Laserfiche WebLink
- _1 <br /> a�'`-"�+�„� <br /> REINFORCING PLAN NOTES �J�'" <br /> PD <br /> Reinforcing and Post Tension Plan Notes: a�»e���a�P�oPe�voe�e�oPme�t,�nc. <br /> 110110th Avenue NE suite 550 <br /> Bellevue,WA 98004 <br /> 7 $ 9 10 11 �2 1. For structural design notes, see sheet S0.02 thru S0.06. <br /> I 2. Architectural backgrounds are shown for reference only. �coNsu�TaNT'SLOGOANDADDRESS) <br /> , 28, _9„ , � 16, - s„ � The dimensions shown apply to structural elements only. <br /> 28' -7" 28'-9" 29'-7" � � <br /> For dimensions not shown, see architect of record submittal. <br /> �_. , � � ,� .� � � � , _ <br /> � � � ' ' 3. Contractor shall field verify existing structural conditions. If any 201 N. Maple Grove Ste. 100 <br /> BOISE IDAHO 83704 <br /> ' I discrepancies are found, contractor shall contact the Architect Phone(208) 342-7168 <br /> i � , � 1B i alld Stt'UCtUI'aI EClgllle@C' b@f01"e p@1"f01"CTlltlg alt2t"atlOCl WOt'I(. LE JOB# 154191.00 <br /> I i i <br /> a a e � . _ a . _ - - - - - - ^. For column schedule see sheet S4.02. - <br /> ALL STRUCTUR4L DETAI�USED N <br /> A a - PLAN ARE COPYRIGHT C OF LOCHSA <br /> d {d 6 � , � I' `� E ANIY DETAILS ND CONCEP SES NO OF <br /> _ - ACCEPTABLE WITHOUT WRITTEN CONSENT <br /> a � e 4 1/2" 4 1/2" 4 1/2° a a a 4 1/2" a a 4 112" 4 1/2" 4 1/2° ��2 5. F tJOtt ast - West reinforci g hall be bottom most oF�ocHsnENciNEERwcoFionHo. <br /> 4 <br /> or om reinforcing, E �n s <br /> - I � ' ' � unless noted otherwise. �P M. AHEN <br /> I � <br /> '� � � - uth reinforcin shall be to most unless P �� °� S"'�� <br /> , � , � <br /> � 6. For top reinforang, North o g p <br /> � � 4 1/8" 4 1/8" 4 1/8" 4 1/8" 4 1/4" 4 1/4" 4 1/4" 4 1/4" � �`P � � <br /> noted otherwise. For concrete slabs reinforced with mild reinforcing � �� <br /> I , only, provide 2" clear to top most and bottom most reinforcing uno. ��' � <br /> � � �� 4 For post-tensioned concrete slabs reinforced with mild reinforcing and <br /> � ` � <br /> I rovide 2" clear to to most reinforcin and �' L s' � � <br /> � ; �i _ post tensioning tendons, p p g 'P 3548 � <br /> - -- _ <br /> B � 6 3/4" 6 1/8" 6 1/8" 3" 6 1/8" � 6 314" 3" 6 1/8" 6 3/4" 6 1!8" 3" 6 1(8" 6 1/8" 6 3/4" 3" 6 1/8" 6 3/4" 1/ " 2 �/$�� clear to bottom most reinforcing. �,� RAL eN �� <br /> FSS�ONAL ENG� <br /> � � Fe=509.2K , � ; ° 7. For t ical reinforcin details see S5.03 and S5.04. 03-29-1 <br /> I I yp g EXP.01/07/202 <br /> ! � ° For typical post-tensioning details see S5.06 thru S5.08. <br /> I � � � COPYRIGHT C�2005, ALL RIGHTS RESERVED <br /> � � 8. � Denotes opening in slab. For reinforcing around <br /> � <br /> I o enin s at slabs reinforced with mild reinforcing only SUBMITTAL/REVISIONS <br /> � � . p 9 <br /> I � � see6/S5.04 and at post-tensioned slabs see4/S5.07 # DATE oEscR�PT�oN <br /> � I i unless noted otherwise on plans. � 03/28/18 ADDENDA#1 <br /> N � � 2 sis° 2 sis° 2 3is° 2 318° 2 3is° 2 sis�� 2 sis° 2 3i$" � � � a 9. All bars between columns are centered on grids, unless noted <br /> I � � ' otherwise. <br /> � <br /> � � 10. For reinforcing layout at columns see 2/S5.04. For additional <br /> � , � information at mild reinforced slabs see 1 /S5.04, and at post- <br /> I � , tensioned slabs see 2/S5.08 and 3/S5.08 <br /> � � <br /> � i 6 3/4" <br /> 6 3/4" <br /> 11. In addition to all reinforcing shown on 3rd floor slab top and bottom <br /> � � ' 4° ' � reinforcing plans, see sheet S1.11A and S1.11 B for additional <br /> a . . . <br /> C _ _ - - : - 4 �i2" � - - - - � ` reinforcin re uirements at shear wall holdown anchors. <br /> 6 3/4" 6 1/8" 6 1/8" 3" 6 1/8" � 6 3/4" 3" 6 1/8" i 6 3/4" 6 1/8" 6 1/8" i 3" 6 1/8" i 6 3/4" 4 1/2" g a <br /> � Fe=670K <br /> � � 12. • � � • Denotes slab reinforcing transition edges. <br /> d <br /> � ( <br /> � , i 13. All P-T tendons shall be 1/2" in diameter, 7 wire strands, <br /> � �� 4 1/8�� � Fe=23.s2wFTl unbonded sheathed and shall be in conformance to ASTM A416. <br /> � 4 1/8" 4 1/8 