Laserfiche WebLink
b <br /> f <br /> ZIMAIER GUNSLIL FRASCA PARTNERSHIP A.I.A. <br /> JOB NO.80467.08 Page 1 <br /> PEMC-DESIGN DEVELOPMENT 8/8/2002 <br /> MEMO TO: rony Lee/Everett Public Works <br /> FROM: Russ Brown/ZGF <br /> CC: File 1DECEOVE — <br /> n, <br /> SUBJECT: Plan Review No.B0206-022 <br /> -AUG 0 8 2002 J <br /> Project: Plan Review No. B0206-022 CITY OF EVERETT <br /> Colby Campus Backfill Permit Services <br /> 1321 Colby Avenue <br /> Everett,WA <br /> We have received your 7/17/02 comments and have found them to be very thorough and fair. <br /> Thank you for your time and patience. <br /> Below is our response to your comments. Many of your concerns are addressed in the <br /> Specification Manual that accompanies the drawings. We had submitted a copy with the <br /> drawings but will include another for ease of the review's sake. Please feel free to call me with <br /> any questions or concerns,or if there is any other information that you might need. <br /> Our response is categorized and numbered to match your review comments. <br /> General: <br /> 1. The architectural stamp was to have been inserted at the printers it apparently did not <br /> happen. We have corrected this on our current submittal. <br /> 2. It is our intention to submit all documents will to the Washington State Department of <br /> Health once all of the City of Everett's comments have been addressed and are accepted. <br /> 3. We have made contact with Mr.Tim Alaniz. Electrical drawings will be to him for his <br /> review. . <br /> 4. Structural calculations for the new window are included here in. Special inspections <br /> have been added to sheet A0.01 under Code Information. We have included only an <br /> inspection of the carbon fiber reinforcing. It is believed that given the limited scope of <br /> work involved that special inspections would typically not be required. The Owner <br /> would like to use Mayes Testing and Inspection as their inspection agency on this project. <br /> 5. Detail 2/A8.02 has been modified to match the structural reinforcing reflected in detail <br /> 4/A8.02. <br /> Occupancy: <br /> 1. Soiled Utility Room B329 is enclosed in a one-hour occupancy separation. <br /> 2. Utility Room Doors,B325,B329&C347,and their associated hardware have been <br /> changed to a required minimum fire rating of 60 minutes. Please see the modifications <br /> made to the attached Door Schedule. <br /> 3. Rooms B323,B341 &C309 are not intended be used for storage of combustible,or <br /> potentially combustible materials. Regardless Providence has elected to provide 60- <br /> minute doors at C309&C309A. Please see the modifications made to the attached Door <br /> Schedule&Floor Plan A2.3C. <br /> I�c <br /> 060802revicw.d« <br /> I • <br />