2" 4 1/2" i � <br /> unless noted otherwise. <br /> I P M. H FN <br /> I � � <br /> - 16 i i oF asHi <br /> , I , 6. For top reinforcing, North - South reinforcing shall be top most unless o P�� Nc �, <br /> � noted otherwise. For concrete slabs reinforced with mild reinforcing � �:� <br /> 'v � 4 3/4" 4 3/4" I <br /> I i'i <br /> � 4 114' 4 1/4 4 1/2 4 1!2" 4 1/2" 4 1/4° ' I � only, provide 2�� clear to top most and bottom most reinforcing uno. � <br /> � � ' For post-tensioned concrete slabs reinforced with mild reinforcing and <br /> i ', I post tensioning tendons, provide 2" clear to top most reinforcing and `�'��L 3548� � � <br /> � , <br /> Fe=509.2K Fe=5092K ' 2 118" clear to bottom most reinforcing. °,� Rp� E" �� <br /> I � <br /> � - - <br /> B FSS�ONAL ENG <br /> - -- <br /> 4 1!2" 6 1/8" 6 3/4" 6 1/8" 3" 6 3/4" 6 1/8" 5" 6 1/8" 6 1/8"i 6 3/4" 6 1/8" 3" i 6" 4 3/4" 4 3/4" i 6" 3" � i 6 3/4" 7, For typical reinforcing details see S5.03 and S5.04. 03-�P.o,ro��zo2 <br /> e 'I � I For typical post-tensioning details see S5.06 thru S5.08. <br /> I 4 1/2" 4 1/2" I I I COPYRIGHT C�2605, AL�RIGHTS RESERVED <br /> ' ' ' ' 8. � Denotes opening in slab. For reinforcing around <br /> i � SUBMITTAL/REVISIONS <br /> openings at slabs reinforced with mild reinforcing only <br /> � � � ' � ' see 6/S5.04 and at post-tensioned slabs see4/S5.07 # DATE DESCRIPTION <br /> I I'� <br /> � unless noted otherwise on plans. � 03/28/18 ADDENDA#1 <br /> � I , <br /> ;r, � '�I 9. All bars between columns are centered on grids, unless noted <br /> - i 2 3/8" 2 3/8" 2 3/8"' 2 3/8" � 2 1/2" 2 1/2" i I � otherwise. <br /> N 2 3/8" i 2 3/8" ' <br /> � � <br /> j ' � � 10. For reinforcing layout at columns see 2/S5.04. For additional <br /> i , i i i <br /> , I information at mild reinforced slabs see 1 /S5.04, and at post- <br /> 'i tensioned slabs see 2/S5.08 and 3/S5.08 <br /> � ' ' � ' <br /> 9 �� � 11. In addition to all reinforcing shown on 3rd floor slab top and bottom <br /> I , 4 ��2" , � � reinforcing plans, see sheet S1 .11A and S1.11 B for additional <br /> 6 3/4 6 1!8" Fe=670K � <br /> reinforcing requirements at shear wall holdown anchors. <br /> C - - ° ' s v$° � '., - , <br /> a 4 1/2" 6 1/8" ( 7 1/2" 6 1/8" 3" � 6 3/4" 6 1/8" 3" 6° ' 5 1/2" 4 1/2" 4 1/2" 5 1/2" 6" 3" � 6 3/4" �2. • � � • Denotes slab reinforcing transition edges. <br /> i Fe=670K i 5 1/2" i � � ( � <br /> ; ' I 13. All P-T tendons shall be 1/2" in diameter, 7 wire strands, <br /> Fe=16K/FT � unbonded (sheathed) and shall be in conformance to ASTM A416. <br /> i i 4 1/2" i 1B i i I i <br /> - - _ _ _ _ _ � 5�� 5" � i 14. Fe=###k Denotes effective force for continuous banded <br /> � , , � post tensioned tendons (kips) after losses. <br /> I I � � <br /> Fe=16K/FT � I <br /> _ , 15. Fe-###k/ft Denotes effective force for distributed post tensioned <br /> °' � � ' - � � - - - - - - - <br /> � , - - - - - - - - - �/� <br /> a I , _ _ _ _ _ - _ _ _ _ _ _ _ _ _�,= tendons (kips/ft) after losses. }; <br /> °.