4 1/8" � � <br /> I I i 4 1/2° <br /> i � <br /> - - 14. Fe=###k Denotes effective force for continuous banded <br /> � � � � post tensioned tendons (kips) after losses. <br /> � � � � � <br /> � � _ � � _ _ - - - -- - - - - - - - - - - - � , 2 3i8�� � 15. Fe=###k/ft Denotes effective force for distributed post tensioned <br /> � - _ - - - - - -� - - - - - - - - <br /> � I � 5�� 5 3 tendons (kips/ft) after losses. ' <br /> o Fe=21.44K/FT <br /> �� <br /> I � ' � � 16. X-� X" indicates dimension in inches from bottom of slab, � <br /> ' excluding drop caps and beam, to center of gravity of � <br /> � - � <br /> � ' post-tensioned strands. See details on sheets S5.51 thru <br /> I � � <br /> 4 1/4" 4 1/4" 4 1!4" 4 1/4�� Fe-6�oK S5.53 for additional data. ^' <br /> i 6 3/4" d ` V <br /> � i � 4 1/2" . <br /> � 3�� M <br /> � 17. Distributed tendon spacing shall not exceed 48" oc. (n <br /> 6 3/4" 6 1/8" 6 1/8" 3" 6 1/8" 6 3/4" 3" 6 1!8" 6 3/4" 6 1/8" <br /> i - - - - - -_ � � <br /> D _ _ i - -- - -- - - 4 ��2��- - - - - 6 �i$" - - - - ` 18. Added tendon profiles shall match main tendon profile, uno. <br /> 4 1/2" ^, <br /> � 6 3/4�� `V <br /> � � � 6 3/4° � 4 19. Provide a minimum 2-post-tensioned tendons directly over columns in � <br /> � each direction. Foradditional information see 2�S5.08and 3/S5.08 � � z <br /> � , � � � <br /> I � �� � � <br /> I I 20. Coordinate all drain, blockout locations, and quantity with arch. � � <br /> I i , � � ; and mechanical. Blockouts shall not interrupt PT tendons and <br /> � � ' ! reinforcements, typ. For additional information see 4/S5.04, 6/S5.04 � � z <br /> � , 4/S5.07 ,and 7/S5.08 unless noted otherwise on plans. � Q = <br /> �, � � C� <br /> _' � Q <br /> 00 � 2 3/8" 2 3/8" 2 3/8" 2 3/8" 3" 3" 2 3/8" I � <br /> N 21. Post installed anchors in post-tensioned slabs are not allowed <br /> I ' � � '� � <br /> ( unless the required embedment of the anchor is 1" or less. <br /> � � <br /> � � � ' d 22. All piping and conduit are to be hung below concrete slabs. This W 0 W <br /> I � � <br /> includes but is not limited to drain lines, electrical conduits, and fire ; s- � <br /> I , , � � sprinkler lines. Penetrations around columns are only allowed � � W <br /> I ' Fe=509.2K where indicate in4/S5.04, At penetrations near post-tension o W <br /> � _ - _ anchors, see 7/S5.08. � <br /> - - - - ° . � � <br /> E � 6 3/4" 6 1/8" 6 1/8" 3" 6 1/8" 6 3/4" 3" 6 1/8" a 6 3/4" 6 1/8" 3" 6 1/8" d6 3/4" 3" 6 1/8" 6 3/4" 4 1/2"� <br /> � I I , i i � 23. �- Denotes post tensioned dead end. <br /> � I <br /> � ' 24. -�' Denotes post tensioned stressing end. m <br /> o � , � � ' �g (Tendons shown as stressed from both ends shall <br /> a o I � <br /> _ , p be pulled equally from each end. Q <br /> � � � 4 1/8" 4 1/8" 4 1/8" i 4 1/8" 4 1/4" 4 1/4" i 4 1/4" i �-- W <br /> �' � , � i 25. Reinforcing between columns shall be centered and uniformly �j � <br /> � distributed between columns. O � <br /> � � � � <br /> y 4 1/2" 4 1/2" 4 1/2" ri 4 1/2" I 4 1l2" 4 1/2" 4 1/2° ^ <br /> � - - - -a.a . 4 x Z I..L� 1 <br /> � - a d ' _ - . ' , . � / - 'e, ' . , . ' q " ' _ - • _ - d. _ _ . - _ " - " _' - - � <br /> y � - - __ - - � � � � � <br /> � OI I I i <br /> ' I � <br /> o U <br /> I � <br /> � o � J <br /> o ' ' z � � <br /> � � 16 -J <br /> o Fe=26.24K/FT Fe=26.24KlFT Fe=24K/FT Fe=23.1 K/FT Fe=23.3K/FT Fe=23.72KlFT � 7 <br /> ~ � L <br /> � Fe=26.24K/FT ? <br /> c � O <br /> o � <br /> N <br /> � � � <br /> � � � '^ <br /> �� �J J <br /> N � N z <br /> � U <br /> � <br /> �, o � W <br /> � � <br /> m o w <br /> � <br /> 3 w � x <br /> m �n c- �n <br /> � <br /> � <br /> � <br /> a <br /> a° DR4NM BY <br /> N <br /> � 2nd FLOOR POST TENSION PLAN - AREA B _ _ __ _ _-__ A <br /> � � 1/8" = 1'-0" <br /> ' SHEET NUMBER <br /> W <br /> m <br /> � � S1 . 0 <br /> � Q <br /> ; � <br /> � � <br /> U � <br /> � m <br /> � � <br /> N O <br /> � N <br /> O <br /> � N <br /> N (") <br /> fULL SIZE=24x36 <br /> HALF SIZE=12x18 <br />