-° M - 2 3/8" 2 3/8" 3�� I = - - 5�� � 4 1/2" 4 1/2"�- - - - � <br /> � V J <br /> � ; � � � ' ' � ' 16. �--� X" indicates dimension in inches from bottom of slab, <br /> � 2�3i$ �� � " excluding drop caps and beam, to center of gravity of '� <br /> � , , � � � � post-tensioned strands. See details on sheets S5.51 thru � <br /> I � 4�� 5�� 5�� I S5.53 for additional data. N <br /> ' � � � 17. Distributed tendon spacing shall not exceed 48" oc. � (n <br /> � I <br /> i Fe=670K - i i i i �e=670K i � � <br /> 4 1l2" 6 1/8" 6 3/4" 6 1!8" 3" 6 3/4" 6 1/8" 6 1!8" 6 3/4" 3" 6" 5 1/2" 4 1/2" 4 1/2" 5 1/2" 6" 3" I 6 3/4" 18. Added tendon profiles shall match main tendon profile, UtlO. <br /> D - - - _ _ - - . Q� <br /> , � 4 �i2�� � 6 ��s" ' I ' 19. Provide a minimum 2-post-tensioned tendons directly over columns in � <br /> � 6 3!4° � j � j each direction. For additional information see 2�S5.08 and 3/S5.08 > � Z <br /> I i � � I � � <br /> _ � � 20. Coordinate all drain, blockout locations, and quantity with arch. � � � <br /> �I <br /> , and mechanical. Blockouts shall not interrupt PT tendons and � � z <br /> ' ' � � �� � reinforcements, typ. For additional information see 4/S5.04, 6/S5.04 � <br /> � I � 4/S5.07 ,and7/S5.08 unless noted otherwise on plans. � � <br /> � I � <br /> � � Q <br /> , a 21. Post installed anchors in post-tensioned slabs are not allowed � <br /> N 2 3is° � 2 3�s° , 2 sis° s�� 2 srs°� 2 3is° � s° 3" � � � unless the required embedment of the anchor is 1" or less. � <br /> I <br /> � � <br /> , , � � 22. All piping and conduit are to be hung below concrete slabs. This � Q w <br /> � � ' includes but is not limited to drain lines, electrical conduits, and fire � s-- � <br /> � � � � sprinkler lines. Penetrations around columns are only allowed � � W <br /> - ' ' ' ' � I I where indicate in 4/S5.04. At penetrations near post-tension � � <br /> , � � anchors, see 7�S5.08, ° W <br /> � °- <br /> a 4 6 1/8" 3" 6 3/4" 6 1/8" ' Fe=5092K Fe=509.2K � <br /> z E _ - - ° <br /> - - 23. �- Denotes post tensioned dead end. <br /> o - -- < 1B i 6 118" 6 1/8" 5" i 6 3/4" 6 1/8„ 3" 6° � 5 1/4" 4 1/2" 4 1/2" 5 1/4" i 6" 3„ � i 6 3/4" <br /> � � � 24. -�" Denotes post tensioned stressing end. Q <br /> o, i i i � i <br /> c (Tendons shown as stressed from both ends shall <br /> o be pulled equally from each end. Q <br /> N I <br /> � o Fe=23.39K/FT � � <br /> E� -' � � ' ' ' � I � 25. Reinforcin between columns shall be centered and uniforml �^ <br /> a � `a 4 1/2" 4 1/4" 4 1/4" 4 1/2" 4 1!4"� 4 1/4" 4 1/2" 4 1/2" g y V J � <br /> � I � distributed between columns. O Q <br /> � � I Z � I <br /> �l W <br /> > - - � a. <br /> w _ . . , , . _ - ' • ' , a � " . _ ° 4 . ' " ., _ _ , a , ' p . .. _ _ _ _ d - - � � � <br /> ol � - ' d- '" . - " _ d - ' 4 ' _ , <br /> 0 <br /> � 4 1/2" 4 1/2" 4 1/2"II 4 1/2" 4 1/2" 4 1/2° � U � <br /> � , � , O O <br /> � ' � , � � <br /> o � i z � � <br /> N i i i , � J <br /> o� � � ' � <br /> � Fe=24.18K/FT Fe=24.7K/FT Fe=23.47K/FT Fe=21.44K/FT Fe=23.79K/FT Fe=20.96K/FT Fe=20.96KIFT � ~ � <br /> � H <br /> � � � 0 <br /> �� � <br /> Z � <br /> � <br /> � z <br /> E � Z <br /> � <br /> 3 <br /> N O H <br /> m O ~ � <br /> C ~ <br /> 3 W O = <br /> � (n r' (n <br /> � <br /> � <br /> J <br /> � <br /> O <br /> d <br /> y <br /> 2nd FLOOR POST TENSION PLAN - AREA A oRA� <br /> D AC <br /> > � 1/8" = 1'-0" <br /> w SHEET NUMBER <br /> � o S1 . 03G <br /> � � <br /> � Q <br /> � r <br /> U � <br /> 3 Qj <br /> � � <br /> � O <br /> � N <br /> O <br /> � N <br /> N('� <br /> FULL SIZE=24z36 <br /> HALF SIZE=12x18 <br />